Loading…
Loading…
496 results • Best match
Construction of Sump Well cum Pump Room at Hakikat Nagar, Ward No. 12/AC-03(Timarpur). Sub.Head P/F of Energy Efficient Electric Pump Sets with allied works under Civil Line Zone.
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: 3.5 dB/km at 850 nm, 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, uly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR- 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as required. (a) 12 Core Multi Mode Optical Fiber Cable
Provision of 3 phase supply to proposed 2x25 kV TSS at Badnera i.e. (A) Supply & erection of EHV equipments for proposed 3rd phase of TSS-I & II bay at 220 kV Badnera S/Stn under EHV O&M Division, Amravati. (B) Stringing of 3rd phase for existing 220 kV Badnera TSS - I & II line (C)Conversion of existing 2-phase to 3- phase of 132kV Akola-TSS DCDC line along with replacement of existing 132 kV TSS I & II Bay equipment's under jurisdiction of EHV Line Maint. Sub Division - II, Akola & 220 kV S/Stn Akola under EHV (O&M) Division, Akola & 400 kV R.S. Division, Akola respectively, in connection with Up-gradation of Electric Traction System from 1x25 kV to 2x25 kV Traction System in Bhusawal division of Central Railway to meet 3000 MT loading target.
46 46 Fibre optics cable (laying &termination) Kilometre 0.65 7801.00 5070.65
CIVIL WORKS
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit
Entrance Gate and Way side Amenity Centre near Kunduli Square for Integrated Development of Deomali in Koraput District
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax/ Legrand/ Panduit
Supply, installation, testing and commissioning of passenger amenities and other telecom assets at Agasan, Juchandra, Kaman Road, Kharbav Nilje, Palasdhari, Kelavali, Dolavali, Lowjee, Navde Road, Taloje Panchnand and Kalamboli Stations of Mumbai Division.
Optical Fibre Splicing Machine 4.5 Inches and as per technical specification in chapter III of tender document. Inspection by consignee.
Construction of new building with classrooms and Laboratories at Niranjan Govt. Womens College Aska, Ganjam
SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125µm. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit