Loading…
Loading…
1,529 results • Best match
MCCB with adjt rang 4 pole 25 KA 200 Amp ISI Marked, Cold shrinkable outdoor joint kit 240mm 11KV ISI Marked, MCCB 250 Amp 50 KA 4 Pole ISI Marked, LED Lamp 12 Watt ISI Marked, Plug socket outlet industrial type 250V with MCB SPN 32 Amp ISI Marked, ... Marked, MCCB with ... Marked, MCCB 100 ... Marked, MCCB 35 ... socket distribution board ISI ... Marked, MCCB 100 ... socket distribution board ISI ... enclosers distribution board for ...
Taking down MCB distribution boards, Supply and installation smart single phase meter, Supply and installation smart three phase meter, Supply and configuration of the web based software, Provision child server and main of infrastructure for vending ... MCB distribution board , ... Amp MCCB , ...
Taking down MCB distribution boards, Supply and installation smart single phase meter, Supply and installation smart three phase meter, Supply and configuration of the web based software, Provision child server and main of infrastructure for vending ... MCB distribution board , ... Amp MCCB , ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), LED Tube Light (Retrofit Type) (Q2), LED Batten (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5 Section 3) (Q3), LED Luminaire for Floodlight (V2) Conforming to IS 10322 (Part 5/Section 5) (Q3) (3 (3 ))
XLPE Cables for Working Voltages from 3.3 kV up to and Including 33 kV as per IS:7098 Part 2, LED Luminaire (for Flood Light), Power Cable For Direct Burial Xlpe Ugac Cable-IS: 10418, Molded Case Circuit Breakers (Mccb)-IS/IEC:60947, dusk to dawn controller-Sensitive switch, Lighting Pole Or Post And Hardware- Tubular Street Light Poles-IS 2713/80 Bidder Turnover (Last 3 Years) 4 Lakh (s)
LED Luminaire For Floodlight Conforming To IS 10322 (Part 5/Section 5) (V3) (Under BIS Scheme - II) (Q2), LED Batten Light (LED Tube Light) (V2) (Q2), Miniature Circuit Breakers (MCB) for AC Operation Marked To IS/IEC 60898 (Part 1) (Q2), Moulded ... ( MCCB ) ...
Construction of extension building of B.R. Ambedkar Hall, MS Hall, SN and IG Hall and vertical extension of MMM Hall at IIT Kharagpur including Internal Water Supply, Sanitary Installations, Internal Road, Drainage, Internal Electrical Installation, ... 33kV VCB unit ...
LED Bulb with Battery as per IS 16102 (Q3), Self Ballasted LED Lamps for General Lighting Services (V2) Conforming to IS 16102 (Q2), LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3), LED Batten (Q2), LED ... ( MCCB ) ...
LED Batten (Q2), Non - Modular Piano Type Domestic Electrical Switches as per IS 3854 (Q3), Modular Piano Type Domestic Electrical Switches as per IS 3854 (Q3), Piano Type Modular Domestic Electrical sockets - IS 1293 (Q3), Piano Type Modular ... ( MCCB ) ...
LED Batten Light (LED Tube Light) (V2) (Q2), LED Luminaire (Recessed Luminaire) (Ceiling Light) Conforming To IS 10322 (Part 5/Section 2) (V4) (Under BIS Scheme - II) (Q2), MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 ... ( MCCB ) ...
25 KA 200 Amp ISI Marked, Cold shrinkable outdoor joint kit 240mm 11KV ISI Marked, MCCB 250 Amp 50 KA 4 Pole ISI Marked, LED Lamp 12 Watt ISI Marked, Plug socket outlet industrial type 250V with MCB SPN 32 Amp ISI Marked, Cold shrink cable joint kit ... Marked, MCCB with ... Marked, MCCB 100 ... Marked, MCCB 35 ... socket distribution board ISI ... Marked, MCCB 100 ... socket distribution board ISI ... enclosers distribution board for ...
M and L for connecting testing the solar DC, M and L for removing old unserviceable self starter, M and L for repair of 33 kv VCB panel, Supplying installing testing and commissioning, M and L for disconnecting electric supply and taking, Disconnecting and taking out existing cable HT 33 KV, Disconnecting and taking out existing cable HT 11 KV, M and L for connecting testing the solar DC inverter
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 10 No of Phase - Three Phase ENGINE Make of ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 30 30 No of Phase - Three Phase ENGINE Make of ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
for EWC, PVC 40 mm dia short L bend pipe for EWC, Window glass panes 42 cm x 27 cm, GI socket 25 mm, GI Elbow 25 mm, GI nipple 15 x100 mm, GI union 25mm, GI tank nipple 20 mm, GI Nipple 15 x 150 mm, GI Elbow 20 mm, Window glass panes 18 mm x 36 mm, ... socket distribution board , ... socket distribution board , ... mm, MCCB 400Amp ... KA, MCCB with ... V, MCCB 250 ... Roll, MCCB 35 ... E, MCCB 100 ... T, MCCB 25 ... freon, MCCB TPN ... way distribution board for ...
