Loading…
Loading…
688 results • Best match
Design, Manufacturing ,Testing and Supply of 6 Sets of Pantograph Isolator with structure for the use at 220kV Substation, Brahmapuram in connection with replacement of 220kV Ambalamughal -Brahmapuram overhead transmission line passing through BPCL
Stringing of 1 kV Aerial bunched cable of size 3 x 70 sqmm with bare insulated Messenger through existing poles 2562 meter and allied works.
Strengthening existing LT line using A pole, shifting Pullikkadavu transformer and rearranging the existing pulipandy transformer DP for drawing HT ABC for interlinking the 11kV line
As per Tender
Erection of various equipments such as CT,PT,CB Isolator etc, stringing and jumpering of bus, earthing the equipments of 220 KV switchyard of Thottitar HEP
ERRECTING 160 KVA TRANSFORMER AFTER CONSTRUCTING 1.7 KM OF 11KV LINE, STRINGING 0.75 KM 3PHASE AND 2.15 KM SINGLE PHASE LINE AND ALL OTHER ACCOMPANYING WORK
Bay modifications at 400kV Substation Madakkathara for routing 220kV lines from PGCIL HVDC Station - Providing foundation and erection and dismantling of equipments, bus stringing works etc
Construction of 1 km 11 KV OH line , 0.1 km HT ABC,installing 1 no 100 KVA Tfr and also reconductoring of LT line under Ele.Sn.,Kurichy
Stringing of 1.1 kV Aerial bunched cable of size 25 sqmm with bare insulated Messenger through existing poles 13502m Erection and commissioning of street light metering 11Set
Erection and commissioning of street light metering 12Set and Stringing of 1.1 kV Aerial bunched cable of size 25 sqmm with bare insulated Messenger through existing poles 9110m
Construction of foundation of yard structures and equipments, erection of yard structures and equipments, dismantling of 66kV bus, , stringing earth wire, providing interconnections, Providing earth mat, equipment earthing
Construction of new HT line using 99 sqmm Covered Conductor after the erection of 9m PSC Pole in position for HT interlinking bwtween Silent Nagar to Cheruval under Electrical Section Parappukkara
Carrying out Dyuthi Works of PMU in sections of ESD Panamaram which includes erection of DTR, Constructing overhead HT and LT Lines, Reconductoring with MVCC and HT ABC, insertion of poles, providing stays and earth and all other accompanying works
Providing temporary alternate 66KV supply to Kattanam Substation- Stringing 260Mtr 11kV line using covered conductor for interconnecting the UG and OH portion of 11kV Thodiyoor feeder at Chakkuvally Junction
1.Construction of 11kV line using ACSR RACCOON using PSC pole - 1.3 kilometer 2.Construction of 11kV line using ACSR RACCOON using A pole - 0.7 kilometer 3.HT LINE Reconductoring with ACSR RACCOON - 0.8 kilometer
construction of one number feeder bay at 110kV Substation Sasthamcotta and stringing of three line wolf through the existing 1STKM feeder(2 span) for providing LILO arrangement for 1EPKD-T-ST feeder
Supplying and Drawing of LT ABC at Electrical Section, Sakthikulangara under Electrical Sub Division, Sakthikulangara 5.6 Km of size 70 sq.mm Aerial Bunched Cable through the existing LT line on Turnkey basis at
1. Construction of 11kV line using ACSR RACCOON using PSC pole- 1km 2.Construction of 11kV line using ACSR RACCOON using A pole-1.5km 3.Providing HT LINE AB SWITCH including erection of structure- 2 No.
The work mainly involves Erection of Equipment and yard structures and assembling of columns and beams, Earthing of equipment and structures, Stringing of Busbar and earthwire and Fabrication of structures for erecting equipments .
1.Construction of 11kV line using ACSR RACCOON using PSC pole -0.5 KM 2.Construction of 11kV line using ACSR RACCOON using A pole- 1km 3.Providing HT LINE AB SWITCH including erection of structure -2 No.
1.Construction of 11kV line using ACSR RACCOON using PSC pole -05. km, 2.Providing HT LINE AB SWITCH including erection of structure -2km. , 3.Construction of 11kV line using ACSR RACCOON using A pole -1.6 km
Stringing, Testing and commissioning of 37.63 kms of LT ABC of size 3x95 1x70 1x16 sqmm on 8 meter and above supports on contract basis at various locations under Ele Circle Tirur, Malappuram District
Stringing of 11 kV Aerial bunched cable 6500mts Fitting and erecting one HT DP using A type pole 2 Nos Renewal of HT PSC pole with A pole and Fitting and errecting DP 2Nos
Dismantling of existing OPGW and re stringing same in new tower.Insertion of new D60 and 4.5m tower nearer to the existing and dismantling existing D3 and 4.5M tower. Dismantling existing 1KHMT and 1CMMT line and restringiing.
