Loading…
Loading…
2,576 results • Best match
HVPNL has decided to creation of one number 33 KV line bay at 132 KV substation Mundlana on chargeable basis for providing 33 kV voltage level connectivity to M/s Adani Wilmar Ltd., Mundlana as a deposit work
Providing of oil Plugging compound and plugging of oil leakage of TF T1 100 MVA 220132Kv and TF T2 100 MVA 220132KV bearing SR No S-29999 and S 30000 Make Areva installed at 220 KV Substation Nuna Majra
Providing 3rd additional 12.5/16 MVA 66/11kV transformer and extension of 66kV double bus bar arrangement having 0.4 SQ. inch ACSR conductor from Bay C-4 to C-1 with allied electrical equipment/structure at 66kV Substation Farukhnagar
Design, Supply and Erection of 33 11 KV Outdoor Substation for Dhanwapur STP Gurugram by providing 2 x 10 12.5 MVA 33 11 KV transformer and its associated 33KV feeder circuit line though underground cable from Sector 107 220K
Moisture cleaning and insulation coating of 11kv VCB Panels11kv bus bar posts clusters at 132kv sstn Jhajjar and Beri B plugging of oil leakage of 2025 MVA 13233 KV TF T-3 installed at 132 KV SubStation HVPN Matanhail
Augmentation of 132 KV substation HSIIDC Bahadurgarh from 1x2025 MVA 13211 KV plus 1X31.5 MVA 13211 KV to 1x2025 MVA 13211 KV plus 1x31.5 MVA13211 KV plus 2x4050 MVA 13233 KV Transformers with 8 nos outgoing 33 KV Line bays.
Work of water proofing treatment to stop water leakage on the roof of admn block building situated at SLDC Complex, BBMB, Chandigarh and on the roof of office of OandM Division and officers rest house situated at 220KV Substation, BBMB, Dhulkote.
Augmentation of 22o kv substation Deroli Ahir from (1x160 plus 1x100MVA), 220/ 132kV plus 1x100MVA 220/33kv T/F to (1x160MVA plus l x l00MVA) ,220/132kv plus 2 x 100MVA 220/33kv T/F in FY 2022-23. No
Special Estimate for attending of pending observations On risk and cost of MS ILand FS at 132 KV SubStation Garnawathi and Creation of one no 132 KV bay at 132 KV SubStn Sector3 Rohtak for accommodating 132 KV DC Nonand Kharkhod
1. Repair of Electrical Substation Room. 2. Providing new transformer with foundation. 3. Supply and Installation of DG sets. 4. Supply and Installation of LT Panel. 5. Supply and Laying of necessary HT and LT Cables. 6. Repair of street light
estimate has been prepared for construction of 6 feet high precast boundary wall around the HVPNL land of 220 kV substation Nonand. Precast boundary wall is to be constructed in approximately 885 mtr length around the periphery of the HVPNL land.
Augmentation of 220kv substation Salempur from 2x100MVA 220/66KV plus 2X12.5/16MVA 66/11kv to (2x100MVA plus 1X160MVA) 220/66kv plus (1x25/31.5 plus 1x12.5/16) MVA 66/11kv transformer in FY 2018-19 Regarding supply and spreading of gravel
MOEI & fans S/Stn DG set p/set at CIB & RC NH-IV FAridabad. 2) MOEI & Fans , C/light at CIPMC , PPQS machinery store & training hall at NH-IV Faridabad Subwork/Packages: Operation & maintenance of su substation electrical installation & DG set)
Reconductoring Package- OH01 for Reconductoring of various 132kV S/C transmission line and associated substation work under North Eastern Region Expansion Scheme-XX (NERES-XX), North Eastern Region Expansion Scheme-XVIII (NERES-XVIII) and Eastern Region Expansion Scheme -XXXIII (ERES- XXXIII)
Providing Services of Computer Operators, Watchmen/Chowkidar in the office of EE Sonipat, Sonipat Division & Sub division under EE Sonipat, CPWD. 1. Chargeable to contingencies of works i.e C/o of I.I.I.T Campus at Sonepat Haryana SH: C/o ... Elect Substation including ...
