1,219 results • Best match
200 VA SINGLE PHASE, H CLASS INSULATION, 6KV, 750/415V CONTROL TRANSFORMER DULY FITTED WITH 2A, 1.2 KV FUSE LINK WITH FUSE BASE FOR PRIMARY APPROVED MAKE AND DULY FITTED WITH 2A, 500V FUSE LINK WITH F
Set of Spare Parts consist of (i)Current Transformer, Part No. PDSR25003 = 03 nos. (ii)Zener Diode, Part No. PDSR25004= 02 nos. (iii)Resistor 1K5/50W,Part No. PDSR25017=02 nos. of RRU of 25 KW Al
50 KVA cum 3 KVA Step Down Transformer, 3-Phase, 750V/415V/190V Dry Type, Confirming To RCF Spec No. EDTS-019, Rev. A, suitable for EOG Garib Rath Power Car. Firms Offer MAKE/BRAND:-BHASIN PACKARD
OIL PUMP WITH MOTOR TRANSFORMER, AS PER CLW SPECN. NO. CLW/ES/3/0106 ALT-F AND RDSO SPEC NO. RDSO/SPEC/E- 10/3/09 (MOTOR) WITH AMENDMENT NOS. 01, 02, 03, 04 & 05 OR LATEST.
DRY TYPE AIR COOLED 200VA, 750/415 VOLTS AC CONTROL TRANSFORMER, TYPE-II, H CLASS INSULATION 6KV, DULY FITTED WITH APPROVED MAKES 2 AMPS/1.2KV FUSE LINK WITH FUSE BASE FOR PRIMARY AND 2 AMPS/500 VOLT
50 KVA cum 3 KVA Step down Transformer, 3-Phase, 750V/415V/190V dry type, confirming to RCF Spec No. EDTS-019, Rev.A or latest. Suitable for EOG Garibrath AC Coaches. specn: RCF Spec.No. EDTS-019. Rev
50 kVA cum 3kVA dry type step down integrated transformer input voltage 750 Volt AC and dual output 415 Volt AC and 190 volt AC suitable for EOG AC Coaches of Garibrath express as per Specification No
Control transformer 100 VA,, single phase H-CLASS insulation and 6.0 KV 750/415 VOLTS AC, 50 HZ, High Voltage withstand capacity, Bill of material as per RDSO SPEC no.RDSO/PE/SPEC/AC/0184-2015(REV-1
100VA, 750/110V AC, SINGLE PHASE, TYPE-IV DRY TYPE AND AIR COOLED CONTROL TRANSFORMER AS PER RDSO SPEC: RDSO/PE/SPEC/AC/0203-2020 (Rev.0) FOR NON AC LHB COACHES. Make:- Bhasin / Vimal / Ramyaa. Accep
Contactor for 60 KVA Transformer suitable for switch board cabinet of LHB EOG AC Coaches, current rating 200 Amps, voltage rating 415 V AC, main pole 4 Nos. Aux Contact 1 NO + 1 NC, control voltage 16
CONTACTOR FOR 60 KVA TRANSFORMER RATED CURRENT - 95 AMP, RATED VOLTAGE - 690 VAC, MAIN POLE - 4, AUXILLARY CONTACT 1 NO + 1 NC, CONTROL VOLTAGE - 230 VOLT AC, +/- 30% (168 V AC-300 VAC) WITH ADD ON AU
SET OF BRACKETS FOR 60/9 KVA TRANSFORMER MOUNTING ON UNDERFRAME FOR LHB EOG COACHES CONSISTING OF THE FOLLOWING (1) LWSCWACEOG 71003 Alt.#a# COL I - 2 NOS. (2) LWSCWACEOG 71003 Alt.#a# COL II - 2 NOS
Estimate for Provding and Installtions of Vacuum Pumps, Construction of Transformer Shed, Board and Grills for Drainage Trench in Samlah Pharpur Lift Irrigation Scheme at RD 28000/L of A.S.H.C in Changer Area of Shri Anandpur Sahib
Online UPS ( 1 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA * Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 2.0 KVA 2.0 KVA Technology IGBT-PWM without inbuilt isolation transformer MOSFET-PWM with inbuilt isolation ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Providing HT/LT Line and Transformers in 17 Acre Development Scheme for Manshahia Nagar Scheme Sangrur.
