Loading…
Loading…
946 results • Best match
Development of Vyasanagar Stadium, Jajpur as per Letter No- 18763 Dt. 30.07.2025 of Sports and YS Deptt Buildings.
E.I. WORK Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/ Anchor/ Polycab/ HAVELLS/ RR KABLE/ KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/ BEC/ Precision/ Norpak/ Anchor/ Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/ legrand( Myrius) / Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. Group A
REPAIRREPLACEMENT AND IMPROVEMENT OF AC PLANTS COMPRESSOR SENSORS COOLING TOWER HOT COLD WATER PIPE LINE INSULATIONS AND REPLACEMENT OF DEFECTIVE ACCESSORIES OF CHILLER CONDENSER UNIT AHU HEATER AND OTHER ALLIED WORKS OF AC PLANTS OF NAD AREA AT
Supply and fixing of connector in HVAC panel 6 Amp to 35 Amp complete all as specified and directed by Engr-in-Charge.
SPECIAL REPAIR/REPLACEMENT OF BER CENTRAL AC PLANT OF AVIONICS LAB AND SPECIAL REPAIR / REPLACEMENT OF BER CHILLER PLANT AT P-77 (ATEC BLDG) IN TECH AREA AT AF STN GWALIOR
Material & Labour for CBRI certified 16-gauge GI fire damper ( Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.) , at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated cross overs (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directed by the engineer-in-charge. The fire dampers shall meet the following criteriaon:- [i] Bare fire dampers with 400 mm sleeve [ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [iii] Interconnection wire for the fire detection & alarm system with the LCD fire damper controller. [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
Construction work of Sub District Hospital Bijaynagar Distt. Beawar (H.V.A.C. Work)
HVAC PANELS
E.I. (Additional Work) to Library Building of PMEC, Sitalapali at Berhampur, Ganjam.
HVAC WORK(SPLIT TYPE)-AIR CONDITIONER SPLIT SITC of 2.0 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi)
Repair and renovation works of electrical installation along with SITC of distribution LT Panel, Air conditioning, Compound Lighting, Glow Sign Board, LPS System etc at New Integrated Govt. School, Simlapal, Bankura.
Supply & Installation of Extra Add-on items- HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle,screw, insulation tape, fastner etc for above AC machine as per direction of EIC. [NS]