Loading…
Loading…
689 results • Best match
as per described in tender docs
High-performance enzymatic cleaner for surgical, medical, and dental instruments- 1-liter.• Leaves no residue after wash, Stable formulation with near Neutral pH. • Should be usable for manual, ultra sonic and automatic cleaning systems • Properties should have been tested by methods prescribed by NACE TM0374:2007 & NACE TM0169/ ASTM G31: 2012. It uses the Advanced Film Enhanced Protective Polymer (FPPO) Technology that gives it Scale Prevention, Rust Inhibition & Shine Retention Properties. Fast acting within 5-10 minutes, Bottle 1 Ltr. Heavy Contamination: 10ml per Liter, Moderate Contamination: 7.5ml per Liter, Light Contamination: 5ml Per Liter. Sodium Xylenesulphonate-7wt, Disodium tetraborate decahydrate & Ethylene glycol -5wt, .beta.-Alanine, N-(2-carboxyethyl)-N-(2-wt.
Operation of PWS/WLS piped water supply schemes (Quality affected/NQ affected) by deploying pump operators and payment of electricity charges and II. Comprehensive maintenance of PWS/WLS water supply schemes (Quality affected/NQ affected) i/c the ... filter media and ...
13.79.7 Providing all labours, materials for fixing perforrated mosquitto jali on ventilator shaft. 1 Job Each Rs.1,000.00 Rs.1,000.00
SUPPLY OF WIRELESS INTERCOM SYSTEM
The power supply of all the LRUs shall comply with MIL-STD-704D requirements & should have built-in protection against power supply malfunctions.
(Re-Tender) Repair, electrical work, painting and drainage system work of the administrative building and hostel located in BAMETI campus.
20 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubula sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
SUPPLY OF AERIAL FIRE FIGHTING EQUIPMENT
Description Aerial Fire Fighting Equipment is an add on system to helicopter for emergency fire fighting operations. Fire fighting equipment shall be operated in fresh water, sea water and chlorinated pools. The equipment shall be designed to perform fire fighting operations by lifting a collapsible fire fighting bucket suspended to the cargo hook of the helicopter by means of lifting and dumping water or fire retardant chemicals. Fire fighting bucket shall be collapsible with multiple drop pattern valve. The multiple drop capability shall allow an operator to split the bucket load over several locations. The valve shall be opened & closed partially or fully and there shall not be any limit to the number of times it can be opened or closed. The fire fighting equipment shall have the option for fitment of Foam Injection System (FIS).FIS shall be attached to bucket such that foam chemical shall be clear of helicopter.FIS shall deliver a timed volume of foam to the water within the bucket. Types of fire (viz.class A,B,C,D,F & fire caused by electrical equipment etc.) that can be extinguished using foam,foam and water combination shall be specified.Vendor shall specify the following • Different type of chemicals apart from water & foam. • Minimum flying height over fire zone to protect bucket, sling system & its components. • Temperature limit for components of AFFE which are suspended to the cargo hook viz Bucket,cargo sling system,compressor,pneumatic lines, electrical cables etc. over the fire zone. • Max flying speed that AFFE is designed for( with full load & no load in bucket). Fire Fighting bucket shall provide bucket filling through rapid dip filling method and filling with the Shallow Fill Pump(SFP). The pump shall be fitted internally (desirable) within the bucket. Aerial fire fighting operation shall be performed either by cockpit or cabin crew by means of control pendent one each provided in cockpit & cabin. Aerial Fire Fighting Equipment shall be equipped with Load Indication System(LIS). The same shall provide continuous monitoring and display of the water load in the cockpit & cabin pendants. There shall be a provision on LIS to interface LIS with helicopter display system. Aerial fire fighting operation shall be performed either cabin door in open or closed condition.During cabin door open condition, operation of AFFE shall be performed by cabin crew by means of control pendent provided in cabin. During cabin door closed condition, operation of AFFE shall be performed by cockpit crew by means of control pendent provided in cockpit. UH-M will be equipped with Electro Optical (EO) system. The EO video will be available on MFDs. In cabin door closed condition, EO video will be used by the pilot/co-pilot to view / locate the fire zone to dispense water from AFFE. Permanent looming/patch cord shall be provided on helicopter for AFFE operational requirements with cabin door closed condition. Necessary electrical harness and pneumatic lines connecting power pack and bucket respectively shall be provided by the vendor. Electrical power for operation of the system shall be independent of helicopter power. Fire fighting equipment shall be easily jettisonable in case of emergency situations. The bucket shall be connected to the Power Pack by a breakaway plug. The purpose of the plug is to offer a clean “breakaway” if the bucket needs to be jettisoned from the aircraft in an emergency. The bucket will be suspended from cargo hook and the power pack shall be strapped/mounted on the floor of the helicopter. Characteristics • Water filling time: Max 7 sec. • Water discharge time: Max 7 sec in continuous discharge method. • Flight speed with aerial Fire Fighting equipment: Upto 55 Kt
1. TOURIST DEVELOPMENT OF VISHWAMITRA PLACE, VISAUL, LOCATED IN HARLAKHI BLOCK UNDER MADHUBANI DISTRICT.
69 9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. 0