125KW /167HP motor stater control panel (Auto transformer type) Make:- JSL ,MEI ,L&T, ABB , BCH , C&S or similar. Warrenty as per IRS Terms & conditions Offer: Make Brand C&S Model No BE3-F185N160. M
Automatic change over control panel for Colour Light Signalling system of 10 KVA 60A capacity. Detail specifications are as per RDSO specification no.TI/SPC/PSI/CLS/0020(12/02)(with A&C slip No. 1 to
Automatic changeover control panel for colour light signaling [CLS Panel], with three source of supply as per RDSO Spec. No. ETI / SPC / PSI / CLS / 0020 [12/02] with A7C SLIP No1to 4 RDSO Drg No ETI/
Alternator Earth Leakage Relay(residual Current Monitor Relay), Power Supply: 12-48V AC/DC confirming to IEC 60947-2/M suitable for DG Set Power and Control Panel for EOG LHB Power Car Similar to Cat
Automatic change over control panel for Colour Light Signalling system of 10 KVA 60A capacity. Detail specifications are as per RDSO specification no.TI/SPC/PSI/CLS/0020(12/02)(with A&C slip No. 1 to
Engine Control Panel of M/S CATERPILLAR Part no-CAT-3591431, For Engine Model No.-3508 B, 1400 HP DEMU DPC, (Changed to DISPLAY GP-E, CAT Part No.-5786919 & HARNESS AS, CAT Part No.-5932899).
Automatic change over control panel for Colour Light Signalling system of 10 KVA 60A capacity.Detail specifications are as per RDSO specification no.TI/SPC/PSI/CLS/0020(12/02)(with A&C slip No. 1 to 4
Locking arrangement for AC control panel , Material of plate stainless steel grade - 304(IS: 6911) and other Part- stainless steel (IS: 1367 pt. 14) conforming to Dy,CEE/W/LLH's Drg No. LED/AC/4/932
Repairing of A/Y make 3.3kV-300A VCB, CTR-100/5A, sl.no.4009851 at Begunia sub-station
Repairing of AndrewYule make VCB Sl No- 1596 with replacement of CTs OF 25MVA Substation, S.B. Project.
PROVN OF 11 KV HT VCB AND HT UG CABLE AT HALDIA UNDER GE (I) (CGN) KOLKATA
REPAIR / MAINTENANCE OF HT TRANSFORMER, CAPACITOR, PANEL VCB/OCB/VLE AND ALLIED SERVICES UNDER GE(C) KOLKATA
Magnet valve assembly (R) to Schneider part no. VDRMO0150-01 for VCB type22CB of electric locomotives.Make: Schneider
Air Filter for Air Control Assembly, VCB Type No - 22 CB To M/s.SCHNEIDER'S Part No- 5110010.
Piston assembly for single bottle VCB. Type -22CB as per schneidor part no. 5540020. MAKE/BRAND: Schneider
Lifting Sling for VCB (4 ton SWL) as per drawing no. TRS/GMO/E4/G-9/036.
EARTHING SWITCH FOR VCB -WITH LOCKING ARRANGEMENT TO CLW SPEC. NO. CLW/ES/3/0010, ALT.- D.
EARTHING SWITCH FOR VCB -WITH LOCKING ARRANGEMENT TO CLW SPEC. NO. CLW/ES/3/0010 ALT.- D.
Relay Valve Assembly For M/s. Areva/Schneider make 22CB type VCB, Code: 5570000. Make: Areva/Schneider.
Relay Valve Assembly For M/s. Areva/Schneider make 22CB type VCB, Code: 5570000. Make: Areva/Schneider.
Male Connector with 25 pins for VCB, as per Schneider code no.5510301. Accepted Make/Brand: " Schneider".
Supply of special service kit for SEIL make VCB CB22 as per annexure attached. Firm's offer:- Schneider
AIR FILTER FOR AIR CONTROL ASSEMBLY, VCB TYPE NO - 22 CB TO M/s.SCHNEIDER'S PART NO.- 5110010.
AIR FILTER FOR AIR CONTROL ASSEMBLY, VCB TYPE NO - 22 CB TO M/S.SCHNEIDER'S PART NO- 5110010.
Relay Valve Assembly For M/s. Areva/Schneider make 22CB type VCB, Code: 5570000. Make: Areva/Schneider.
REPAIRING OF FEEDER PILLAR BOX LOCATED AT DIFFERENT LOCATIONS IN WARD NO-71 UNDER BR-IX.
Emergent requirement of new Cable and allied work from Substation to Feeder Pillar at ALIPURDUAR DH.
SHIFTING OF FEEDER PILLAR BOX LOCATED AT DIFFERENT LOCATIONS IN WARD NO-74 UNDER BR-IX.