Providing New Street Lighting, High Mast Lighting System with LED Fittings, Copper wiring Cover Shed, D E and Shifting of Existing HT LT Poles, Repair of Transformer, Rooftop Solar Power Plant in NGM Budhlada, M.C. Budhlada, District Mansa.
Low voltage HRC cylindrical low voltage fuse of capacity 2A 500V AC, 10 X 38 in size without fuse holder, used at output of control transformer (100VA) for K43 contactor coil at SBC of LHB AC & non-AC
MCB for 5KVA Transformer (primary) 16A, D Curve, 415 V AC, 3 pole, breaking capacity 10KA. Suitable for LHB type AC Coaches. As per Sr. No. 32 and place of installation S1F107 of RDSO letter no. EL/7.
Control transformer 100VA, single phase "H" class insulation 6kV, 750/415 Volt, As per RDSO spec no- RDSO/PE/SPEC/AC/0184-2015(REV-1) and modification sheet No. RDSO/PE/MS/AC/0051-2011 (Rev. 2) Ame
200 VA, 750 V / 415 V, AC, Single phase, dry type and air cooled control transformer with LT & HT fuses as per RDSO specification No. RDSO / PER / SPEC / AC / 0203 - 2020 (Rev.0), Type II and RDSO dra
250 VA, 750/415 V AC, 3 PHASE, 3 WIRE STAR / STAR VOLTAGE MEASURING TRANSFORMER FOR LHB AC POWER CAR, TYPE-VIII, AS PER RDSO SPECIFICATION NO: RDSO/PE/SPEC/AC/ 0203-2020 (REV-0). Make: BHASIN PACKARD,
500 VA 750V/415 V AC 1 phase Dry type air cooled control transformer as per RDSO Specification No RDSO/PE/Spec/AC/0203-2020 (Rev-0) Type 1, (Ltr.No.EL/7.1.108/SBC/Main file dt.16.04.2021) letter enclo
50 KVA cum 3KVA dry type step down integrated transformer input voltage 750 volt AC and dual output 415 volt AC and 190 volt AC suitable for EOG AC Coaches of Garib Rath express as per specification N
DRT TYPE AND AIR COOLED 200 VA, 750/415 VOLTS AC CONTROL TRANSFORMER H CLASS INSULATION 6KV, DULY FITTED WITH APPROVED MAKES 4 AMPS/1.2KV FUSE LINK WITH FUSE BASE FOR PRIMARY AND 2 AMPS/500 VILT FUSE
415V/190V,3 PHASE,DRY TYPE NATURAL AIR COOLED POWER DISTRIBUTION 5 KVA TRANSFORMER WITHOUT FILTER .CONFORMING TO ICF SPEC NO.ICF/ELEC/906 REV-1,OR LATEST TYPE-III AND ICF DRG.NO.ICF/SK3-7-1-070 OR LAT
set of Pressure gauge for Transformer oil pump make Flowwell Model 1575 of 3-Phase locomotive. 1 Set consists of 2 gauges. The gauge should have Steel body, Glycerin filled up, 1/4" BSP thread, 0-7 ba
100VA step down transformer 750/110 V AC H-Class insulation suitable for LHB Non AC coaches, confirming to RCF spec. No. EDTS-355 Rev.1 or latest AMNDT.2. MAKE/BRAND- BHASIN PACKARD as per Drg.No. RCF
Set of M-16 Hex. Head screw complete for fixing arrangement of 9/15 KVA Transformer in LHB Coaches. Set consist of the following 4 items; (1). Hex.Hd.Screw IS:1364(Part-2)/ISO-4017 - M16 x 50 - Grad
Supply of K44 contactor for 60 KVA transformer rated current: 200 A, rated voltage: 690V AC, Main pole: 4, Aux contact: 01NO+1NC, Control voltage: 230V AC (168 V AC-300 V AC means 230V AC +/-30%) with
PROCUREMENT OF 220KV AT2 type Transformer CRP panels 220KV AB2 Bus couple panels CRpanels 66KV CT2RS type Transformer Secondary side CR panels
Rubber Armouring, Loctite, Main Board, Regulator 7812, Transformer
Online UPS Online UPS ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 1.0 KVA As per GeM Catalogue. Technology MOSFET-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt ... isolation transformer , ... isolation transformer , ... isolation transformer Input ...
