Construction of New Section Office building for Udala (R and B) Section-I under Mayurbhanj (R and B) Division at Udala Town for the year 2025-26
ELECTRICAL INSTALLATION Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. NB:All the electrical,Fire fighting,HVAC,ELV drawings, Technical Data Sheets & make will be approved by SE R& B Electrical circle & CE Building ,Odisha ,Bhubaneswar prior to execution of the work. GROUP-A
Construction of Cancer Care Centre (2nd Floor to 5th Floor) at VIMSAR, Burla.
Supply, Installing, Testing and Commissioning of VANE AXIAL FANS as per specifications stated below. Fan shall be direct driven Vane axial fan AMCA Certified (For Air and Sound Performance as well as FEG). The fan shall be equipped with mounting bracket, inlet guard (If required) & spring isolators for the installation of the fans. Motors shall be VFD Compatible suitable for 415+10% volts, 50 cycles, 3 phase AC supply. Fan static pressure shall be as indicated but actual fan static pressure to be checked by HVAC / MEP Vendor. Supply Fans shall be activated from fire signal from fire alarm system. Fan shall be with fire proof flexible connection at outlet. Motors shall be of minimum IE2 efficiency. Fan total efficiency should not be less than 72% and FEG should not be less than 85, noise level should not be more than 84 dB(A) @ 3m distance when measured in hemispherical reverberant room conditions. Sound attenutors of appropriate length shall be included in the cost to achieve the desired result. Make - Greenheck / Systemair
Construction of Block Level Stadium with Indoor Hall in Dharmasala Block under Jajpur District.
Maintenance (Civil, Electrical and PH items) - A) First year- (A) Routine maintenance of all civil structure and sports facilities constructed including labour & materials for all Civil works for 5 years including all types of minor repair of flooring, plastering ,door windows ,celling, coloring the entire structure both internal and external etc as per standard maintenance procedure , codal provision and specifications, special conditions, additional conditions etc. and as per agreement provisions to complete repair work as per direction of Engineer-in-charge. (B) Routine inspection and preventive maintenance of main LT panels, sub-distribution boards, MCC panels, and control panels, checking of internal wiring circuits for lighting, power, and specialized medical equipment, regular maintenance of internal lighting (general and emergency), corridor and ward lights, and external compound lighting, operation and maintenance of DG sets, automatic changeover panels, and UPS systems for critical medical areas , periodic testing of earthing pits and recording resistance values, replacement of damaged switches, fuses, indicators, damaged wires, damaged light, driver as required. Cleaning of filters, cooling coils, drain trays, checking refrigerant levels, compressor condition, and electrical controls, cleaning of air ducts, grills, and diffusers to maintain hygiene standards and air quality, operation and maintenance of exhaust fans, fresh air units, and ventilation systems in toilets, laboratories, and isolation wards, supply and replacement of consumables like filters, belts, bearings, lubricants, etc., as per schedule. Deployment of qualified and licensed electricians and trained HVAC technicians during working hours as and when required for maintenance or replacement of any equipment. Maintenance of all the internal and external PH services i.e. internal sanitary work, external service lines, water supply work, drainage system, rainwater harvesting system, bathroom. Urinal toilet etc. complete for the building including all pipes, fittings, fixtures testing etc. complete as approved by the department and as per the direction of Engineer in Charge.
Construction of Block Level Stadium with Indoor Hall in Korei Block under Jajpur District.
Maintenance (Civil, Electrical and PH items) - A) First year- (A) Routine maintenance of all civil structure and sports facilities constructed including labour & materials for all Civil works for 5 years including all types of minor repair of flooring, plastering ,door windows ,celling, coloring the entire structure both internal and external etc as per standard maintenance procedure , codal provision and specifications, special conditions, additional conditions etc. and as per agreement provisions to complete repair work as per direction of Engineer-in-charge. (B) Routine inspection and preventive maintenance of main LT panels, sub-distribution boards, MCC panels, and control panels, checking of internal wiring circuits for lighting, power, and specialized medical equipment, regular maintenance of internal lighting (general and emergency), corridor and ward lights, and external compound lighting, operation and maintenance of DG sets, automatic changeover panels, and UPS systems for critical medical areas , periodic testing of earthing pits and recording resistance values, replacement of damaged switches, fuses, indicators, damaged wires, damaged light, driver as required. Cleaning of filters, cooling coils, drain trays, checking refrigerant levels, compressor condition, and electrical controls, cleaning of air ducts, grills, and diffusers to maintain hygiene standards and air quality, operation and maintenance of exhaust fans, fresh air units, and ventilation systems in toilets, laboratories, and isolation wards, supply and replacement of consumables like filters, belts, bearings, lubricants, etc., as per schedule. Deployment of qualified and licensed electricians and trained HVAC technicians during working hours as and when required for maintenance or replacement of any equipment. Maintenance of all the internal and external PH services i.e. internal sanitary work, external service lines, water supply work, drainage system, rainwater harvesting system, bathroom. Urinal toilet etc. complete for the building including all pipes, fittings, fixtures testing etc. complete as approved by the department and as per the direction of Engineer in Charge.
Construction of Multi Purpose centre at Kakkanji Nagar Vyasarpadi Chennai
ELECTRICAL WORKS & HVAC Works
Electrification of Vaikalpik Bhawan at Secretariat Campus Dehradun.
HVAC Outdoor Unit Supply, Installation, Testing & Commissioning of modular type Variable Refrigerant Flow / Variable Refrigerant Volume air cooled outdoor units suitable for cooling and heating, having all hermitically sealed inverter type scroll compressor(s), minimum two compressor for above 14 HP modules, microprocessor based controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required, The unit shall deliver the rated capacity at AHRI conditions and work even at 500C ambient temperature without tripping. The unit shall be suitable to wok on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Make- Daikin/Mitsubishi/Toshiba)