Loading…
Loading…
58,463 results • Best match
ELECTRICAL WORKS
Renewal of Electrical installations, fittings, fans and power mains of the Surgical Block at Kilpauk Medical College Hospital, Kilpauk, Chennai-10
Renewal by Supply and fixing of 250 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with PWD earthing.
Supply, Installation, Testing and Commissioning of Electrical Installation work in various labs including associated works in Academic Complex at IIT Delhi
Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color matching) 3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. [DSR - 2025 (1.5)]
Operation and Maintenance Of Electrical Systems/Electrical Installations - Electrification Work as per TS NO 1655 TO 1660 & 1654 DATED 05-07-25
Operation and Maintenance Of Electrical Systems/Electrical Installations - Electrification Work as per TS NO 1655 TO 1660 & 1654 DATED 05-07-25
Operation and Maintenance Of Electrical Systems/Electrical Installations - Electrification Work as per TS NO 1661 TO 1666 & 1654 DATED 05-07-25
Operation and Maintenance Of Electrical Systems/Electrical Installations - Electrification Work as per TS NO 1661 TO 1666 & 1654 DATED 05-07-25
RMO of electrical and mechanical installations on PWD roads in East Delhi under EMD M-253, Delhi Electrical work in creation of additional office space of East Road/M-212 under Akshardham flyover and other misc. works in various offices.
eTendering System Government of NCT of Delhi Created By: Sunil Kumar Tayal Created Date/Time: 19-Jan-2026 03:20 PM Tender Title: RMO of electrical and mechanical installations on PWD roads in East Delhi under EMD M-253, Delhi Electrical work in creation of additional office space of East Road/M-212 under Akshardham flyover and other misc. works in various offices. Tender ID: 2026_PWD_284621_1