Loading…
Loading…
946 results • Best match
Interior Fitout and allied works for Work near home facility at ASAP building Kalamassery Ernakulam
Heating, Ventilation and Air Conditioning (HVAC) Works
Renovation of toilets and change rooms in various plants and office buildings in Zirconium complex, Pazhayakayal, Tuticorin - 628152
Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, antisyphonege, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil / waste pipe as per IS:13592 and IS:14735 Grade-B laid in floor & on Exposed faces of wall of Supreme make ii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved make iii) Providing and fixing uPVC cowl at the top of soil, waste water, rain water & vent pipe line. iv) Laying the pipe below floor / ground to proper slope and gradient for making connections of soil / waste water pipe line with inspection chamber or Manhole, including the cost of cement mortar, cement concrete, water proofing compound etc. v) Jointing the pipe with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Giving water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at consealed locations. vi) Necessary cutting to the required length including short pieces, fittings with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, cleaning pipe, single & double Y, vent cowl, gaskets, offsets, grattings, Tank / WC connectors etc.
Construction of temporary site office for CPM, Design, Track and Architect/EndM with resting facilities near IFFCO Chowk, Sector-29, Gurugram for implementation of Delhi-Gurugram-Bawal Namo Bharat Corridor.
HVAC (E)
Request for Proposal (“RFP”) issued by NHIT Southern Projects Private Limited (NSPPL) for Engagement of Agency/Firm for Supply, Installation, Testing and Commissioning of Pre-Engineered ATMS Buildings Works for the projects under NSPPL.
Supply, Installation, testing and commissioning of IP 42 rated HVAC PANEL FOR HELIPORT Having, Incomer 400 Amp 35 KA FP MCCB (01 No), Out Going: 160 Amp FP 16KA MCB (01Nos), 125 Amp FP 16KA MCB (02Nos), ALSO REFER SLD ALONG WITH THIS. ALL SHOULD BE AS PER SLD & REQUIREMENT.
PROVN OF AUDITORIUM COMPLEX AT AUNDH UNDER GE (MH AND RH), KHADKI.
FIRE & SMOKE DAMPER M & L for CBRI certified 16-gauge GI fire damper, at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermistor, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossovers (shafts, walls, etc.) along with control panel (located in such a way that the reset may easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire / smoke in the respective zone and tested as per UL-555 complete all as specified and directed by the engineer-in-charge. The fire dampers shall meet the following criteriaon: [i] Bare fire dampers with 400 mm sleeve [ii] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position [iii] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers [iv] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
PROVN OF CENTRALISED AC AND ACOUSTIC PANELING FOR AUDITORIUM AT SUTRAGARH MIL STN
Material and labour for hydronic balancing of HVAC Equipment water flow by NEBB Certified agency. Contractor has to submit the NEBB certificate before starting of work complete all as specified and as directed.