Loading…
Loading…
946 results • Best match
REPAIR MAINT OF CENTRAL AC PLANTS PACKAGE AC PLANTS INSTALLED AT R AND DE DIGHI AND VRDE AHMEDNAGAR 06
Supply and Fix in repairs of factory fabricated galvanized steel sheet metal (G.S.S.) round / rectangular ducting of following sheet thickness having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports, etc. as per approved drawings and conforming to the latest edition of IS 655: 2006 & HVAC Duct Construction Standards - Metal and Flexible of SMACNA along with required scaffolding work to install the ducts at sitecomplete all as specified and directed for following :- (a) 18 G
SPECIAL REPAIRS FOR REPLACEMENT OF 2 X 35 TR AC PLANT IN AUDITORIUM AT NSTL UNDER AGE I RND NSTL, VISAKHAPATNAM
MAIN LT PANEL (HVAC) (a) Supplying, installation, testing & commissioning of cubical type wall / floor mounted distribution panel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates including cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type FP aluminium alloy bus bars of high conductivity, SMC bus bar supports with short circuit withstand capacity of 35kA for 1 sec with entire panel shall have a common aluminium earth bus of size 32 x 6mm at the rear with 02 Nos earth stud, solid
Construction of 220/132KV, 2X160 MVA AIS Substation at Morigaon along with associated transmission lines, (Package P-II-E)
HVAC DB
Construction of VKNRL Hospital Extension building at NRL Township and external site development works
0.000 AIR HANDLING UNITS FOR MAJOR OT (FULLY AHRI CERTIFIED) - 3 STAGE FILTRATION AND INDOOR TYPE Supply, Installation, Testing and commissioning of factory built floor mounted double skin type Air Handling Unit with Mixing Box, sectionalized, made of extruded Al section frame structure with thermal break profile of 42±2mm thick panels consisting of GI casing of thickness 0.6mm outside layer and 0.6mm aluminium sheet inside layer with polyurethane foam (PUF) insulation of density 40±2Kg/cum factory injected between them by injection moulding machine complete with backward curved blower section, 6 row deep DX cooling coil section , (SS-304 end cover plate) with aluminium finned copper tubes ( tube thickness not less than 0.41 mm & 11-13 Fins / Inch). TSP 120 mm minimum and to be verified by contractor. THERMOSTAT automatic temperature control. All units shall be BMS compitable . The AHU shall be completed with 18G stainless steel- SS304 drain pan with19 mm thick closed cell class- O nitrile insulation,fire retardent canvas connection and necessary vibration isolation arrangement etc. Ultra Violet Germicidal Irradiations ( UVGI) System for maintaining indoor Air Quality in TFA/AHU unit. The lamp shall have 10000 hrs life, ballasts shall be electronic type. The lamp should be designed to achive kill rate of not less than 90% per pass. The components of the system must be in strict conformity with the specifications. The prices to include all inter connected wiring between the UVGI Lamps. The AHU shall be completed with 18G stainless steel- SS304 drain pan with19 mm thck clsed cell class- O nitrile insulation,fire retardent canvas connection and necessary vibration isolation arrangement etc. Ultra Violet Germicidal Irradiations ( UVGI) System for maintaining indoor Air Quality in TFA/AHU unit. The lamp shall have 10000 hrs life, ballasts shall be electronic type. The lamp should be designed to achive kill rate of not less than 90% per pass. The components of the system must be in strict conformity with the specifications. The prices to include all inter connected wiring between the UVGI Lamps. The complete AHU shall confirm to specification & face velocity across cooling coil shall be limited to 400 FPM maximum and fan outlet velocity not more than 1870 FPM. The complete AHU shall confirm to specification & face velocity across cooling coil shall be limited to 400 FPM maximum and fan oullet velocity not more than 1870 FPM.AHU DX 6 or 8 ROW DEEP coils as per OEM selection sheet ( To be approved by consultant) . Equal divisions shall be made in cross sectional area of the coil TSP respectively or as per manufacturer standard. The unit shall be suitable for outdoor installation and the static pressure will be calcualted by HVAC contractor on basis of final duct layout. The motor shall be TEFC drive motor (IE3 ) suitable for 415±10% volts, 50 Hz, 3 phase, A.C. supply.De-humidification: Strip Heater with auto cut off and on and integrated with RH sensor and thermostat Filter :Pre filter 90% efficiency to 10 microne and fine filter 96.99 % efficiency to 3 microne and HEPA 99.97% down to 0.3 Micron 2800 CFM, 8.5 TR, 2x 3.5kW Strip Heater, 120mm WC TSP, Floor Mounted for OT-1 NIL328 NOS Excess(+) Full Conversion INR
Construction of Model Primary Health Center PHC in Belgaria Township at Dhanbad (2nd Call).
Supply, laying, testing and commissioning of power and control cabling as per specification given in the tender. A) Power cabling (XLPE insulated Aluminum / Copper conductor as given below armoured / unarmoured cables of 1.1 KV Grade) including cable end termination with brass compression glands & lugs etc. as per specification. Note:- Power cable with earthing shall be made available near indoor / outdoor units. Only termination into HVAC equipment's (Indoor & Outdoor) shall be done by HVAC Contractor. 4C x 10 Sq. mm Copper Conductor (Armoured) For AHU/Vent
Construction of Proposed TNPCBs R and D Building for Tamil Nadu Pollution Control Board adjacent to existing TNPCB Corporate office at Guindy in Chennai city
HVAC Works VARIABLE REFRIGERANT SYSTEM(VRF SYSTEM) VRF Outdoor Unit Supply, Lifting, Installation, Testing & Commisioning of VRF unit with inverter scroll compressor connectable to multiple indoor units. a) 20.0 HP