ADDN/ALTN TO BLDG NO P-06 (PARA-35) AT HQ NORTHERN COMMAND UNDER GE (UTILITIES) UDHAMPUR
Factory made acoustic modular metal false ceiling of powder coated panels. Make shall comprise of perforated and nonperforated metal panels made through CNC laser Cutting, bending & punching. Panel shall be of 0.6mm CRCA sheet of approved powder coating finish. Panels shall be designed to achieve shape and design as per the design consultant with the combination of acrylic panels with lights, designed to enhance visual feel, with provision for easy installation and maintenance, integrated lighting and scope for integration of building services like HVAC and fire detection/ fighting system. The designer metal ceiling shall be greenguard gold tested/certified (from UL/Intertek). Metal modular false ceiling shall have Noise absorption coefficient (NRC) value 0.60 according to IS:8225-1987, ISO: 354-1985 and ASTM 423-90. The metal ceiling shall sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations or better. The test shall be carried out by authorized government agency. Structure shall be made from heavy duty powder coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm).
Construction and Campus Development for College of Homeopathic 100 Students with 50 bedded Hospital and Allied services such as Hospital, Staff Quarter etc. at Pimpalgaon Khurd Tal. Kagal Dist Kolhapur (Civil and Electrical)
Providing and fixing of Super Hepha filter in machine so we can provide filtered clean air inside the operaton theater with remove at least 99.97% of airborne particles 0.3 micrometers (μm) in diameter. The filter's minimal resistance to airflow, or pressure drop, is usually specified around 300 pascals (0.044 psi) at its nominal flow rate. Filtration Efficiency: ≥ 99.97% for particles ≥ 0.3 μm Particle Removal: Capable of capturing microscopic airborne contaminants including dust, bacteria, and other particulates. Airflow Resistance: Minimal pressure drop, typically around 300 Pascals (0.044 psi) at the nominal airflow rate, ensuring efficient air circulation without overburdening the HVAC system. Filter Size: [Specify dimensions, e.g., 610 mm x 610 mm x 292 mm Frame Material: Aluminum or galvanized steel frame for corrosion resistance Seal: Gasket-sealed perimeter to prevent air bypass Standard Compliance: Designed and tested as per relevant IS/IEC standards for HEPA filters Pressure Drop: Approximately 300 Pa (0.044 psi) at nominal airflow
CONSTRUCTION OF COLLEGE OF FOOD TECHNOLOGY, At YAVATMAL, Under Dr. Panjabrao Deshmukh Krishi Vidyapeeth, Akola.
Sub Work - 4 : HVAC System:- Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/ digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete.
PROPOSED CONSTRUCTION OF OLYMPIC ATHLETE KHASHABA JADHAV WRESTLING HALL AT GOLESHWAR , KARAD TAL- KARAD DIST.SATARA
Supply / Installation / Testing / commissioning of Actuator With It's Cabling and Allow for variable positioning, providing continuous control between fully open and fully closed positions. Modulating actuator type with 0-10V control signal, Operating Voltage: 24V AC, Temperature Range: -10°C to 50°C (14°F to 122°F), IP54 Environmental Rating, UL listed, CE certified with ensure Integration Control compatibility with your HVAC control system or Building Management System (BMS).
SUB-HEAD- Civil Work including Electrical Work, Sanitary and Plumbing, Water Supply, Sewage and other Allied Works etc.
1 No. 630A 4P MCCB,36KA,PRMB with On/Off/Trip Indicator For HVAC
REPAIR REPLACEMENT IMPROVEMENT OF AC PLANTS COMPRESSOR SENSORS COOLING TOWER HOT COLD WATER PIPE LINE INSULATIONS AND REPLACEMENT OF DEFECTIVE ACCESSORIES OF CHILLER CONDENSER UNIT, AHU HEATER AND OTHER ALLIED WORKS OF AC PLANTS OF TUNIR AND COMMON
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp complete all as specified and directed by Engr-in-Charge.