Installation of 2nos VCB for controlling of 2 Nos 11KV feeders feeding power to Topa/Pindra and Kuju/Pundi at near PO Office Kuju Colliery with repairing of VCB Repairing under Murpa Sub-station under GM(K) Unit Kuju Area
Repairing of Breaker Unit Purpose 400 Amps 11KV OCB Switch GEC Make Sl. No. 5863 installed as the 11KV Incomer and Primary controlling breaker for 3.15 MVA 11/6.6 KV Transformer at 6 No. Sub-Station of NT-ST OCP.
Dismantling, repair and erection of non working 200W and 300W L.E.D Flood lights and replacement of rusted and damaged G.I pipe bracket for hanging of the L.E.D lights, Installed at Sub-station, Mines, P.O Office, Excavation, PIT office,and weighbrid
Repairing of 02(Two) Nos.100 Amps and 200 Amps 550 Volt Kilburn Make OCB Switch Sl.No. (i) Joy/5/SW/ OCB/02 (ii) Joy/3/SW/OCB/17 at 5 Pit Sub-Station of Amal. Joyrampur Colliery under Lodna Area..
Erection of steel tubular pole in place of Damaged PCC pole between old MTK and WB No.05 for power supply to weighbridge no. 03 and 05 from 62.5 KVA DG set installed at sub- station, Amrapali OCP, Magadh-Amrapali Area
Repair and maintenance of H.T line 11KV destination free location in lieu of the monsoon preparation of domestic overhead line 2 No. Sub-Station to IBM Colony and Bandh Colony, industrial supply and river side pump house under Kathara Washery
Repairing and re-tensioning of damaged and sagged conductor of 440V O/H line, 4wire for feed power to Damoda Coloney and domestic area for safety reasons and 11KV cable compounding in Damoda Sub-station at Damoda Colliery under Barora Area.
Repairing and straightening of Electric Pipe Pole of 440 Volt Overhead Line at different Places such as Joyrampur Colliery 3 Pit Sub-Station to BR Company and PaniTankee workers quarter repairing clamping welding and fixing with PCC work of Base Port
Repairing of VCB switch Andrew Rule Make, Sl. No.- 2407 3no. Feeder Breaker SOCP sub-station of Muraidih, AMP Colliery, Barora Area and Repairing of VCB starter Prabhu Make, of 4000 GPM pump and motor Jharna Face at Muraidih, AMP colliery.
Repairing/Overhauling and Safety Protection of 1 No.400 Amps 11 KV ECE Make O.C.B. Switch Sl. No. KJ/3 for Power Controlling of 500 KVA 11KV/440 Volt Power Transformer at M.Pit Sub-Station of Kujama Colliery under Lodna Area.
Repairing and maintenance of 10MVA, 33 KV/11 KV transformer with OLTC chamber Sl. No. 12275, Make Andrew Yulefor stopping leakage of transformer oil and rectification of operation problems of OLTC in 4211 main Sub-Station under CHP-CPP, Piparwar area
Providing and fixing of NGR for 02 Nos. 1.6 MVA, 11kV/3.3kV Make Transformer and Switchgear Ltd (Sl. No. 10202 and Sl. No. 10203) installed at Main Sub-station for DGMS compliance of Regulation 103 (1) under Dakra Project, NK Area
Repair, maintenance and shifting of main 6.6kV and 11kV Feeder for jobs like replacement of damaged and rusted poles, maintaining earth continuity and cradling as required for strengthening of 6.6kV and 11kV OHL structure from KDH new sub-station to
Dismantling of 2 core CT, supply and installation of 3 core new CT at 11 KV VCB switch of incomer -02 of transformer no.02 (33KV/11KV, 10MVA) for connection of deferential relay at south loyabad sub-station under kusunda Area.
