Loading…
Loading…
1,088 results • Latest
Supply of High Speed Diesel (HSD) Non Traction Confirming to IS: 1460 (Latest revision), through Road bowser facility for Power Car of Jaipur Division(Khatipura Railway station).
HIGH TENSILE RUSTLESS STAINLESS STEEL PIN (DIA 10MM) R.I. NO. 161-S CONFIRMING TO RE DRG. NO. RE/33/P/160 MOD-A & RDSO specification no. TI/SPC/OHE/ FASTENERS/0120 Rev. 1
Anti Creep Device for 10125 mm curved switches with ZU-1-60 thick web tongue rails B.G.(1673 mm) for 60 Kg (UIC) on PSC sleepers as per RDSO Drg. No. RDSO/T- 8782 &RDSO/T-8783 completewith fittings (including 27 mm dia. HTS Bolt with Nut to Drg. No. RDSO/T-8786 & RDSO/T-8787 andHardened packing plate to Drg. No. RDSO/T-8784 & RDSO/T-8785) ACD material shall be Structural Steelconfirming to the requirement of Grade E-350/BR of IS: 2062-2011 Indian Standard Hot Rolled Mediumand High Tensile steel - Specification (Seventh Revision). Notes : (i) The 27 mm dia HTS bolt and nut shallbe confirm to IS:3757 & IS:6623 and shall be manufactured by RDSO approved vendor for HTS bolts &nuts. The dimension of HTS bolts and nuts shall be as per drawing No. RDSO /T-8786 & RDSO/T-8787.These bolt and nuts shall be arranged and supplied by the suppliers /Tenderers . (ii) Hardened packingplate shall confirm to IS : 6649 and material 45C8 steel according to IS:1570 (Part 2). The dimension ofHardened packing plate shall be as per Drawing No. RDSO/T-8784 & RDSO/T-8785.
Digital Ultrasonic testing equipment for welded rail joint with LED/TFT screen Trigonometrical function and A-Scan storage along with data set up with mandatory accessories as per RDSO Specification No. M& C/NDT/129/2005/rev-II AUG 2014 , Version-03 dated 01.07.2015 or latest version RDSO approve .
CATENARY WIRE ENDING CLAMP (65) COMPLETE WITH ID NOS. 1121, 1092, 1094 & FASTENERS AS PER RDSO DRAWING No. ETI/OHE/P/1120 REV. B AND RDSO'S SPEC. No. TI/SPC/OHE/Fittings/0130(10/13) REV. 1
Donepezil 10 mg with Memantine 10mg Tab., Vitamin B Complex Syrup minimum100ml. Bottle & Vitamin B6 40mg. Tab./Cap.
Contact wire splice toothed type with fasteners as per RDSO assembly Drg - No ETI-OHE-P-1080 -1 Rev - B & part Drg no ETI-OHE-P-1081 - 1 Rev-C and RDSO'S specification No. TI/SPC/OHE/Fittings/0130(10/13) REV. 1 (Complete set of contact wire splice are consist of 02 Nos. contact wire splice part and 08 Nos. stud bolts.)
Disposable Sterile Crescent Knife (Bevel Up) 2-2.5mm (Alcon, BD, KAI, Sharp point
A drop-in charging adapter compatible exclusively with the surgical clipper's lithium-ion battery, allowing for an upright charging and storage position. The charger is designed to be easily wall- mountable and includes an indicator light to show charging status.
A disposable, Surgical purpose clipper blade with a width of 37.2 mm and a fixed cut height of 0.23 mm, designed to remove all types of body hair with a single pass while maintaining skin integrity. The blade is compatible with the BD surgical clipper handle and is suitable for both wet and dry conditions.
