946 results • Best match
As per Tender
Supply,installation, testing & Commisioning of Connection and regulation kit for HVAC fan coil units / hydronic cassette unit in heating/ cooling systems. Complete with: pressure independent control valve with proportional linear actuator (Modulating type ), three-way shut-off valves, integrated by-pass, Venturi device with pressure test ports, shut off valve with strainer and shell insulation made of PPE. NOTE : all given parts should be of one single manufacturer,no different manufacturer assembelled unit is acceptable. Linear or equipotential flow rate adjustment characteristic, which can be set up by actuator depending on the characteristics of the terminal unit. Maximum working pressure 25 bar. Maximum differential pressure with actuator installed: 5 bar. Nominal operation Δp range 25–400 kPa. Working temperature range -10−120°C. Ambient temperature range 0−50°C. Strainer mesh size 800 µm. Dezincification resistant alloy body and adjustment headwork; stainless steel strainer mesh; EPDM diaphragm, obturator and seals. One pair of flexible connection with threaded nut / clamp to be provided between the unit and kit of suitable length.
Internal electrification, external electrification, fire alarm, PA system, fire fighting, CCTV, Lift, ventilation, construction of boring and 1 year operation at Kisan Agrimall, Vikalp Khand, Gomti Nagar, Lucknow
Ventilation Panel for Lower Basement (Make: L&T/Schneider/Crompton/ABB/Siemens/L&K) UPPWD and CPRI Approved Supply, Installation, Testing and Commissioning of Programmable Logic controller as per the below description and the Tender technical specs: S/I/T/C of Universal Cntroller PLC with main componentslike power, processor, input & output cards, an open protocol for interface with the BMS systems. PLC to be complete as per specs installed inside the Main Switchgear MCC panel. The PLC shall have a FULL MODBus / BACnet / Eithernet interface facility with the Central BMS system. Scope to include the Gateway or converter, Communication module, HVAC software in addition to the standard features. Minimum Specifications of a Controller are as follows (but should meet the project needs): a) 10 x analogue inputs for CO or other pollutant sensors. (0-20mA, 0-5V and 0-10V input available). b) 16 x digital inputs for fan run/fault status. c) 1 x emergency alarm (i.e. fire) digital signal inputs. d) MODBUS, BACnet and other protocols for supervisory connection with BMS system. Built-in communication Modbus slave serial link by means of connection on integrated RJ45 port (Modbus master/slave serial link on integrated RJ45 port). e) 3 x analogue outputs available to speed control groups of JetVent Fans, central car park exhaust fan or supply fan. f) 3 x digital outputs to drive speed control relays (for 2 speed fans) or other systems according to pollutant concentration. a) Programmable Logic Controller with HVAC software b) Dedicated PWM programmable output.
COMPREHENSIVE MAINTENANCE OF AC PLANT 1300 TR CAPACITY INCLUDING ROUTINE MAINT OF SCADA SYSTEM AND VARIOUS SUMMER COOLING APPLIANCES UNDER GE (SB) KARWAR
Supply and fix in repairs PLC control panel (for each AHU) Vajrakosh Magazine including PLC suitable for HVAC application including SMPS,switchgears and relays etc completed all as directed by Engr-in charge.
PROVN OF DE-HUMIDIFIERS AT DIFFERENT LOCATIONS AT AFS AMBALA UNDER GE (P) (AF) AMBALA
M&L CBRI certified 16-gauge GI fire damper (motorized, spring return type, combination fire and smoke damper), at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555, the fire dampers shall meet the following under mentioned criteria, complete all as specified & directed. :- (i) Bare fire dampers with 400mm sleeve. (ii) Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. (iii) Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers. (iv) Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
RMO E and M Services at Delhi Vidhan Sabha, Old sectt., Delhi. (SH- Renovation of E and M Work at various offices in Delhi Legislative Assembly).
The units shall have local LEDs at each individual unit to indicate when the units are up for wash/malfunctioning. The system must include coil mounted Ultra Violet Germicidal Irradiation (UVGI) System for providing protection from airborne infection and maintaining Indoor Air Quality in various type of HVAC units with the following features and technical specifications. The system shall comprise of one or more individual lamps with fixtures (Combinations of 863mm & 1556mm only), reflector(fabricated in Aluminium Alloy with minimum 80% reflectance). The lamps shall be Simple Connection with 4 pin harness. Lamp & Ballast should be from same OEM Manufacturer. The lamp life shall be rated no less than 9000 hours with a derating of less than 15% after 8000 hours. The lamp shall be high output type and should not be lower than 800 mA. Ballast shall not contain any Polychlorinated Biphenyl (PCB).Ballast shall be high frequency electronic type and operate lamps at a frequency above 42 kHz to avoid interference with infrared devices and eliminate visible flicker. Tenderers must submit a Clause-by-Clause Compliance Summary and provide full documentation/ technical literature/ data sheets/ reports to confirm compliance for each clause. All tenderers must submit a design analysis conditional qualification test report to confirm that tests have been conducted based on the above criteria and that the EAC has passed these tests. Vendor to comply all tender specifications. The entire system should be installed under the guidance of OEM/ Channel partner for proper installation & healthy functioning.
SITC of VRF / VRV Type AC and Split-WAC in different locations in IIT Delhi (ACCR FEB 2026)
COOL EARTH HVAC ENGINEERS PRIVATE LIMITED (BID ID -3397248)