946 results • Best match
Interior partition and other civil works of 2nd floor of RVGH building at IIT Madras to accommodate CCW office
RECEPTION CEILING OPTION 2 - STRETCH CEILING Providing and installing PVC stretch ceiling system for the reception area, suitable for Grade-A office spaces , comprising fire-retardant PVC membrane (minimum 0.18 mm thick) with approved matte/satin/gloss finish, fixed to concealed aluminium / PVC perimeter track system, complete with heat-stretch installation to achieve a smooth, level, wrinkle-free surface. The system shall comply with applicable Indian standards and local fire safety norms (minimum Class B-s1, d0 or equivalent), be moisture-, humidity- and mold-resistant, and suitable for air-conditioned office environments. Provision shall include reinforced cut-outs for lighting fixtures, HVAC diffusers, sprinklers and detectors as required. Rate to include all materials, accessories, fixings, labour, tools, testing, and a minimum 10-year manufacturer warranty, complete in all respects.
CO Development of temporary structure at DGRE SASE Haliport at Manali
Construction of Pre-Fabricated cabin size (12.00x5.00x5.00)mtr roof hut shape as per dreawing. Specifications:-a) outer wall 50mm thick wall puf insulated panel.B) Roof panel (30/70)mm thick puf panelc) Door and window (As per drawing) upvc.D) PPGI Flashings (U-Channel & corners). e) Hardware & Accessories.f) Erection of wall and roof panel.g) Tile flooringh)PVC ceilingincluding all civil work required i.e Foundation, ooting, plinth beam etc, office, toilets,Electrical work ,HVAC,Fire ighting,plumbing & sanitation,earthing,over head tank 5,000 ltr, septic tank etc as all required work completed including carriage of materials with-in all leads and lifts and other incidental and as per entire satisfaction and direction of Engineer-in-Charge. The rate is including Octroi, Royality, Malkana, Toll-Tax or any other imposed by the Government but excluding GST.
Construction of Way Side Amenity Centre WAC at Nimapada in Puri District
SS. WALL HOOD DIMENSION : 90X36X18 Specification : Construction in 20swg 202 grade s.s. sheet Channels for fixing of filters grease drain box s.s. baffle or cyclonic filters high density puff insulation bulk head lights cutouts on top for duct openings as per HVAC consultant
Construction of 200 Bedded Civil Hospital at Sec 9 in Distt. Fatehabad (Pdg. 11 KV Substation, DG Set and Street/Security Lights Only).RECALL
Supply, installation, testing and commissioning of Indoor cubical type main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1and2 with Aluminium bus bar 4000 A. The Panel should be extendable type TTA of ABB (R2k), LandT (Ti), Schneider (Blokset), Siemens (Siepan), The Panel shall have arrangement of connection with cables and to be installed on new suitable foundations with proper provision of incoming and outgoing LT Cables i/c providing following switch gears :-The switchboard shall be factory manufactured Panel shall have top and bottom Entry/Out going type. including Supply, Installation, testing and commissioning of Inert type Novec-1230/FM200 or equivalent Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification and as per direction of Engineer in Charge. Every Cable alley compartment of Panel shall have wired or wireless overheating sensors for cable with alarm system Approved Makes- ACB = LandT (Omega), Schneider(Masterpact NW), Siemens(3WJ), ABB(E Max2). Approved Makes- MCCB = LandT, Schneider, Siemens, ABB. Incomer (From Transformer-1) `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. ` METERING and INDICATION (a) 3 Nos.- RYB PHASE INDICATING LIGHT, 230V AC with each Incomer (b ) 3 Nos.-ON/OFF/TRIP INDICATING LIGHT, 230V AC with each Incomer (c) 3 Nos. CT FOR METERING, 3200/5A , CL-1.0, 15VA (d) 1 Nos. DIGITAL Multifunction Meter (IV,KW,KWH,KVA,PF,HZ Maximum Demand with LCD Display), 96mm square flush pattern with RS485 with each Incomer (e) CONTROL MCB, 2A SP, 10KA `Bus Bar Aluminium Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc. as per Type Tested design of the Approved OEM` OUTGOINGS: `2 Nos. 1250A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. (For HVAC plant and spare) ` `1 Nos. 1000A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter. (For DG-1) ` 2 Nos. 800A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. (For APFC) `3 Nos. 250A FP MCCB Ics= 50kA thermal magnetic type with variable overload MCCB and Fixed Short Circuit protection and EROM (Xray, Medical equipment, CT scan, MRI, Spare) ` `2 Nos. 150A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit Protection and EROM (MGPS, OT) ` `5 Nos. 100A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit and EROM (Mortuary, Ancilinator, Tubwell, Sewage pump, ventilation panel) ` Bus Coupler `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. ` Incomer (From Transformer-2) `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. ` METERING and INDICATION (a) 3 Nos.- RYB PHASE INDICATING LIGHT, 230V AC with each Incomer (b ) 3 Nos.-ON/OFF/TRIP INDICATING LIGHT, 230V AC with each Incomer (c) 3 Nos. CT FOR METERING, 3200/5A , CL-1.0, 15VA (d) 1 Nos. DIGITAL Multifunction Meter (IV,KW,KWH,KVA,PF,HZ Maximum Demand with LCD Display), 96mm square flush pattern with RS485 with each Incomer (e) CONTROL MCB, 2A SP, 10KA OUTGOINGS: `2 Nos. 1250A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For Power load panel, HVAC AHU panel) ` `1 Nos. 1000A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For DG-2) ` 1 Nos. 800A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For APFC Tr-2) `6 Nos. 150A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit and EROM (MGPS alternate, OT alternate, CSSD, Laundary, Fire fighting, spare) WIRING and ACCESSORIES` Power and Control Wiring includinjg interlocking will be provided as per site requirement with (ISI 1100V) FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc. (Rates are of GST excluded)
Civil Renovation work and kitchen ventilation work in the Kailash Hostel, Karakoram Hostel, Vindhyachal Hostel, Jwalamukhi Hostel and Kumaon Hostel at IIT Delhi
Air Supply Grill: Supplying, Fixing, installation, testing and commissioning of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers in confirmation to SMACNA/IS and as per specifications of HVAC complete etc. as required.