As per NIT Documents
Job work for Design Supply and erection of transformer of standard make Required 25 KVA 110 433 KVA rating outdoor type 11 KVA VCB panel, G.O. switc H. Pole HT metering panel APFC panel battery charges 11 KVA substation entire cable netwo
Creation of 132 kV double bus arrangement along with 132 kV bus-coupler at 132 kV substation Sector 27 and 28, Hisar. (Balance left out work i.e 1 no BT-6 Tower ,3 no 132 KV SF-6 Breaker foundation and site surfacing)
Surveying charges for Creation of 220 KV DC line from new approved 220kV Substation Nain to MS IOCL with 0.5sq ACSR conductor approximate 22.5 Kms with overhead arrangement in FY 2023-24 and Survey charges for Augmentation of conductor of 220 k
Work for replacement of old and obsolete 132KV TF C and R panel controlling 132/11KV, 10/16MVA, T-1 andT-4 T/Fs,132/33KV, 40/50MVA T-2and T-3 T/Fs and 132KV Sewah - Ganaur line at 132KV substation, Ganaur
Replacement of ACSR ZEBRA (0.4 Sq. Inch) conductor of 66 KV Main Bus-Bar and Jack Bus Bar along with connected jumpers of 66 KV equipment with new Twin ACSR Zebra (0.4 Sq. Inch) Conductor and various clamps at 220 KV Substation, Tepla
Work for augmentation of 132 KV S/Stn Begga from 2x40/50 MVA, 132 /33 KV transformers to 3x40/50 MVA 132/33 KV transformer by providing additional 1 No. 40/50 MVA 132/33 KV T/F at 132 KV substation Begga
Estimate for augmentation of 220Kv substation sampla from 3x100MVA 220/132KV to 3x100 MVA 220/132 KV plus 1x100MVA 220/33KV along with one 33KV IC Bay ,6 33KV O/G bay and 1 33 kv Capcitor bank at 220KV substion sampla
Survey charges for Creation of 220kV D/C line with Twin ACSR Moose Conductor on D/C lattice towers/Multi circuit towers/Monopoles/Cable/as the case may be from 765KV PGCIL Bhiwani to proposed 220kV AIS substation Kalanaur (approx. 35 kms.)
Estimate for augmentation of 220 kv Substation Sec-58, Faridabad from 2x160 MVA , 220/66 kv plus 2x25/31.5 MVA, 66/11 kv T/Fs to 2x160 MVA , 220/66 KV plus 3x25/31.5 MVA 66/11 kv T/Fs as per revised GELO
This Special estimate has been framed to cover the cost of material, labour, TandP and other expenditure to be incurred for providing one no. 33 kV bay to accommodate 2nd circuit of 33kV Line for 33kV Substation Beholi at 132 kV S/Stn. HVPNL, Beholi
This Special estimate has been framed to cover the cost of material, labour, TandP and other expenditure to be incurred for providing one no. 33 kV bay to accommodate 2nd circuit of 33kV Line for 33kV Substation Mandi at 132 kV S/Stn. HVPNL, Naultha
This Special estimate has been framed to cover the cost of material, labour, TandP and other expenditure to be incurred for providing one no. 33 kV bay to accommodate 33kV Line for 33kV Substation Bhudshyam at 132 kV S/Stn. HVPNL, Naultha Panipat as
Prov. HT-LT line, Pole mounting Substation with 01 year illumination with 3 years defect liability period of complete system and LED Flood lights on site replacement free of cost and maintenance ON-OFF free of cost for 1st year and at labour ra
Design Supply Erection Testing and Commissioning of 66 6.6 kV Substation at WTP Chandu Bhudhera Gurugram by constructing 4 nos. of Bays with a provision of 2 nos. of 10 MVA 66 6.6 kV Transformers and 2 nos. 3000 kVA 6.6 .415kV Transformers VCB Panels
Augmentation of 220kV substation Sirsa from 2x100MVA 220/132kV plus 1x20/25MVA 132/33kV plus 2x40/50MVA 132/33kV plus 1x10/16MVA 132/11kV transformers to 3x100MVA 220/132kV plus 1x20/25MVA 132/33kV plus 2x40/50MVA 132/33kV plus 1x10/16MVA 132/11kV tr
Augmentation of 132kV substation Sector-3 Rohtak from 1x40/50MVA, 132/33kV plus 1x20/25MVA, 132/33kV plus 1x10/16MVA, 132/11kV plus 1x16/20MVA, 132/11kV to 1x40/50MVA, 132/33kV plus 2x20/25MVA, 132/33kV plus 1x10/16MVA, 132/11kV plus 1x16
Supply of material, erection, testing, commissioning (including civil works) of 4 nos. new 33/11 kV Indoor AIS S/Stns at Sector-79, Sector-84, Sector-86 and Sector-88, Faridabad to be fed from 220/33 kV substation, Sector-78, Sector- 89 under RDSS
As per NIT
Emergency Restoration System (ERS) suitable for 400kV Transmission Lines
Augmentation of 132kV substation Thana from (1x40/50MVA, 132/33kV), (1x16/20 plus 1x10/16) MVA 132/11kV transformers to (1x40/50 plus 1x20/25) MVA, 132/33kV plus (1x16/20 plus 1x10/16) MVA, 132/11kV transformers in FY 2024-25. Along with the income
Estimate for creation of 02 Nos. 66 Kv bays at 400. Kv Nawada Substation to accommodate 66 Kv Nawada-Sec 64 D/C line, out of which 1 No. 66 Kv bay would be in back to back arrangement by HVPNL as per the revised GELO.
