computer servers Average Turn Over of Last 3 Years 17 Lakh (s) Experience with Gov. Required 2 Year (s) Computer Servers ( 5 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Specification Form Factor Rack Rack Size (RU) 2 * Processor Make Intel Intel Max. Number of sockets available on chipset 2 2 Max. Number of sockets populated with processor 2 2 Number of core per Processor 10 10 Processor Configuration E5-2630 v4, 10 core, 2.20GHz with 25 MB smart cache memory, 85 watt E5-2630 v4, 85 watt Chipset compatible with CPU YES * Availability of Co- No * 1/5 Processor If Yes Co-Processor Configuration NA * PCI Slots (Express Gen 3.0) 6 * Type of RAM DDR4 * RAM Size (GB) 256 256 RAM upgradable upto (GB) 1024 1024 DIMM Slots (No.) 24 * Type of Hard Disk Drive SAS, NL SAS SAS Hard disk drive Capacity (GB) 1000 1000 Hard disk drive Speed (RPM) 10K * RAID Controller Cache (MB) 0 * RAID Type 1 * RAID Controller Ports @12 Gbps 2 * Video Controller (support VGA or above resolution) Yes * Keyboard No * Mouse No * Bays (min. 2 internal or more hot plug) 8 * USB Ports (version 2.0/3.0) 4 * Certifications Compliance support by Windows, Red Hat or Novell or Oracle Cluster S/W Yes * DVD ROM (or better) 8x or better * Network Card Supported 1G, 10G * FC HBA Dual port card Available * FC HBA Dual port card Speed 16 * Power Management - * Redundant Power Supply Yes * 2/5 Redundant Fan Yes * Total No of Ports 2 x 400GB SSD * Declare SPEC int_rate_base 2006 ; specfp_rate_2006 for 1, 2, 4, 8 prcessor as applicable SPEC CPU® 2006 benchmark should be 1390 (60% SPECint_rat e_base2006+ 40% SPECfp_rate_base2006) * Server scalability to be achieved within the box without adding nodes Yes * RoHS Compliance Yes * BIS Registration number & its Validity - * Max. power consumption of the system (Watt) 800 * Availability of Type test reports consisting of verification of all the features & functional parameters & environmental tests sequences as under: a Dry heat test (For 16 hrs at a temperature of 45 degree C in accordance with IS: 90 00/part-3/section-5/197 7) b Cold test(For 4 hrs at a temperature of 0 degree C in accordance with IS: 9000/part-2/sec tion-4/1977 c Damp Heat Cyclic Test ( For 2 cycles of 24 hrs at a temperature of 40 degree C & 95% RH in accordance with IS: 90 00/part-5/section-1/198 1) Note:- The server shall be checked for all the parameters before conditioning, After completion of the above environmental tests sequence, with a recovery period of 1 to 2 hrs, the server shall be functional No * Name address of Lab - * Test Report No. date - * Power Supply 230 V +/-10%, 50 Hz * 3/5 On Site OEM Warranty (years) 3 3 (or higher) * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar Jain 122001, Corporate Information Systems Department, Corporate Business Technology Center, Indian Oil Institute of Petroleum Management Complex, 83, Institutional Area, Sector-18 5 15
Loading…