Construction of 200 Bedded Civil Hospital at Sec 9 in Distt. Fatehabad (Pdg. 11 KV Substation, DG Set and Street/Security Lights Only).RECALL
Supply, installation, testing and commissioning of Indoor cubical type main LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel as per IEC 61439-1and2 with Aluminium bus bar 4000 A. The Panel should be extendable type TTA of ABB (R2k), LandT (Ti), Schneider (Blokset), Siemens (Siepan), The Panel shall have arrangement of connection with cables and to be installed on new suitable foundations with proper provision of incoming and outgoing LT Cables i/c providing following switch gears :-The switchboard shall be factory manufactured Panel shall have top and bottom Entry/Out going type. including Supply, Installation, testing and commissioning of Inert type Novec-1230/FM200 or equivalent Fire Detection Tube based Gas suppression system for electrical panel. It includes all the require accessories/equipments to complete the panel protection, as per detail specification and as per direction of Engineer in Charge. Every Cable alley compartment of Panel shall have wired or wireless overheating sensors for cable with alarm system Approved Makes- ACB = LandT (Omega), Schneider(Masterpact NW), Siemens(3WJ), ABB(E Max2). Approved Makes- MCCB = LandT, Schneider, Siemens, ABB. Incomer (From Transformer-1) `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. ` METERING and INDICATION (a) 3 Nos.- RYB PHASE INDICATING LIGHT, 230V AC with each Incomer (b ) 3 Nos.-ON/OFF/TRIP INDICATING LIGHT, 230V AC with each Incomer (c) 3 Nos. CT FOR METERING, 3200/5A , CL-1.0, 15VA (d) 1 Nos. DIGITAL Multifunction Meter (IV,KW,KWH,KVA,PF,HZ Maximum Demand with LCD Display), 96mm square flush pattern with RS485 with each Incomer (e) CONTROL MCB, 2A SP, 10KA `Bus Bar Aluminium Bus Bar,Load wise Sub Feeder Bus Bar Colour Coated Heat Shrink Bus Bar sleave Nut-Bolt,Washer ,Hardware etc. as per Type Tested design of the Approved OEM` OUTGOINGS: `2 Nos. 1250A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. (For HVAC plant and spare) ` `1 Nos. 1000A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter. (For DG-1) ` 2 Nos. 800A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. (For APFC) `3 Nos. 250A FP MCCB Ics= 50kA thermal magnetic type with variable overload MCCB and Fixed Short Circuit protection and EROM (Xray, Medical equipment, CT scan, MRI, Spare) ` `2 Nos. 150A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit Protection and EROM (MGPS, OT) ` `5 Nos. 100A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit and EROM (Mortuary, Ancilinator, Tubwell, Sewage pump, ventilation panel) ` Bus Coupler `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. ` Incomer (From Transformer-2) `1 No. 3200A FP EDO ACB Icw=55kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. ` METERING and INDICATION (a) 3 Nos.- RYB PHASE INDICATING LIGHT, 230V AC with each Incomer (b ) 3 Nos.-ON/OFF/TRIP INDICATING LIGHT, 230V AC with each Incomer (c) 3 Nos. CT FOR METERING, 3200/5A , CL-1.0, 15VA (d) 1 Nos. DIGITAL Multifunction Meter (IV,KW,KWH,KVA,PF,HZ Maximum Demand with LCD Display), 96mm square flush pattern with RS485 with each Incomer (e) CONTROL MCB, 2A SP, 10KA OUTGOINGS: `2 Nos. 1250A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSING protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For Power load panel, HVAC AHU panel) ` `1 Nos. 1000A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For DG-2) ` 1 Nos. 800A FP EDO ACB Icw=50kA ,Microprcoessor based release with LSIG protection along with variable current setting for L,S,I,G and variable time delay setting. Release with LCD Display for Current Parameter, Individual fault Indication. Copper Terminal adaptors on both side of ACB is reqd. (For APFC Tr-2) `6 Nos. 150A FP MCCB Ics= 50kA thermal magnetic type with variable overload and Fixed Short Circuit and EROM (MGPS alternate, OT alternate, CSSD, Laundary, Fire fighting, spare) WIRING and ACCESSORIES` Power and Control Wiring includinjg interlocking will be provided as per site requirement with (ISI 1100V) FRLS PVC Single Core Copper Wire,Copper Lugs, PVC Sleeve, Ferruels Numbers, Hardware and Labour etc. (Rates are of GST excluded)