Loading…
Loading…
59,349 results • Best match
Lightning Arrestor Electrical work
OD20715/2025-2026:Supply of Hot Dip Galvanized earthing conductors of the following sizes conforming to DIN EN 62561-2 (VDE 0185-561-2), VDE 0185-305 (IEC 62305) having Zinc coating greater than or equal to 500 g/m2 (approximately 70 micrometre in mean value) and laying in existing earth excavated or built up trenches, clamping in trays, walls, racks, risers, trusses etc. using heavy duty Aluminium / GI Flats of which spacing between 35cm to 65cm and pulling through pipes including all minor civil works, including connecting / terminating with necessary welding, grinding and finishing with paint/abrasives etc. or existing Stainless Steel bolts, nuts, round and spring washers as per Electrical Inspectorate and IS Standards etc. complete as required. 30 mm x 3 mm GI Strip
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for electrification work including installation of poles and centralization up to transformer for Gram Panchayat Sitalaha to Vishwakarma and Sahu Basti Vi..
Operation and Maintenance Of Electrical Systems/Electrical Installations - NIT Schedule of Item for electrification work including installation of poles and centralization up to transformer for Gram Panchayat Sitalaha to Vishwakarma and Sahu Basti Vi..
GENERAL-Balance work for construction of new building for Govt.UPS Jawahar colony, Palode-Balance work-Electrical works-General Electrical Work
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
ARMO various electrical and mechanical installation at AGMP Audit and Account office building Gwalior SH: supply and laying cable tray and fire hose reel Subwork/Packages: work
1 Electrical work 572288 Above 3.6 592890.368
Electrical
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
INVITING RATE FOR ALL KIND OF REPAIRING AND CONSTRUCTION WORK UPTO 1.00 LACS BASED ON MPUADD ISSR 02.08.2021 ELECTRICAL WORKS SORS FOR ELECTRICAL WORKS
INVITING RATE FOR ALL KIND OF REPAIRING AND CONSTRUCTION WORK UPTO 1.00 LACS BASED ON MPUADD ISSR 02.08.2021 ELECTRICAL WORKS SOR’S FOR ELECTRICAL WORKS