Online UPS ( PAC Only ) Online UPS ( 3 ) ( Under PAC ) Make unitechpower Model unilineonlineuw5 Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 20.0 KVA 20.0 KVA Technology IGBT-PWM with inbuilt isolation transformer MOSFET-PWM with inbuilt isolation transformer, IGBT- PWM with inbuilt isolation transformer, IGBT-PWM without inbuilt isolation transformer Input Power Three phase 300 V - 450V sinewave, 50Hz single phase 160V - 260V sinewave, 50Hz, Three phase 300 V - 450V sinewave, 50Hz Output power 3 Phase 400V +/-1% with alternative user setable setting of 380V +/-1% 50 Hz Single phase 230V +/-1% sinewave 50 Hz, 3 Phase 400V +/-1% with alternative user setable setting of 380V 1/4 +/-1% 50 Hz Backup time (Minutes) 120 15, 30, 60, 90, 120, 180, 240 Minimum VAH (VAH) 96000 400-640000 Warranty for UPS (Years) 1 1, 2, 3, 4, 5 Movable trolly for Batteries Without With, Without, Without trollery but with rack Warranty for battery 1 1, 2 Degree of Protection IP21 IP21, IP20 Cabling 5 meters for input and out put With With, Without Paralleling kit for synchronising With With, Without Installation and Commissioning Yes * CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 * Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I, II&III) * FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 * Voltage Regulation from no load to full load (%) </= 3% * 20% Overload limit for minimum 10 minutes Yes * Overall Efficiency (%) >/=90% * Total Harmonic Distortion(THD) (%) Maximum 3% * 50% Overload limit for minimum 1 minutes Yes * PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes * Protection of Over voltage, Short Circuit & over load at UPS output terminal Yes * METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage, Output AC Volt age, Current, Frequency, Yes * 2/4 Battery Voltage and Current Indicators for mains presence, Battery charging and discharging, Output Over Load, Low Battery Voltage Yes * REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * Type Test Certificate No. - * Type Test Certificate date - * Name of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 3/4 1 Mukesh Shukla 492001, O/o Executive Engineer, (E&M) Public Works Department Sirpur Bhawan Parisar, Raipur. (C.G.) 3 15
Loading…