Porcelain Bracket Insulator (RI 6030-1) (1050mm CD) for 25KV, AC, 50 Hz,
Hose coupling for main compressor delivery as per ELS/VSKP Drg. No. ELS/VSKP/2019/12, Alt-A .
9 KVA, 750 V / 415 V / 190 V AC, 3 Phase [9 KVA, 750 V / 415 V / 190 V AC, 3 Phase, Star - Star - Star, Dry Type and air cooled power distribution transformer
Hand Driven Metal Body 1000V Analogue In [Hand Driven Metal Body 1000V Analogue Insulation Tester (MEGGER) with standard accessories and calibration certificate(NABL or any govt. approved agencies), Test Voltage : 1000 Volt, Measurement Range: 2000 M Ohms, Test Current: 2 Mili Ampere, Safety rating: Category III 1000 V of IEC 61010, Warranty 01 years. MAKE/Model: CIE 444 / WACO / Metravi / Meco / INDOTECH ONLY]
Supply and installation of Desktop PC - 3 years onsite comprehensive OEM warranty
Supply of Digital Master Pressure Gauge. [Supply of Digital Master Pressure Gauge. Range 0.00- 20.00 Kg per Square centimetre, Least count 0.01 Kg per Square centimetre. Display 15 mm high 5 full Digit Seven Segment customized LCD showing, Pressure Media SS- 304, Dia- 90 mm, Anodized Case. Equivalent to Vijay Make Model No TX-430 or its equivalent in R&D Instruments only. Firm s Offer: As above Make/ Brand :-R&D Instruments. HSN/SAC: 90262000. APG-20-STD- NV-bar.]
Supply, Installation & Commissioning of Portable Hand held X-Ray Fluorescence (XRF) Analyzer.
10 Sq.mm/1500 volts single core elastomeric cable
Provision of Integrated Passenger Information System (IPIS) at Tiruchchirappalli Junction (TPJ) station
CTR (P) for a length of 60.902kms by PQRS / SQRS and 1.803kms by manual in SSE/Pway/VPT & TN sections.
SSE/P.WAY/MG/MDU section - Proposed Annual maintenance of track between MDU-KQN stations and of MDU-TPC stations in MDU-DG and MDU-MNM engine run sections respectively in SSE/P.Way/MG/MDU section under ADEN/Central/MDU jurisdiction for one year
ADEN/Central Sub division:- (I):- Proposed Conversion of SWP into LWR for a length of 10.967 km at various station yards in SSE/Pway/ BG/MDU,MG/MDU,MNM & ADPT section. (II):-Through Fittings renewal (Plain track) of Main line in SSE/Pway/MG/MDU & MNM jurisdiction. (III):-Through Fittings renewal (Plain track) of Loop line and other lines at various station yards in SSE/Pway/BG/MDU,MG/MDU,MNM & ADPT jurisdiction. (IV) Through Rail Renewal (Secondary) for a length of 2.445 km at various loop lines in Madurai station yard. (V) Deep screening by Ballast Cleaning Machine for a length of 31.00 km at isolated locations between Km:-439.300 to 482.800 on UP Main line in between station DG-SER in SSE/P.way/BG/MDU section."
Madurai Division :- ADEN/SCT Sub-Division:- Provision of Track machine siding at 2 stations.(TML & KUV-Permanent way portion only )
Dindigul-Madurai (Up line) section:-Maintenance of Ambaturai cutting from km 447 /000 to km 449/900 in between Kodaikkanal Road - Ambaturai station for a period of one year in Senior Section Engineer / Permanent way/BG/Madurai section.
