22 PIN UIC PLUG FOR AMRIT BHARAT COACHES AS PER CLW SPECIFICATION NO CLW/ES/3/0671 and drg no CLW/ES/3/SK-2/0671
AUTHORITY TO PASS DEFECTIVE SIGNAL,LIMP BOUND,SIZE 8.5 X 12 INCHES, PRINT IN BLACK INK BOTH SIDES, PAPER TO BE USED IS MAPLITHO 60 GSM. D.NOTE NO.T 369 (3b)
T57B (H/E) TABLE SIGNAL UP LINE TRAIN Size %u2013 17 x 12 inches, Books of 100 leaves
Supply of hydraulic crimping tool consisting head and foot Operated Pump, Suitable Crimp connecting Hose Pipe of minimum 2 Mtrs, Length to Crimp the cable of sizes from 25 Sqmm to 400 Sqmm, Supply shall be with standard accessories and crimiping Die Sockets of sizes 25,35,50,70,95,120,150,185,240,300 and 400 Sqmm as per spec.
7 INCH TFT LCD SCREEN FOR DOWNLODING OF FOOTAGE FROM CCTV IN LHB COACHES. SPECIFICATION AS PER ANNEXURE A. DEVICE SHOULD BE COMPATIABLE WITH EXISTING INSTALLED CCTV SYSTEM IN LHB COACHES
STRAP FOR AUXILIARY RESERVOIR & NUT WITH PLAIN & SPRING WASHER AS PER ICF DRAWING NO-DC/EMU/M-3-5-007 ALT-C OR LATEST.
LP PISTON DIA 106 WITH GUDGEON PIN. (INCLUDEING 4&5) TO ELGI PT NO. 000477710
SECURING BLOCK TO DRG-CGM/31403 REV-8. TO CGL MATERIAL CODE NO. 761041722 FOR TRACTION MOTOR TYPE-2141C USED IN DETC.
Inspection Gauge for CMS 1:12, 60 Kg T-4782 (4220)
HOSE CONNECTION FOR 3/8'' X2300 MM LONG TO ICF DRG NO ICF/SK-3-5-517, ALT- u/18 ,ITEM NO- 3. BOTH ENDS SHOULD BE SWIVEL END WITH 03 NYLON WASHER TO DRG. NO- ICF-SK-3-5-263.
Set of pneumatic tools , 5 inch pneumatic angle grinder - 08 Nos and 13 inch pistol type pneumatic drill machine - 08 Nos as per attached - A .
Paint ready mixed black color for Acid resistance(lead free) for battery boxes as per IS-159/81 Amendment-1 or latest.
SILICON OIL PRODUCT NAME AVI LUBE S-40 OF M/S AVI-OIL INDIA PVT.LTD. OR SILICON LUBRICANT 1609 OF M/S 3M OR XIAMETER PMX-200. OR SILICON FLUID 350 CST OF M/S DOW CORING OR SILICON 20-300.000,350 CST OF M/S MATRIX SPECIALITY LUBICANTS.
RUBBER PART KIT FOR C-3 W DISTRIBUTOR VALVE CONSISTING 45 ITEMS . DRG.NO.NDLA/ CX-169 ALT NIL
Isolating Cock 3/4 (with vent) as per Knorr Bremse Part No. II105104/2 of Make- Knorr Bremse, GEM Enginnering, Fluidteq or Similar.
Rubber Spring Plate to Schaku Drg. No. 40-586.06(2), Item No. 8 as per RDSO Specification No. 61-B-36/Rev-2.
50 mm Stainless Steel Ball Valve(Specification as per attached Annexure-A)
Brake Beam Safety Strap (Simplified) as per Drg. No. BW/E-378, Alt. Latest for MEMU Trailer Coaches
RELAY SR TO CONFORMING TO BHEL DRG No.35831030015P10 CS NO ACS 1252 OR BEIL DRG No. B358310300150 P10 SUITABLE FOR MEMU MOTORCOACH
Supply of items for traction motor TYPE-2141C used in DETC as per attached ANNEXURE-A.
4 MOTOR REVERSER 30 RPS2 WITHOUT MAGNET VALVE CONFORMING TO BHEL DRG. No. 0578103001 V00 CS NO AMT1208 FIG REF.0000. OR BEIL DRG/ PART No. B057810300010 V00 suitable for 1400HP DPC.
SET OF FASTENERS AS PER ANNEXURE-A FOR TRACTION MOTOR TYPE-2141C USED IN DETC (TOWER WAGON).
Manufacturing and supply of complete set of Inspection Gauges
Supply Testing and Commissioning of Oil filling Plant for Transformer and Power Converter as per enclosed annexure.
SS Worm Drive Hose Clip Size 45 mm to IS:4762/2002, Tab-1 and Material to AISI 304
Gear oil (EP-90), Specf.-EP type-5 Multipurpose Gear lubricants of Grade SAE-90 (Accepted Make/Brands- HPCL,IOC , BHARAT SHELL, BALMER LAWRIE ,BPCL, GULF OIL CORPORATION)
SET OF NUT BOLT CONSISTING OF 02 SIZES. 1. BOLT 9/16 - 18 X 3-1/2and 2. NUT HEX LOCK 9/16 - 18
Sterile Disposable Polymer coated Latex Powder Free Surgical Gloves IR Size 7.0 " in pair ISO APPROVED, ANATOMICALLY SHAPED with MICRO ROUGHENED SURFACE, Confirming to Quality standard ASTMD 3577, manufactured under GMP & ISO systems, should have non chlorinated gloves with certification, should have sterilization by gamma radiation or ETO.
COMPRESSION SPRING, SUITABLE FOR BELT TENSIONING DEVICE OF 25 kW BRUSHLESS ALTERNATOR, AS PER RDSO DRAWING NO. SKEL-3940 SHEET-I (ALT.-5) & SHEET-II (ALT.-5), ITEM NO. -6, AND CONFORMING TO RDSO DRAWING NO. RDSO/PE/SK/AC/0068-2004 (REV-0).
Sterile Disposable Polymer coated Latex Powder Free Surgical Gloves IR Size 7.5 " in pair ISO APPROVED, ANATOMICALLY SHAPED with MICRO ROUGHENED SURFACE, Confirming to Quality standard ASTMD 3577, manufactured under GMP & ISO systems, should have non chlorinated gloves with certification, should have sterilization by gamma radiation or ETO.
1. PROCUREMENT OF 20 G U/S FLARED TIP ( FOR 2.8 MM INCISION) MAKE ? OPTIKON 2000 SPA, ROME ITALY
"procurement of battery for ventilator model sv-300 make mindray"
PROCUREMENT OF consumables for Hamilton ventilator (Model hamilton C-3 NO- 9795,10659,9592) in ICU Hamilton hepa filter C-3 SKU-160216,QTY-03, HPO Inlet filter serv kit SKU-160497 -Qty-03
PROCUREMENT OF DERMA CHAIR WITH DERMA STOOL as per attach specification.
Automatic External Defibrillator(AED) as per attach technical specification
Paint synthetic enamel interior finishing smoke grey to ISC-692 to IS:5/2007 and IS:133/2013 part-1 amndt. No. 1. Additional requirement stipulated in ICF Specification no. ICF/MD/Spec/052 issue status 02 Rev-1.
Telecom work in connection with Provision of facility for TMC staff including transit accommodation & ancillary works for Track Machine staff & construction of RPF Barracks at BNLW and SIKR stations of Jaipur Division.