Supply, fabrication and construction of copper plate earthing details of electrodes and earth pit at Akashvani Ramgarh, Jaisalmer, Rajasthan, Providing of 50mmx3mm copper strip and making grid of above earthings by interconnecting earth electrodes ... and LT panel and ...
Copper Alloy Fancy Taps for Bathroom as per IS 8931 (Latest) (Q3), Stainless Steel Wire Shelving Rack Or Pot Rack (Q3), Bathroom or Toilet Mirror (V2) (Q4), Wire Mesh Fabric or Cloth (V2) as per IS 1568 (Q3), MCB - Miniature Circuit - Breakers for ... ( MCCB ) ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), LED Luminaire (for Flood Light) as per IS 10322, IS 16107 (Q3), PVC Copper Cable Single Core and Multi Core Circular Sheathed Cord with Flexible Conductor (V2) as per IS 694 (Q2), PVC Insulated Copper Cable Single and Multi - Core Circular Sheathed Cable with Flexible Conductor (V2) as per IS 694 (Q2)
MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), PVC Insulated Copper Cable Single and Multi - Core Circular Sheathed Cable with Flexible Conductor (V2) as per IS 694 (Q2), PVC Aluminium Cable 1 Core and Multi Core Circular Sheathed Cable with Rigid Conductor as per IS 694 (Q3), XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2)
Modular GI Box with modular base and cover plate, Modular Switch, Modular Socket outlet, TV antenna socket outlet, Bell push, Modular blanking plate, Angle holder, 3 Pin 5A ceiling rose, ceiling fitting, Call bell, Light fittings, Exhaust fan, 25A ... MCB distribution board , ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 (or higher) No of ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Average Turn Over of Last 3 Years 30 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY ... - CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 62.5 62.5 No of Phase - Three Phase ENGINE Make of ... - CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 40 40 (or higher) No of Phase - Single phase, Three ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 320 320 (or ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 100 100 No of Phase - Single phase, Three Phase ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 250 250 (or ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 200 200 (or ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 40 40 No of ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 40 40 No of Phase - Single phase, Three Phase ENGINE ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Average Turn Over of Last 3 Years 50 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values ... * CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 100 100 No of Phase - Three Phase ENGINE Make of ... - CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 25 (or higher) No of Phase - Single phase, Three ... - CONTROL PANEL Control Panel Manual ... of Control Panel IP ...
diesel generators- DG Sets Diesel Generators- DG Sets ( 15 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 10 (or ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
MOTOR REPAIR CHARGES, PI Testing, IR Testing, Thermography, ACB VCB tesing, Relay testing, Transformer Oil filtration and oil sample testing, Insulation mat, LOAD TESTING OF BATTERY BANK, Calibration of equpiments, EXPLOSIVE METER MULTI GAS, ... TESTING, VCB bottle, ... OF VCB , ...
LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5/Section 3) (Q3), LED Batten (Q2), LED Luminaire for High Bay Lighting (Q3), LED Luminaire for Floodlight (V2) Conforming to IS 10322 (Part 5/Section 5) (Q3), LED Luminaire ... ( MCCB ) ...
MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), LED Luminaire for Road and Street Lights (V2) Conforming to IS 10322 (Part 5 Section 3) (Q3), PVC Insulated Copper Cable Single and Multi - Core Circular Sheathed Cable with Flexible Conductor (V2) as per IS 694 (Q2), Wire Mesh Fabric or Cloth (V2) as per IS 1568 (Q3), Stainless Steel Wire Shelving Rack Or Pot Rack (Q3), Bathroom or Toilet Mirror (V2) (Q4) (3 (3 ))
Calcium Hypochlorite Granules (65-70%) (Q2), Fixed Capacitors (Fixed Capacitor For Single Phase Ac Electric Fan)-IS: 1709:1984 (Q3), Miniature Circuit Breakers-IS 60898-1:2002 (Q3), Molded Case Circuit Breakers (Mccb)- IS/IEC:60947 (Q3), Steel Pipes Fitting-IS 1239 (Q3), Commercial CPVC Pipe Fittings (Q3), gate valve - as per IS 778 (Q3), Sluice Valves-IS 14846 (Q3), Heat Shrink Straight Through Joint-IS-60840 (Q3), Power Cable For Direct Burial Xlpe Ugac Cable-IS: 10418 (Q3), Ball Valve-IS 9890 (Q3), Heat Shrink Termination Kit-IS-60840 (Q3)
LED light suspended hexagonal profile PS 36W, LED light column type 3 meter height 40 watt, LED light column type 3 Mtr height, PVC Cable Junction box, PVC insulated and FRLS round sheated, LED warm white flame proof light, Flame proof LED linear ... MCB Distribution board , ...
diesel generators- DG Sets Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 3 Year (s) Diesel Generators- DG Sets ( 9 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values ... * CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
flanged, PVC Connection 15 x 450 mm, PVC Connection 15 x 600 mm, PVC Flushing Cistern 10 ltr cap, PVC health faucet 15mm with tube 1 point 5 mtr and hook, PVC Jet spray 15mm with 1 point 5mtrs connecting tube, PVC Overhead Shower Round 3 inch, PVC ... 25A, MCCB 04 ... KA, MCCB 04 ... KA, MCCB 04 ... Volts, MCCB 3 ... Amp, MCCB 4 ... Amp, MCCB 4 ... KA, MCCB 4 ... mtr, MCCB 4 ...