SMPS, INPUT RANGE-110V AC/DC WITH 30% VOLTAGE TOLERANCE, OUTPUT- 24VDC, for Electro pneumatic flushing System
RUBBER PART KIT FOR D-1 AUTO DRAIN VALVE CONSISTING OF 06 ITEMS WABCO PART NO. 05408282 SIL PT. NO. 30192900
FOUNDATION PAD FOR AUXILIARY COMPRESSOR TO DRG. NO. MEMU /4- CP- 004/D
Blow pipe cutter (cutting torch) fitted with PNM (for BMCG/LPG) cutting nozzle size-1/16 inch
Cam roller Air & Exhaust as per Drg.No. DLW Drg. No.TPE-16-0047 specn: DLW Pt. No.-10216844
FIXED BUSING - SKE-1380 ALT- ' B' DLW PART-NO. 10150845. as per Drg.No. SKE-1380 ALT- ' B' DLW PART-NO. 10150845. specn: SPECIFICATION NO. D- 40070.
25 KV Current Transformer (CT) 2 core PS class ratio 1500-750/5A as per RDSO specification No. TI/SPC/PSI/CT/0210(07/2021) with A&C slip 1 or latest.
PROTECTION COVER FOR PASSENGER EMERGENCY ALARM PULL BOX.
POWER CONTACTOR [WITH DIODE] FOR COMPRESSOR UNIT OF LHB TYPE AC COACHES, 3 POLE, RATED CURRENT- 32 A (AT RATED VOLTAGE & AC-3 UTILIZATION CATEGORY), RATED VOLTAGE- 690 V, COIL VOLTAGE 77-143 VDC, WITH SURGE SUPRESSOR, WITH 1 NC AUX CONTACT, CONFORMING TO RDSO SPEC NO. RDSO / PE / SPEC / AC / 0184-2015 (REV1), SUITABLE FOR LHB TYPE AC COACHES SWITCH BOARD CABINET [PLACE OF INTALLATION- S1K33, S1K34, S1K38, S1K39]. ACCEPTED MAKE & CAT NOS.: - AS PER SR. NO. 60 OF COMMON BOM OF RDSO LETTER NO. EL/7.1.108/MSSBC DATED 17.09.21 OR ANY OTHER MAKE WITH PRIOR APPROVAL OF RDSO.
Different types of tap set such as (1) HSS 3/8-16 inch UNC right hand threading tap set., Qty.-06 Set.(2) HSS 7/16-14 inch UNC straight fluted right hand threading tap set., Qty.- 04 Set.(3) HSS 5/8-11 inch UNC right hand threading tap set., Qty.- 04 Set. (4) HSS 5/16 inch BSW right hand threading tap set., Qty.- 03 Set. (5) HSS 3/8-16 inch BSW right hand threading tap set., 04 Set (6) HSS 7/16 inch BSW right hand threading tap set., Qty.-04 Set., Make- Totam, addition, tapria (each set has 03 Nos.)
Breather valve assembly with wire mesh filter for 10" bogie mounted brake cylinder
Mesh for lap Hernia Hydrogel base dual mesh for lap hernia with polypropylene and adsorable hydrogel suggested make Bard, J,&J, SI, Size 15x20 cm approx - US FDA/ BIS /ISO approved
System pack Reagent kit for Glucose (GOD POD method) for Fully Automatic Biochemistry Analyzer BA400(PACK SIZE 600 ml)
Port for Chemotherapy (Chemoport) MRI compatible 8 Fr single lumen venous catheter kit with dual valve mechanism
CIRCUIT BREAKER- 2 pole, 65 Amp., 74 VDC for Controlling of Computer in Siemens Controlled HHP locomotives to SIEMENS Pt. No. 102327844, or EATON Pt. No.- AM2R- B-2B3-LA-07-D-NU44-65-2 or AIRPAX Pt. No. IALHK11-71211-6.
System pack Reagent kit for Cholesterol, End Point for Fully Automatic Biochemistry Analyzer BA400(PACK SIZE 600 ml)
System pack Reagent kit for rheumatoid factor (RF) for fully AUTO BIO ANALYZ BA400(PACK SIZE 1X300 ML)