A)Maintenance of East feeder 3.3KV OH line from Pundi 2.6MVA main sub-station to Bhuiyan Tola under Pundi Project B)Renovation and maintenance of power supply with proper lighting conductor and earthing arrangements at 2 nos. weighbridges Karma OCP
Complete Repairing and Safety Protection of 1 No. H.T. Switch 3.3 KV 400 Amps(M.E.I) Mysore Electrical Industries Ltd. Make OCB Switch for 2 MVA Transformer Secondary Controlling at 6 No. Sub- Station Sl. No. 65/016 at NT-ST OCP.
Supply of Plante type Lead acid battery bank along with their erection and commissioning at Putki Substation.
Rewinding and repairing of ETE make 315 kva 33kv/440v transformer (Sl.no. 5840) at south loyabad substation
Repairing of 11kv 400 amps electroteknica make VCB of sl.no. m-5054 installed at godhur switching substation
Work of Providing antiweed treatment by laying of plain cement concrete alongwith metal/gravel spreading in 33KV switchyard at 132/33KV Grid Sub-Station Namkum.
As per attached NIT
Providing cleaning and fixing rubber mat two no. at sub station unit and main sub station, for safety of view at Bokaro colliery Ocp
Erection, Testing, Commissioning along with Civil works and other associated works for installation of 5MVA 33 kV/11.5KV Distribution transformer at Kumardhubi s/s in connection with creation of 11 KV infrastructure at Kumardhubi Sub-station, DVC
Construction of new 33/11Kv Power Sub Station, Ghato.
Extension of surveillance system for Simra Power Sub-station
AMC OF 11KV ELECTRICAL SUB STATION AT DEP RANCHI.
BITUMINOUS FELT FOR (1). D.G. STATION SWITCH GEAR ROOM, (2). 2MVA TRANSFORMER SHED NEAR COLLIERY SUB-STATION, (3). TSU TRANSFORMER, SWITCH ROOM OF 20 NO. WINDING ENGINE, (4). SUBMERSIBLE CONTROL PANEL AND SWITCH SHED AT MUR. 20/21 PITS UNDER WJA,
Erection of pole, conductor dismantling, stay fitting etc at different places of colonies Sub station under, Township WJ Area
REPAIRING OF OLD SHED FABRICATION (SIZE 18 INCH X15 INCH) INSTALLATION AT CHP ELECTRICAL SWITCH YARD AKWMC UNDER KATRAS AREA
Trimming of trees around the 3.3KV OH Line erected area (Old and New Circuit) from 11KV Sub-Station to Potanga Sub-Station under Urimari OCP.
Construction of A Type two section School building G plus 2 4 Nos, Type-II Qtrs G plus 14 Nos Type-III Qtrs, G plus 1 01 No Type V Qtr canteen , Electrical Sub station , pump room , underground sump Boundary walls along with Gates & Guard room ... Networking sub station Equipment ...
Work of Dismantling Dragging and Transportation of 150 MVA, 220 132 KV Auto Transformer from Old PTPS Switchyard to 220132 KV Grid Sub Station Hatia II
Work of Stone Metal Spreading alongwith PCC and other associated work at One Part Section of 132KV switchyard at 220 132KV Grid Sub Station Hatia II
Maintenance and Renovation of 11kV/3.3kV Lakri Gate Substation, Charan Pahari Substation, KB Gate Substation, Bathan Tola Substation, Poorwa Colony Substation, Pachhima Colony Substation and Main Substation under Kuju Project, Kuju Area.
Installation of new earth pits for equipments installed at Central substation Basantpur under Hazaribagh Area
Repairing of two nos. of 11kV, 1250A, VCB, Make Andrew Yule, Sl. No. 3122 and Sl. No. 3123 and 3.3 kV, 400A, Make Andrew Yule, Sl. No. 4989 installed at 33/11-3.3kV, 22.5 MVA Old Sub-station of KDH OCP, NK Area
A Repairing and overhauling of 2 no. 3.3KV grade, different type and make of controlling switchgear installed at Main sub-station of Tarmi OCP. B Repairing and overhauling of 2 no. 11 KV grade, different type and make of controlling switchgear inst
Complete Repairing and Overhauling of 1 No. H.T. Switch 11 KV 400 Amps. ECE Make OCB Switch Local I.D. No. BCCL/NT-ST OCP/13 for Power Controlling of 300 KVA Transformer Main Switch at Huchuktand Sub-Station under NT-ST O.C.P.