Periodical painting of FOB's in ADEN/SCT subdivision
Manpower Outsourcing Services - Man-days based - Others; Unskilled; Sweeper, Manpower Outsourcing Services - Man- days based - Others; Unskilled; Mali/Gardner Helper, Cleaning, Sanitation and Disinfection Service - Outcome Based - Office/Commercial/Institutions/Residential; Deep Cleaning; Indoor, Pest and Animal Control Service - Maintenance Contract; 1 month; Rodent Control, Pest and Animal Control Service - Maintenance Contract; 1 month; Vector Control (Mosquitoes/insects)
Pin Up Notice Board (V2) (Q3)
Respiratory Protective Devices - Full Face Masks Conforming to IS 14166 (Q3), Protective Eye Goggles (MHA) (Q3)
Circular Sheathedwith Flexible Conductor (V2) ISIMarked To IS694 (Q2)
Allin One PC (V2) (Q2)
Set of Insulating bush 08 x 10.00 high insulation hard epoxy fibre for Temperature sensor assembly of Traction Motor type 6FRA6068.
Proximity sensor ,Model IQHBD_PS_1v1, 50 mm sensing range
Supply of Residual Current Circuit Breaker with Overload (RCBO) 16A, 4 pole.
Straight metric metal thread end fitting
GALVANISED MILD STEEL TUBES ELECTRICAL R
4 core, 0.75 Sq.mm, Highly flexible,screened control cable
Cotton Yarn Waste (V2) as per IS 5485 (Q3)
Rubber Joint Packing for 10mm as per ICF Drg No.DC/EMU-3-5-033, Item No.23, , Alt.Latest
4 Sq.mm/1500 volts single core elastomeric cable to RDSO specification E 14/01, (Part II) Revision II of 1993,with Amendment Nos. 1, 2, 3 and 4. Firm's offer : As above, Make / Brand - APAR.
Manual metal ARC welding Electrode class N1 to size 4 X 350mm As per RDSO Specification No.IRS-M-28/17. Firm's offer : Same as above. Make/Brand : PRIMA CUT ALLOY/VARUN ELECTRODES PRIVATE.
Locking Pin Assembly as per Drawing No. RDSO/CG/DRG/24003 Conforming to specification No. RDSO Specification No. RDSO/2011/CG03(Rev.-03), Amendment No.1 (July 2024) Firm's offered Make:JGE
VB Trainset Amit make HVAC spare Filter Drier for Vande Bharat as per RDSOspecification no.RDSO/PE/SPEC/EMU/0196-2019 (latest) along with latest Annexureand Addendum/Corrigendum to M/s.Amit item code
OVERHAULING KIT FOR 8 INCH X 8 INCH BRAKE CYLINDER TYPE UAH CONSISTING OF 7 ITEMS TO DRG NO SR-LW-2-19-11 ALT-1. (1) STRAINER ASSEMBLY- 1 NO. REF NO 9. (2) PISTON HEAD DISC- 1 NO. REF NO 11. (3) ANTI-
ARISTO HDPE Pole-Mounted Outdoor Dustbin Brand: ARISTO (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687777244420 dt.24/06/2026)
VB Trainset Amit make HVAC spare Differential Pressure Switch (50-500 PSI) asper RDSO specification no.RDSO/PE/SPEC/EMU/0196-2019 (latest) along with latestAnnexure and Addendum/Corrigendum to M/s.Ami
Dust Bin for LHB coaches to Drg. No. C&W. LGD. SK. No. 1091.
POWERWIN 10A Modular Piano Type Domestic Switch Brand: POWERWIN (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687732225816 dt.20/05/2026)
Miniature Circuit Breakers (MCB) for AC Operation Marked To IS/IEC 60898 (Part 1) (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No
Pliers, Pincers and Nippers as per IS 2615, IS 11526 (Q3) MSE Relaxation for Years Of Experience and Turnover Yes | Complete Startup Relaxation for Years Of Experience and Turnover Yes | Complete
Custom Bid for Services - Eddy current array testing of 4212 wheelsets of LHB coaches at Coach Care Center TPJ and Coaching depot VM for a period of three years including GST at the rate of 18 percentage Similar Category Selection of Laboratories for Testing of Products/Material
Zonal contract (Works) - Execution of piece meal works and supply of materials in Palakkad division for a period of One year from 01.07.2026 to 30.06.2027 - Zone A-I - Senior Section Engineer/Permanent Way/East/Palakkad from km 510/07 Walayar(excl) km535/00-Palakkad (incl) - km.53/07 Palakkad Town(incl) km.58.13 Palakkad (incl).