Loading…
Loading…
949 results • Best match
Construction of PHC building at Kalapat under Harichandanpur block and at Kalanda under Banspal block in the district of Keonjhar Odisha
In commer-1-01 number of 160A 4P Icu=100%Ics,0, LSIG MCCB with micro processor based release Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(HVAC & MEDICAL EQUIPEMENT)(200 KVA TRANSFORMER)
Construction of PHC building at Chimila under Champua block and at Jyotipur under Champua block in the district of Keonjhar Odisha
In commer-1-01 number of 160A 4P Icu=100%Ics,0, LSIG MCCB with micro processor based release Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(HVAC & MEDICAL EQUIPEMENT)(200 KVA TRANSFORMER)
Construction work of New Building of R.S. P. College, Jharia under Binod Bihari Mahato Koyalanchal University, Dhanbad
HVAC WORKS
Construction of New Administrative Building For The Office of commissioner of Social Justice at Pune.
SITC of HVAC Panel,The panel shall be comprising of following & IEC 61439, Panel should be fully compartmentallised, wall mounted with M.S. Channel dully painted, fabricated of 14/16swg CRCA sheets completely derusted, chemically treated and powder coated with approved shade, ON - Off Indicating LED lamp, locking arrangements, withdual source intelligent flush mounted panel meter three phase four wire (IPM) 415V CT/ PT site programmable class I flush mounted (96 x 96mm) meter with voltage, current, frequency, power factor , ON hrs, kWh and LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden as per SLD having following items:- Main I/O 1000 Amp ACB. 650V, rated at 50º C without deration, 12kV Impulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display 1000 A Bus bar chamber TPN & E with aluminium bars Outgoing-63A TP MCB-4 Nos, 32A TP MCB -36Nos (RA Sheet Attached)
Revamping of Trunk Infrastructure Facilities at MEPZ Special Economic Zone, Tambaram, Chennai
EARTHING GI Earthing for Process Equipment, HVAC equipment, Utility equipment, Electrical DBs body earthing
Construction of Multi Level Car Parking MLCP having G plus 4 floors RCC framed structure including Civil, Public Health Engineering, Electrical and Firefighting works at Anushaktinagar, Mumbai-400094
Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, anti syphonage, HVAC waste pipe and rain water pipe lines consisting following items of work:- i) Providing and fixing uPVC UV-Stabilised Soil/ waste pipe as per IS:13592 and IS:14735 Type-B laid in floor & on Exposed faces of wall of approved make ii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved make iii) Fixing the pipeline Horizontaly with specified slope below the ceiling by Metal clamps with rubber seal and GI hanger rods not less than 5mm dia at specified spacing, including all required hardware. iv) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line. v) Providing and fixing uPVC P/S trap on line as per requirement for soil,waste water pipeline. vi) Laying the pipe below floor / ground to the slope and gradient equal to (or) steeper than 1 in 50, making leak proof connections of soil /waste pipe line from the shaft with inspection chamber / Manhole / Gully trap Chamber including the cost of filling around the holes of inspection chamber / Manhole / Gully trap with cement mortar 1:1 mixed with water proofing compound