SPECIAL REPAIR TO DG SETS FOR WATER SUPPLY INSTALLATIONS AGAINST BER AND ALLIED WORKS AT SECTOR B AND SPECIAL REPAIR TO CHEMICAL DOSING SYSTEM FOR SYL FILTRATION PLANT UNDER GE U AMBALA CANTT
Material & labour for sand cushioning with clean dry sand to cables with layer of sand 8 cm before laying of cable and 15 cm thick after laying of cable complete all as specified and directed. Note : For payment purpose punned thickness of 18 cm shall be measured against spread thickness of 23 cm as mentioned in para 19.75 of SSR part-I.
REPAIR/MAINT TO DECORATIVE LIGHT, GARDEN LIGHT AND MISC WORK AT HELIPAD AREA DGRE RDC MANALI UNDER AGE (I) RnD MANALI.
S&F in repair FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable , 1100 Volts , conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting including 20 mm PVC conduit in trenches with excavation,return filling and removal of surplus soil not exceeding 50m distance for laying of cable complete including taking down old unserviceable cable complete all as specified and directed by Engineer in Charge.
PROVN OF STP FOR AIRFIELD SINGLE OFFRS ACCN COMPLEX AT MCTE UNDER GE MCTE MHOW
Supply ,laying ,testing cable xlpe insulate of size 50 sqmm 3.5 core, complete all as specified and directed.
Transgrid down stream works at 110kV substation TERLS Repositioning of 20 MVA, 110/11 kV Transformer Unit 2 to Enable Double Bus Upgrade at 110 kV Substation, TERLS
Giving three phase connection to the filter unit from the supply mains using cable including fitting three numbers of fuse units near the filter unit and laying the cable from control room to filter unit and trial run of filter unit after giving connection etc. complete as per the direction of dept. Officers.
SPECIAL REPAIR TO BLDG NO P405 AND P157 OF 120 ENGR REGT AT KALIMPONG MIL STN UNDER GE 867 EWS
M&L for Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches etc. complete all as specified and as directed.
ADDITION, ALTERATION TO THE EXISTING SHARQAT AUDITORIUM TO INCL ADDITIONAL TOILETS, SEATING AND REPAIR TO EXISTING PROJECTOR AT THE MARATHA LIRC BELAGAVI UNDER GE BELGAUM
M&L for Dry & clean tibba river sand cushioning in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable, levelled and punned down to a depth of 100mm above the top of the upper-most cable, for cable protection in trenches, complete all as specified and as directed. Note: The punned down thickness shall be measured for payment.