diesel generators- DG Sets Average Turn Over of Last 3 Years 10000 Lakh (s) Experience with Gov. Required 2 Year (s) Diesel Generators- DG Sets ( 18 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 15 15 No of Phase - threephase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No, if applicable - - Type of Engine cooling Air Cooled aircooled Type of governer Mechanical mechanical Class of governer A1 a1 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - 1/5 Rated RPM of Engine (RPM) - 1500 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 15 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 89.6 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF amf IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6, 1.8, 2, 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 30 - Noise level at 1 meter (dB) 72.5 - BATTERY Battery Type & Specification Normal lead acid to IS: 7372 for motor vehicles - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/5 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986, in respect of noise and emission norms, as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning With Installation withinstallation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Jayant Kumar Tyagi 246429, 8th Bn ITBP Gauchar 4 15 2 Sher Singh 248146, 1st bn suneel joshimath, chamoli (uttrakhand) 1 15 3 Chhering Tashi Bodh 175101, 2nd BN I.T.B.POLICE KULLU 6 15 4 Harish Chandra Upreti 248146, 23rd BN ITBP Camp Seemadwar 4 15 5 Sukhraj Singh Sidhu 171001, 43rd BN ITBP Shalabag, sarahan 1 15 3/5 6 Anil Kumar Jha 134111, 50th BN itbp Ramgarh 2 15 EMD Required No ePBG Advisory Bank State Bank of India ePBG Percentage(%) 5.00 Duration of ePBG required (Months). 26
Loading…