SPL REPAIR FOR REPLACEMENT OF SOLAR LIGHTS AND MISC WORK AT E/M INSTALLATIONS, RAIL COLONY, DHARAMPORE COLONY, NEW COLONY AND SPL REPAIR TO REPLACEMENT OF LT PANELS, EARTHING, CABLE, LT POLES AND MISC WORK AT E/M INSTALLATION AT RAIL COLONY
Thorough repairing with replacement of damaged essential components of the APFC panel at Rajapur and Rajdanga drainage pumping station.
12 KV, 400A Indoor Type Series Trip Metering Switchgear Panel with VCB including all accessories for Indoor Installation with CTR 50_25_5_5A and 100_50_5_5A
Servicing with replacement of defective components of 6kv. HT VCB switchgear for 187.5 Kw 75 cusec capacity pump unit no B at BDPS
Complete servicing and overhauling of HT switchgear VCB and oil type Transformer along with allied works at Trenching Ground LS under GRBU(S_D)
servicing with replacement of defective components of 6kv HT VCB switchgear for 330 Kw 240 cusec KSB make submersible pump unit at BDPS
RET 670(87, 64R) MAIN PROTECTION RELAY FOR GT-UT CONTROL PANELS (600 MW), RET 670(87) MAIN PROTECTION RELAY FOR GT-UT CONTROL PANELS (600 MW, RET 670(87, 51, 51N, 24) MAIN PROTECTION RELAY FOR GT-UT CONTROL PANELS (600 MW)
4.7 OHMS, 500 WATTS CORRUGATED WIRE WOUND RESISTANCE SUITABLE FOR RC DAMPING NETWORK OF VCB, WITH SUITABLE FIXING CLAMP AS PER VCB SPEC. NO. CLW/ES/C/47 AND DRG NO. CLW/ES/SK-5/C-47. Note: 1) This it
AOH Kit for Rotex Make EP valve Model No. 3327 fitted on AAL Make VCB type VCBA 25.10 Tr single bottle VCB (08 Items 17 Nos.) as per attached Annexure-'A'. ACCEPTED FIRM"S OFFER: AOH KIT OF VALVE MODE
Repairing of Mine Line make 300A-550V ACB switch for 50kVA-550V/440V lighting transformer at GM Bungalow Begunia Project sub-station under CV Area.
Drawing 440V, 3 Ph, 5 wire Aerial Bunch cable wire along with LT Switchgear installation in Dalmia Railway Siding, Bonjemihary OCP under Salanpur Area.
REPAIR/MAINT OF AIR CIRCUIT BREAKER, LT SWITCHGEAR, CONTROL RELAYS AND OTHER CONNECTED WORK AND COMPREHENSIVE MAINT OF SWIMMING POOL AT AF STN HASIMARA
Testing of Transformer and Switchgear of Pit No. 5/6 of Madhaipur Colliery and Pit No. 9 of Madhaipur Colliery, ECL under Pandaveswar Area
Replacement of power supply cable and allied switchgear. SH Provision of Battery operated Tug charging points and alternate source of different ESS at NIPTB.
Supplying and Installation of Dehumidifier of reputed make in 33kv Switchgear room of Kona 132kv GIS Substation under Howrah Area Office, WBSETCL (2nd Call)
Supply and delivery of Mobile Filtration Plant suitable for treating Transformer and Switchgear oil of capacity 2000 LPH at Rammam Hydel Project, Stage II
Push button reset vigilance control as per CLW Spec. no. CLW/ES/3/0072/E or latest. Firm's offer: TEKMEC SWITCHGEAR&CONTROLS, Brand TEKMEC
Push button reset vigilance control as per CLW Spec. no. CLW/ES/3/0072/E or Latest. Firm's offered -TEKMEC SWITCHGEAR&CONTROLS,Brand TEKMEC
DC Drive with Control Panel for Stacker cum Reclaimer of CHP U# 1-4, MTPS, DVC, Supervision of Installation & Commissioning of DC Drive system MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and ... with Control Panel for ...
Day to Day Emergent Repair and maintenance of Substation, HT Overhead, HT and LT Panel, LT Cables at PTS Salua in the district of Paschim Medinipur for a period of 365 days From 01.04.2021 to 31.03.2022. (1st Call)
Day to Day emergent repairing and maintenance of Substation, HT and LT Panel, LT Overhead, Street Light, Building roof top lights, Cables within EFR 1,Salua for a period of 365 days (From 01.04.2021 to 31.03.2022). (1st Call)
Annual Electrical maint of 11 KV Sub-Station no 3 HT Switches Gears, LT panel Boards, Over Head Lines , UG Cables, all Electrical Installation of Office Buildings, residential buildings of Latbagan at Barrackpore 01.04.2021 to 31.03.2022. (1st call)