Heating Element 2 KW CT, Fuse wire copper 6 Amp, Fuse wire copper 100 Amp, Heating Element 1.5 KW CT, Capacitor 45 MFD for AC, PVC casing caping 20 mm, Capacitor 50 MFD for AC, Fuse wire copper 20 Amp, Fuse wire copper 25 Amp, Fuse wire copper 63 ... KW, APFC Panel Relay ... Stage, APFC Panel Relay ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), Piano Type Non Modular Domestic Electrical sockets - IS 1293 (Q3), Piano Type Non Modular Domestic Fan Regulator as per IS 11037 (Q3), Non - Modular Piano Type Domestic Electrical Switches as per IS 3854 (Q3), HYDRAULICALLY REGULATED DOOR CLOSERS (Q3), Flushing Cistern (Q3), Towel Rail/Ring/Rack/Hooks for Bathroom (Q3), Waste Fittings for Washbasin and Sinks as per IS 2963 (Q3)
Material and Labour for disconnecting the cabel connection from conventional starter complete all as specified and directed, Material and Labour for taking down conventional starter and removing to MES store for issue as sch of credit complete all as ... and MCCB complete ...
XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1) (Q2), Piano Type Modular Domestic Fan Regulator as per IS 11037 (Q3), call bell (Q3), LED Bulkhead Light (Q3), Towel Rail/Ring for Bathroom (Q3), Towel ... ( MCCB ) ...
Rolling Shutter Safety Brake, Rolling Shutter Wind Lock Guide Channel, Rolling Shutter Wind Locks, Rolling Shutter Connecting Sheet, Roller Cage, Roller Shaft MS Pipe, Rolling Shutter Spring, Ball Bearing, Rolling Shutter Laths, Rolling Shutter U ... Shutter Control Panel Box ...
Supply of 32 A 3 pin Industrial plug top, Supply of MCB SP 6 32 Amp, Supply of MCCB TPN 63 Amp, Supply of MCCB TPN 32 Amp, Supply of MCB 32 Amp Double Pole, Supply of Plug top 3 pin 16 Amp, Supply of 9 watt LED mirror light, Supply of 20 watt LED tube light, Supply of 9 Watt LED Bulb, Supply of Single core 1 5 sqmm copper conductor, Supply of Single core 2 5 sqmm copper conductor, Supply of 2 0 core X 2 5 sqmm copper conductor, Supply of 2 0 core X 1 5 sqmm copper conductor, Supply of 2 0 core X 10 sqmm Aluminim cable, Supply of 45 watt LED Street Roadway lighting, Supply of single pole 6 A Piano type switch, Supply of single pole 16 A Piano type switch, Supply of 6 pin 16A Piano type socket, Supply of 3 pin 6A plug top, Supply of LED Indication Lamp, Supply of 05 step Electronic fan regulator, Supply of 12 Volt 150 AH lead acid battery, Supply of 12 Volt 100 AH lead acid battery, Supply of 12 Volt 35 AH lead acid battery, Supply of Electrical Insulation rubber mats of Class A, Supply of 16 A Extension Board Bid Number ( ) : GEM/2025/B/6000752 Dated : 27-02-2025 Bid Document 1/24
diesel generators- DG Sets Experience with Gov. Required 1 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 20 20 No of ... N/A CONTROL PANEL Control Panel AMF ... of Control Panel IP ...
Harpic 750 ml, Broom Large, Colin, Air Wick Sachet, Air Freshner Spray, Phenyle White, Phenyle Black, Bamboo Stick 8 Ft, Bamboo Stick 20 Ft, Fawdi for Sewer Cleaning with Iron Handle, Grinding Wheel Paper 60 No, Pencil Cell AA, Lancer Set, Almirah ... Colour, MCCB 100 ... Pole, MCCB 200 ... Pole, MCCB 400 ...
Rotational Moulded Polyethylene Water Storage Tanks as per IS 12701 (Q3), Molded Case Circuit Breakers (MCCB) as per IS/IEC 60947 (Q3), MCB - Miniature Circuit - Breakers for A.C. Operation as per IS/IEC 60898 (Part 1) (Q2), Non - Modular Piano Type Domestic Electrical Switches as per IS 3854 (Q3), Piano Type Non Modular Domestic Electrical sockets - IS 1293 (Q3), Piano Type Modular Domestic Fan Regulator as per IS 11037 (Q3), Piano Type Non Modular Electrical Switch Socket Combination as per IS 3854 and IS 1293 (Q3), PVC Insulated Unsheathed Cable with Flexible Conductor as per IS 694 (Q2), HYDRAULICALLY REGULATED DOOR CLOSERS (Q3), Flushing Cistern (Q3), Curtain Pipe, Sider and mounting bracket (Q4), Bathroom or Toilet Mirror (V2) (Q4)