Loading…
Loading…
949 results • Best match
Ram Ganga Nagar awasiye yojna ke sec-12 me utsav bhawan ka nirman/vikas karye
Installation of HVAC units, laying of pipes etc. complete (NSR)
Ram Ganga awasiye Yojna ke sec-11 me box village ka nirman karye (Exhibition Hall, Club House, kiosk/Outlet, Swimming pool and development works (Road, Boundary wall, Water Body, Screen wall, Toilet Block, Guard room, Main gate, horticulture, externa
P&F for Rooms Interior as per drawing received from Architect in charge, inluding furniture, HVAC, curtains, rugs, key management system etc. (NSR )
Balance work for Institute of Paramedical and Nursing Sciences at Udalguri District under SDP to be funded by Govt. of Assam.
HVAC Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s) ,minimum two compressors for above 14HP modules, microprocessor based Controller ,top discharge type condensing unit(s), with R410A Refrigerant ,vibration isolators ,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Condition s and work even at 50°C ambient temperature without tripping. The units hall be suitable t owork on 400V+/- 10%,3Phas e,50Hz AC power supply .The unit shall be filled with first charge of the refrigerant and ready for use as required .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 (Approved Makes :Daikin /Toshiba/ General /Mistribushi /Voltas ) Outdoor Units 20 HP
Balance Work for Institute of Paramedical and Nursing Sciences at Tamulpur, Baksa District under SDP to be funded by Govt. of Assam.
HVAC: VRV Out Door units : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s) ,minimum two compressors for above 14HP modules, microprocessor based Controller ,top discharge type condensing unit(s), with R410A Refrigerant ,vibration isolators ,with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Condition s and work even at 50°C ambient temperature without tripping. The units hall be suitable t owork on 400V+/-10%,3Phas e,50Hz AC power supply .The unit shall be filled with first charge of the refrigerant and ready for use as required .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 (Approved Makes :Daikin /Toshiba/ General /Mistribushi /Voltas ) Outdoor Units 20 HP
Construction of Residential Block and Associated Facilities at Advanced Cancer Institute (ACI) Bathinda, Punjab
HVAC WORK
(Part-1) C/O Building Portion, WS SI, Septic Tank, Rain Water Harvesting Tank, Site Development and approach road). (Part-II (Electrical Works) (SITC Electrical Installation, lifts, Addressable Fire Alarm, fire fighting system, MGPS system, Solar P
HVAC : Supplying, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating having 100% ( one hundred percent) hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39°C. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity 40 kWr ISEER 5.4, Capacity > 40 and 70 ISEER 5.5, Capacity > 70 ISEER 5.6 for ECSBC Building) For Cooling and Heating to complete the job including desining and five year on site warranty. The rates are inclusive of carriage of materials within all leads and lifts and all taxes of octroi ,royality, malkana, toll tax, sale tax Gst or other taxes as imposed by the Govt time to time where applicalble . Outdoor Unit PER HP Make :- Daikin/ O General/ Mitsubishi/ Hitachi