Repairing of 01 (One) No. 200 Amps 440 Volt SD-15 Type Kilburn Make OCB Switch with Busbar Sl.No. 14018 Local ID-BCCL/JG/SW/OCB/550 V/33 at Durga Mandir Sub-Station of Amal.NT-ST-JN Colliery under Lodna Area.
1.Complete rewinding of 500 KVA/550V - Transformer, for feeding 550V power supply to UG/ surface equipment, No. 02 Sub-station, 2. 80 KVA, 550V/440V Transformer for domestic supply at Bokasthan colony, 3. 40 HP Tugger motor for tugger haulage operati
(1) SHIFTING OF 3.3 KV OVER HEAD LINE TOWARDS OLD SITE OF KANTAPAHRI SUB STATION(2) EXTENSION OF 3.3 KV POWER LINE FROM OCP VIEW POINT TO TC CHECK POST FOR INSTALLATION OF POWER T/F TO POWER CAMERA WEIGH BRIDGE AT AKWMC..
Complete Repairing 11 KV OCB 400 Amaps VCB Switch Electrotechnica Make for Controlling of 7.5 MVA Transformer at Marigodam Workshop Sub-Station Sl.No. 2312 Local Id. No. BCCL/JG/SW/VCB/11 KV/21 of Amal.NT-ST-JG Colliery under Lodna Area
Complete Repairing and Overhauling of 1200 Amps ECE Make 550 Volt O.C.B.Switch Sl.No.6664/36 at Durga Mandir Sub-Station for Lighting Line of Golden pahari worker Colony ( ID.No.BCCL/NT-SW/OCB/550V /64) of Amal NT-ST-JG Colliery under Lodna Area.
Complete Repairing and Safety Protection of H.T. Switch 11 KV 400 Amps Meditron Make VCB Switch Sl.No. 6354 for Power Controlling of 500 KVA Transformer main Secondary Switch at KT Sub -Station of NT-ST-JG OCP Local Id. No.NT/ST/JN-41.
(A) Dismantling, Erection, Diversion, Breakdown repairing of 6.6 KV Shovel Feeder No-(i) 6.6 KV Benidih feeder, 6.6 KV W/feeder power supply D/L Machine, drill shovel M/C and NOCP feeder Breaker KKC saiding Sub-station (B) Dismantling, Erection, Brea
Repairing and re-conditioning of 02 nos. (A) Repairing of 11KV, meditron make Sl. No 6284, 1250 Amps VCB (B) Repairing of 11KV Andrew Yule make Sl. No WNP 630 Amps VCB switch at main sub-station of SWG-GVP Ph-II OCP.
Repairing straightening welding clamping and re-storation of overhead for 11 KV Pipe pole and rail pole damaged in base portion at different location of incoming line of 06 No.sub-station to Golden sub-station and PCC Work to avoid hazards of Amal.NT
Maintenance, repairing and oil filtration of 3 MVA, 11KV/6.6KV or 3.3 KV, Yule make, Sl. No.-12121 and 1 MVA, 11KV/ 3.3 KV, Marson make, Sl. No.-24018 power transformer installed at sub-station of Tapin North OCP under Hazaribagh Area
Complete Repairing and Overhauling of 1 No. H.T. Switch 11 KV 400 Amps Bieeco Make OCB Switch for Controlling of 500 KVA Transformer Main Switch at Huchuktand Sub-Station of Amal.NT-ST-JG OCP under Lodna Area.(Local Id.No.BCCL/NT-ST/ OCB/22)
Partial Repairing/Overhauling and Safety Protection of 5 Nos. 200 Amps.440V.Kilburn Make O.C.B. Switch at Bagdigi Sub-Station Sl. No. (1) 14054 (2) 14025 (3) 14060 (4) 14059 (5) 14063 for Power Controlling lighting line of 5 No. Worker Colony Baba P