Visakhapatanam, Andhra PradeshAOC Updated 14 May 2026
Supply of Indoor Type 11 KV and 420V, 2500 KVA Distribution Transformer with RTCC Panel and Local Scada, Erection, Installation, Testing and Commissioning Of Indoor Type 11 KV and 420V, Supply of 4000A LT Panel, Testing and Commissioning of 4000A LT Panel, Supply of 2500A ACB, Retrofit of 2500A LT Panel, Supply of 3X400Sqmm HT 11KV Al Cable, Supply of 3.5X400Sqmm LT 1.1KV Al Cable, Laying, Testing and Commissioning of 3X400Sqmm Al. cable, Testing and Commissioning of 3.5X400Sqmm Al. cable, Providing of Earth pits with required copper and GI flats, Supply of Cable End terminations HT and LT kits and carrying out HT and LT End Terminations including straight through joints, Shifting of 1600KVA, 1000KVA and 750KVA Transformers
Design and Supply of 11 KV, 630A, 25KA, Erection, Testing and Commissioning of 11 KV, 630A, 25KA, Supply of Earthed armoured, aluminium conductor XLPE Power cable, Laying of Earthed armoured, aluminium conductor XLPE Power cable, Supply and making straight through joint with cast resin compound, Supplying and making end termination with brass compression gland and AI.Lugs, Supply of Control Cable PVC insulated, sheathed, unarmoured, flexible copper conductor Cables, Laying and connectorization of Control Cable PVC insulated, sheathed, unarmoured, flexible copper conductor Cables, Supply part for Maintenance Free Earthing System, Service part for Maintenance Free Earthing System, Supply of 50x6 GI strip, Laying of 50X6 GI strip, Removing and dismantling of Existing HT Panels and shifting to store, Supply and placement of 3 mm Thick Rubber Mat. CLASS B, Supply, Fabrication and installation of MS items, Supply and installation Shock hazard charts complete with frame and glass in English and Hindi, Supply and installation First Aid Boxes, Supply and installation of 5 Kg capacity CO2 type fire extinguishers, Supply and installation of Sand buckets with stand Each with at least 3 sand buckets, Supply and placement of Rubber hand gloves 11 kV grade, Supply and installation of Enamelled caution boards, Supply and installation Discharge rod with earthing facility upto 11 kV grade, Supply of Battery Charger with 24V, 25A FC FCBC, Installation, Testing and Commissioning of Battery Charger with 24V, 25A FC - FCBC, Excavation of cable trenches depth upto 1.5 Mtr
Visakhapatanam, Andhra PradeshAOC Updated 14 May 2026
Supply of Indoor Type 11 KV and 420V, 2500 KVA Distribution Transformer with RTCC Panel and Local Scada, Erection, Installation, Testing and Commissioning Of Indoor Type 11 KV and 420V, Supply of 4000A LT Panel, Testing and Commissioning of 4000A LT Panel, Supply of 2500A ACB, Retrofit of 2500A LT Panel, Supply of 3X400Sqmm HT 11KV Al Cable, Supply of 3.5X400Sqmm LT 1.1KV Al Cable, Laying, Testing and Commissioning of 3X400Sqmm Al. cable, Testing and Commissioning of 3.5X400Sqmm Al. cable, Providing of Earth pits with required copper and GI flats, Supply of Cable End terminations HT and LT kits and carrying out HT and LT End Terminations including straight through joints, Shifting of 1600KVA, 1000KVA and 750KVA Transformers
Design and Supply of 11 KV, 630A, 25KA, Erection, Testing and Commissioning of 11 KV, 630A, 25KA, Supply of Earthed armoured, aluminium conductor XLPE Power cable, Laying of Earthed armoured, aluminium conductor XLPE Power cable, Supply and making straight through joint with cast resin compound, Supplying and making end termination with brass compression gland and AI.Lugs, Supply of Control Cable PVC insulated, sheathed, unarmoured, flexible copper conductor Cables, Laying and connectorization of Control Cable PVC insulated, sheathed, unarmoured, flexible copper conductor Cables, Supply part for Maintenance Free Earthing System, Service part for Maintenance Free Earthing System, Supply of 50x6 GI strip, Laying of 50X6 GI strip, Removing and dismantling of Existing HT Panels and shifting to store, Supply and placement of 3 mm Thick Rubber Mat. CLASS B, Supply, Fabrication and installation of MS items, Supply and installation Shock hazard charts complete with frame and glass in English and Hindi, Supply and installation First Aid Boxes, Supply and installation of 5 Kg capacity CO2 type fire extinguishers, Supply and installation of Sand buckets with stand Each with at least 3 sand buckets, Supply and placement of Rubber hand gloves 11 kV grade, Supply and installation of Enamelled caution boards, Supply and installation Discharge rod with earthing facility upto 11 kV grade, Supply of Battery Charger with 24V, 25A FC FCBC, Installation, Testing and Commissioning of Battery Charger with 24V, 25A FC - FCBC, Excavation of cable trenches depth upto 1.5 Mtr
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.