Loading…
Loading…
947 results • Best match
UPGRADATION OF EXISTING 100 BEDDED TLH TO 150 BEDDED TLH AT KUDLUGI, VIJAYANAGAR DISTRICT
Supply, Installation, Testing & Commissioning of Variable frequency drives, metering, all accessories, controls, harmonic filters for HVAC equipment.
Construction of Seafarers Club in custom bond Area at V.O.Chidambaranar Port
HVAC Providing and fixing of Air conditioner including design with detailed analysis on heat load and other parameters. The Air conditioners shall be aesthetically designed with good energy efficiency. The air conditioners condenser and evaporator shall be of copper and the air conditioners shall be energy efficient (inverter). All the basic features including remote settings shall be made available. The air conditioners shall be supplied and installed with all necessary accessories (stand, connecting tube, extendable copper tubes, interconnecting wiring arrangement, drain tubes, insulation materials, etc). The cost including for all the required materials for complete electrical works, duct/drainage arrangements, fitting charges, labour, transport etc. The AC of Toshiba Cassette AC sh
Construction of District Ayush Office at Barbar shah Srinagar.
(B) HVAC Split Acs
Development of Eco Park (Package-IV) at Ooty in Nilgiris district, Tamilnadu.
Supplying, installation, testing, and commissioning of wall-mounted LT distribution panel suitable for 3-phase, 433 V, 50 Hz AC supply, fabricated from CRCA sheet steel of minimum 2 mm thickness, powder-coated with IP42 protection, comprising one no. 4-pole MCCB of 40 A, 25 kA breaking capacity as incomer, tinned copper busbar rated for 100 A, 6–8 nos. outgoing MCBs (SP/TP) rated 10–32 A for lighting, kitchen, HVAC, and signage circuits, one no. Class II surge protection device (SPD) rated 20–40 kA, phase indication lamps (R/Y/B), trip indicator, bottom gland plate for cable entry, and provision for digital kWh/kVAh meter with CTs (optional). Panel shall be wall-mounted at 1.5 m height from FFL with adequate front clearance, internally wired with FRLS copper cable, and terminated using compression lugs and heat shrink sleeves. Complete with earthing arrangement using 2 nos. 16 sq.mm copper leads and circuit labeling as per site layout. All works shall be executed as per IS 8623, IS 13947, and CPWD electrical specifications
Modernization of Jorhat Science Centre and Planetarium
SITC of HVAC works for VRV/VRF system including indoor/outdoor units, piping, electrical,power distribution/wiring,electrical panel,treated fresh air system etc.
Civil and MEP works
HVAC Shaft - Supply and installation of Fire stop mortar system with minimum 2 hours fire rating in services passing through fire rated walls and floors made of concrete, masonry, metal, gypsum partition when tested in accordance with UL1479 standards, for horizontal openings in floors or slabs after passing service lines like Metal Pipes or Ducts. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999- 11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-historymethod and VERTEQII for seismic zone 4. Acrylic fire stop sealant with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the peripher of ducts & chiller pipes without insulation. Fire intumescent firestop sealant with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes with insulation. The products shall be age tested as per Dafstb and DIBT standards. The products shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The products shall be UL listed & classified and shall bear the UL approval logo on the packing..Engineering Judgements (EJs) should be used for situations where a tested system is not available. The application to be executed by manufacturer approved firestop contractor, (Ratio of Mortar to sealant can be assumed as 70% & 5% Respectively). Assumed 25% Penetrants Occupancy.