Creation of LILO of one Ckt. of 220kV D/C Daultabad-IMT Manesar Line at 220 kV Substation Sector-99, Gurugram (alternate to circuit which is LILOed at Sector-85, Gurugram) with 0.4 sq inch ACSR Conductor by using 220 kV D/C/ M/C / Monopole towers
Augmentation of 132 kv substation Haluwas from 1x20/25 MVA, 132/33 kv plus 1x10/16 MVA , 132/11 kv T/Fs to 2x20/25 MVA , 132/33 kv plus 1x10/16 MVA, 132/11 kv T/Fs along with yard extension in FY 2023-24.
Deposit estimate for creation of 2 Nos 220 KV line bays at 220 KV SStn Bhadana for feeding 220 KV Sstn of M/s METL Dadri Toe Jhajjar. Deposit estimate for creation of one no 132 KV bay at 132 KV substation Mundlana to accommodate feeding of 132
Augmentation of 132 kV substation Tosham from 1x20/25 MVA, 132/33 kV plus 1x10/16 MVA, 132/11 kV T/Fs to 2x20/25 MVA, 132/33 kV plus 1x10/16 MVA, 132/ 11 kV T/Fs for redundancy by HVPNL in 1st half of FY 2024-25.
Augmentation of 220 kV substation BBMB Charkhi Dadri from 2x100 MVA, 220/132 kV T/F to plus 1x (160 plus 100) MVA 220/132 KV T/Fs in FY 2019 20 subject to concurrence of BBMB. (Construction of Radiator, Oil drainage system, NCT, Site surfacing and dr
Repair and configuration of BCU of 220/132kV, 100 MVA T/F T-1, configuration of BCU of 33kV bus coupler, REF relays of 220/132kV, 100 MVA T/F T-1 and 220/33kV, 100 MVA T/F T-2 at 220KV Substation Chormar- Work for SAS integration.
The work for creation of one no. 33 kV bay at 132 KV Substation Naultha to accommodate shifting of 33 kV S/Stn. Naraina (20 MVA) from 400 kV S/Stn. Sewah Panipat by HVPNL was approved as per CE planning HVPNL Panchkula approval, vide memo no-R-1876/c
ARMO Electrical Generator at NSTI Office Building at Panipat, Haryana. (SH: Replacement of existing 11 KV HT Panel i/c defective G.O switch etc.). Subwork/Packages: ARMO Electrical Substation Generator at NSTI office Building at Panipat, Haryana. (SH: Replacement of existing 11 KV HT Panel i/c defective GO switch etc.).
Augmentation of 220 KV Substation Bhiwani from 3x100 MVA 220/132 KV plus 2X10/16 MVA 132/11 KV T/Fs to (2X100 plus 1X160) MVA plus 1X20/25 MVA 132/33 KV plus 2X10/16 MVA, 132/11 KV T/Fs subject to commissioning of connectivity from 765 KV PGCIL Bhiwa
Creation of 33 KV bay at 132 KV substation Jundla to accommodate the creation of 33 KV S/Stn Bansa, Chirao mod and capacitor bank and Augmentation of 132 KV Jundla from 1x40/50MVA 132/33 KV plus 2x16/20MVA 132/11 KV T/Fs to 1x40/50MVA plus 1x20/25 MV
Augmentation of 220 KV substation Dadhibana from 2x100 MVA, 220/132 KV plus 2x10/16MVA, 220/33 KV T/Fs to (1x100 plus 1x16) MVA, 220/132 KV 2 2x100 MVA, 220/33 KV T/Fs subject to commissining of 220 KV D/C PGCIL Bhiwani-Dadibana line in FY 2024-2
Augmentation of 220 KV substation Bhuna from 3x100 MVA, 220/132 KV plus 2x20/25 MVA, 220/132 KV plus 1x12.5 MVA , 132 /11 KV T/F to (2x100 plus 1x160)MVA ,220/132KV plus (2x20/25)MVA,132/33KV plus 1x12.5 MVA,132/11KV T/Fs in 1st half of FY 2024-25
Augmentation of 132 kV substation Jhojhu Kalan from 1x20/25 MVA, 132/33 kV plus (1x16/20 plus 1x10/16) MVA, 132/11 kV T/Fs to 2x20/25 MVA, 132/33 kV plus (1x16/20 plus 1x10/16) MVA, 132/11 kV T/Fs for redundancy subject to augmentation of 220 kV subs