Replacement of existing false ceiling (wooden and PVC) with G.I. Metal ceiling with the provision of anti-glare lights in main control room, AEE offices, LT room, Battery rooms and Auxiliary transformer rooms at Ganguwal and Kotla Power Houses
SPL REPAIR/ REPLACEMENT OF CEILING FANS AND GEYSERS AGAINST BER, PROVN OF GEYSER, EXHAUST FAN, CEILING FAN, SOLAR WATER HEATER AND ISOLATION TRANSFORMER CAPACITY 10 KVA UNDER AGE E/M -V OF GE (N) BATHINDA AT BATHINDA MIL STN
Pro Ext Elec Works Rooftop Solar Power Plant Campus Security Lighitng High Mast LED Lighting 11 KV Sub Station Work Silent Type DG Set Shifting of Existing Transformer and VCB Etc For construction of Silos At Punjab Agro Ex
Neutral Current Transformer (NCT) , 25 KV Class Ratio A along with 10 Nos. Terminal Connectors for Each NCT confirming to RDSO specification No.-ETI/PSI/90(06/95) with A & C Slip 1 to 8 ( Apr 09) or L
Metering transformer capacity 300 VA, 750V/415V3 phase/110V AC, 3 phase suitable for LHB Power cars. Similar to M/s Bhasin Packard part no. RG/36/82/7 TP as per RDSO specification no. EDTS-103, Rev D.
CONTACTOR FOR 60 KVA TRANSFORMER RATED CURRENT -95 AMP, RATED VOLTAGE- 690 V AC, MAIN POLE - 4, AUXILLARY CONTACT 1 NO + 1 NC, CONTROL VOLTAGE - 230 VOLT AC (168 V AC-300 V AC MEANS 230 VOLT AC +/- 30
200 VA ,750/415 VAC , 1 phase dry type and air cooled control transformer for SBC of power car and MSSBC of HOG AC Coaches, insulation class H , as per RDSO specification RDSO/PE/SPEC/TL/D/0203-2020
CABLE ASSY COMP WITH SOCKET 3 POLE, MAIN SWITCH ROTORY, TRANSFORMER 20 AMP, TRANSFORMER 10 AMP, DECARBONISING JOINTS SET FOR ENGINE, BRUSH HOLDER ASSY
ONLINE UPS REPAIR TRANSFORMER, CONECTOR, PCB, RELAY, SERVICE CHARGE
Rubber Armouring, Loctite 1, Main Board, Regulator 7812, Transformer
UV CABINET, SOLONIED VALVE, TRANSFORMER, SCALER, AEROSCOPE SET COMPLETE
Ac Capacitor, Drive Card, Charger Card, Bridge Rectifier, Transformer
SYRINGE INFUSION PUMP, SYRINGE NEEDLE DESTROYER, TRANSFORMER, CAPACITOR, THERMOSTAT
Construction of 1 No. 400 KV ICT bay , 1 No. 220 KV ICT bay , Design , Engineering , Manufacture , Supply , Transportation , Erection , Testing and Commissioning of 1 No. 500 MVA 400/220/33 KV Auto Transformer at 400 KV Nakodar , Dismantlement Work
Voltage Measuring Transformer 750/415 V, 3 Phase, 100 VA, 3 Wire, Delta/Delta, 50 Hz, Class -1.0 with 2 A Fuse in Primary as per RDSO Specification No: RDSO/PE/SPEC/TL/0195-2019 (Rev.-0) or Latest Sui
500 VA 750V/415 V, AC 1 phase Dry type air cooled control transformer as per RDSO Specification No. RDSO/PE/Spec/AC/0203-2020 (Rev-0) conforming to item No. 4 of Bill of material of RDSO Spec. No. RDS