Supply of hardware fittings and clamps, Dismantling of 110kV Single bus and stringing of the bus with double kundah Conductor, Dismantling of 110kV Bus isolators and installation of new bus isolators after doing necessary civil works
Supplying and Drawing of LT ABC at Electrical Section, Thangaseery under Electrical Sub Division, Sakthikulangara 6.05 Km of size 70 sqmm Aerial Bunched Cable through the existing LT line on Turnkey basis at Manjavil, Cherukulam and Punathala
The work includes dismantling of LT 1 PH, 3 PH OH lines and stringing with 3 PH LT ABC. Also the work includes insertion of poles Providing coil earth renewal of poles and renewal Providing LT Stay
Drawing 600 mtrs HT ABC using HT pole from Tharatta to Nilami and installing 160KVA Transformer including reconductoring the existing old and aged LT line with LT ABC at Electrical Section Kachani CW-4691-202526-47 under Electrical Div
Supply and stringing of 900m 33Kv Covered Conductor, 2400m11kV AB Cable, 2900m LT AB Cable including shifting of all existing lines and Poles and Erection of all types of Poles and Lattices on Turnkey Basis under Electrical Section, Puthur
Earth work in excavation of all kind of soil PCC RCC Centering shuttering Survey of the proposed cable route cable laying preparation of final cable route HDD Laying of 33kV XLPE UG cable DP an isolator erection stringing earthing mate
This estimate is prepared for the voltage improvement at Kavilummaram-Kacherimukku area, under 160 KVA Kavilummaram DTR station and 11 KV Kacherimukku DTR station. The work includes dismantling of LT 1 PH OH lines and stringing with 3 PH LT ABC.etc
Erecting Ht A pole, HTpole, HT DP ,Dismantling damagd HT pole, RCC pole, HT PSC wo damage,A pole wo dmge,11 kV line, AB switch,Dismantling transformer station,Providing Ht stay,Stringing 11kV lines,Erection of 100 kVA transformer, Fitting AB switch
Electrical works related to Installation of 200MVA Tfr at 220KV SS BPM
Stringing 11 KV OH 1130 Mtr Erecting 100KVA TFR 1Nos Providing AB SWITCH 1 Nos Erecting HT 33 nos Providing HT Stay 41 nos Providing HT Strut 1nos Providing HT FLY STAY 1 NOS Dismanling LT pole good 20nos Dismanling LT pole Damage 7 nos
1.Erection of 100 kVA DTR ON DP using A-POLE at line end -1 No. 2.Construction of 11kV line using ACSR RACCOON using PSC pole -0.4km 3.Construction of 11kV line using ACSR RACCOON using A pole -0.9 KM 4.Providing HT LINE AB SWITCH -1No.
1.Construction of 11kV line using ACSR RACCOON using A pole- 1.5 km, 2.providing HT LINE AB SWITCH-1 No.3.Erection of 100 kVA DTR ON DP -1 No., 4.Construction of 11kV line using ACSR RACCOON using PSC pole-0.5kM,5.Dismantling 11kV line complete-2.8KM
Supervision of Erection of Surge Monitors, Supervision of Erection of 420kV 10 kA Class2 Transmission line Lightning arresters, 420kV 10 kA Class2 Transmission line Lightning arresters, Surge Monitors as per Technical Specifications MSE Exemption for ... Class2 Transmission line Lightning ...
Custom Bid for Services - Preventive Maintenance Yearly of 11KV HT Over Head Line of approx 700 M for one year Qty 1Set, Custom Bid for Services - Breakdown service Ensure serviceability of 11KV HT line on Emergency Breakdown for one year Qty 1 Set, Custom Bid for Services - Preventive maintenance of HT panels ie 11 KV HT indoor and outdoor breaker panels for one year Qty 1Set, Custom Bid for Services - Breakdown service Ensure serviceability of HT panels on Emergency Breakdown for one year Qty 1Set, Custom Bid for Services - Preventive Maintenance Yearly of LT APFC and Main Lighting panels for one year Qty 1Set, Custom Bid for Services - Breakdown service Ensure serviceability of substation on emergency breakdown for one year Qty 1Set, Custom Bid for Services - Preventive Maintenance Yearly twice of 110by440 KV 500KVA distribution transformer for one year Qty 2 Sets, Custom Bid for Services - Preventive Maintenance Yearly of Power Control Circuit and Power Distribution panels for one year Qty 1Set, Custom Bid for Services - Insulation resistance checks and reporting the condition of all the feeder cables from LT panel to the PCC panels Qty 17 Nos