Loading…
Loading…
6,462 results • Best match
Electrical work connection to 1.Provision of Interlocking LC gates irrespective of TVU on account of Restricted visibility in BSB Division with RTU & Power Supply arrangement (Total 08 No. LC).2.Provision of Interlocking of LC gates having more than 20000 TVU under jurisdiction of SrDSTE I BSB with RTU & Power Supply arrangement (BNRS-HDT-7C, GYN-BYH-42A B2, GYN-BYH-46A B2 & BYH-HDK-49B B3) (Total 04 No. LC).3.Provision of Interlocking of LC gates having more than 20000 TVU in BSB Division with RTU & Power Supply arrangement. (DDA-MHC-4C & MAU-SHG-31C) (Total 02 No LC).4.Provision of Interlocking of LC gates having more than 50000 TVU in BSB Division with RTU & Power Supply arrangement (SQW-RTU-35 Spl & POU-KKT-64 Spl) (Total 02 No. LC)
Description:- Supply, Fabrication and erection of fabricated structure of angle iron 35x35x5 mm /
Design, Supply, Installation, Testing and Commissioning of entire pipeline System from MPH to S-4 and from S-4 Pump House to connected branches sprinkling System and automation using of Self dynamic Hydro Control Val
Supply and placing of the design mix concrete corresponding to IS -456 using WEIGH BATCHER/MIXER using 20 mm size graded machine crushed hard granite metal (coarse agggregate) from approved quarry including cost and conveyance of all materials like cement,fine aggregate(sand),coarse aggregate ,water etc to site and including seigniorage charges ,sales and other taxes on all materials including all operational ,incidental and labour charges such as weigh batching ,machine mixing ,laying concrete ,curing etc complete but excluding cost of steel and its fabrication charges for finished item of work (APSS NO 402) with minimum cement content as per IS Code from standard suppliers approved by the deparment including pumping , centering,shuttering,laying concrete ,vibrating, curing etc M20 design mix unit 1.00cum a) 300mm & 200mm main line Support Bends
WELCOME PERIODICAL SERVICES AND CERTAIN MISC WORKS IN MD OFFRS JCOS ORS ACCN IN A A BANAR UNDER GE BANAR
Material & labour for fabrication of pressed steel cupboard shutter using 1mm thick MS plain sheet with frame 1.25mm thick bent to shape including two coat of synthetic enamel paint on internal surfaces & two coat of hammer tone finish on external surface alongwith locking arrangement mortice lock ,handle etc complete all as specified as per drg No CEJZ/TD/12/2008 sheet 1/3 to 3/3.
Attached
33 KV Isolator without earthing Blade (33 KV, 1250 A Outdoor 3 Pole 25KA alongwith fabrication laying MS Steel as per REC Standard)
PROVIDING AIR CONDITIONERS IN DHARAMSHALAS OF VILLAGE KHUDA LAHORA AND KAIMBWALA, CHANDIGARH
Fabrication & erection of steel shutters for electrical niches as per following specifications FRAME: The shutter of suitable dimensions for electrical nitch shall be made out of 16 G.M.S. sheet. The shutter frame shall be 1-1/2”x1-1/2”x1-1/2” channel frame 4 Nos. ‘L’ type holdfasts for fixing the same on the wall. The size of the shutter frame should be suitable for 2Nos. door panels/single panel depending upon the size of nitches DOOR PANEL: The door panel shall have support in U-Shape formation made from 16G.M.S. sheet with 4”x3/4”M.S. channel duly spot welded to give additional strength. The door panel shall be fixed with frame with the help of concealed M.S. hinges of suitable size having good strength. The door panel shall be provided with a bolting arrangement either of Godrej type or such type so as to interlock the door panel with frame. The handle shall be of superior quality and nickel plated to facilitate its opening. The door panel must have as arrangement to provide a pad lock. FINISHING: The frame & the door panel should be given anti-rust, anti-grease and phosphate treatment with 3 in 1 paste and then spray painted with two coats of paint of superior quality. The shutter should be earthed properly with the existing earth with No.8SWG wire after erasing the paint from the body of the Shutter. The rate includes cost of all labor and material reqd. to complete the job to the satisfaction of the Engineer-in-charge.
Proposed Interlocking of LC 155 between Bolda - Sirli Stations, LC 33 between Adilabad - Pimpalkhuti Stations and LC 74 between Dinagaon - Jalna Stations over Nanded Division
Fabrication, supply and erection o f conventional Earth to Signalling/Telecom equipments -Excavation o f earth and providing earth pipe of size 50mm dia. 3.5mm thick 2.0 m. long G.I. pipe of heavy quality with masonry tub constructed 18 around at earth locations as specified by site Engineer. Alternate layers of 30kgs-charcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carried out as per drawing No. SK 10/10. The earth pipe to be connected to the function with cable as supplied by Railways. The reading should be painted on the masonry tub. The masonry tub of 300 mm x 300 mm x 300mm (along with Kundi) should be covered with cement slab. Inspection by Consignee.