Loading…
Loading…
949 results • Best match
Construction of State Emergency Operation Centre SEOC and Allied Civil Works in Guwahati Assam under AIRBMP
Supplying, drilling /cleaning hole and fixing of HILTI Torque Controlled Expansion Anchor HST2 V3, of sizes ranging from M8 to M16 for fixing of HVAC ducts. The Anchor should possess ETA Certificate for use in both Cracked Concrete and non-cracked concrete, approved as per Seismic C1 and C2 Category and have Fire Resistance values for up to 120 mins tested in accordance with EAD 330232-01-0601. The anchor should be pre-assembled with a galvanized bolt as per EN ISO 4042: 1999, a nut of Strength Class 8 (EN ISO 20898-2:2012) and a galvanized washer (EN ISO 4042:1999). It should also possess FM Approval for use in Pipe Hangers. Design of Anchor should be done as per EC2 Part-4 using PROFIS Engineering Software as per actual load data and site conditions as provided by structural consultant and the report to be submitted to the project manager and design engineer for approval. Anchor shall be driven with the help of HS-SC setting tool ,fixed at right embedment depth as per design report and activated using Hilti SIW 6AT-A22 Impact Wrench with adaptive torque Module to ensure adequate torque as per the given diameter mentioned in the ETA.The same must be documented in the form of software generated report and shall be submitted to the peoject manager at the time of inspection. Scanning before drilling to be done with Hilti PS Scanning tool to avoid rebar hits. Safety stud anchor HST2 V3 M10x110
Construction of PHC building at Kalimatii under Joda block and at Malda under Jhumpura block in the district of Keonjhar Odisha
In commer-1-01 number of 160A 4P Icu=100%Ics,0, LSIG MCCB with micro processor based release Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(HVAC & MEDICAL EQUIPEMENT)(200 KVA TRANSFORMER)
Construction of PHC building at kendeiposi under patna block and at Maidankela under sadar block in the district of Keonjhar Odisha
In commer-1-01 number of 160A 4P Icu=100%Ics,0, LSIG MCCB with micro processor based release Electrical locking for normal & DG (make-ABB/Siemens/SCHNEIDER/L&T/Legrand, ISI marked)(HVAC & MEDICAL EQUIPEMENT)(200 KVA TRANSFORMER)
CONSTRUCTION OF PROPOSED COMMAND CONTROL CENTER (CCR - 2) BUILDING AT HARIDWAR, UNDER KUMBH MELA - 2027
ELECTRICAL WORK :- HVAC Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below and complete as per CPWD specification, connections, inter connections etc. as required. (For capacity 40 kWr ISEER 7.4, Capacity > 40 and 70 ISEER 7.5, Capacity > 70 ISEER 7.6 for Super ECSBC Building) For Cooling or Heating or Both (Considering conversion factor IHP= 0.83TR) Outdoor capacity in HP
CONSTRUCTION OF MAHAKAL MAHATIRTHA IN MATIGARA, SILIGURI, DARJEELING.
CONSULTANCY FEES = i) Master planning, Campus Design and Consultancy ii) Mandir Architecture Design, Coordination and Consultancy iii) Landscape Planning & Design iv) Specialised Vaastu Consultancy v) Structural Design, Detailing and Consultancy (Including IIT/Instutional vetting) vi) Interior Planning, Design, Acoustics and Decoration Consultancy vii) Facade Engineering, Design & Consultancy viii) Illumination Design and Consultancy ix) PHE Design (Including Fountain design intent) And Consultancy x) Fire Detection & Fire Fighting Design (Including Provitional and Final NOC) xi) Electrical And ELV Design and Consultancy xii) HVAC Design & Consultancy xiii) Security, Vigilance & Control Design & Consultancy xiv) Environmental Graphics and Signage Design. xv) Mandir sculptures and Mural design intent. xvi) Coordination & approval of shop drawings of Stone Work. xvii) Coordination & approval of shop drawings of Shiv Murti Work with concerned vendor. xviii) Periodic supervisoin (Once site visit Monthly) including all. xix) Energy Survey, Drone Survey, and Soil Investigation Report xx) NOC or liasoning with any other authority for sanctioing the entire project from the concerned authority.
Building Work
40007583 Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars, interconnections ,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. ( Make of switchgear - LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L &T (Equievalant model)/model) /ABB(Equivalant model) ISI marked) or equievalant make with proper model HVAC PANEL with 160A 4P MCCB (36kA)- 1 No as incomer, 63A 4P RCBO (300mA)- 3 Nos, 40A 4P RCBO (300mA)- 3 Nos, 32A 4P RCBO (300mA)- 2 Nos, 32A 2P MCB- 3 Nos as Outgoing and 3nos 160/5A CT, 0-160A Digital Ammeter and 160A aluminium Bus Bars. Ground Floor