Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 0.5/84, 0.5/168, 0.5/400, 0.65/168, 0.65/400, 0.65 108, 0.8/168, 0.8/400, 0. 8/216, 1.0/168, 1.0/400, 1.0/216, 1.0/800, 1.5/80 0, 1.5/600, 2.0/800, 2.0/1 600 Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single phase sinewave 230v AC, 50Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 70% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year, 2 Years, 5 Years Installation and commissioning No - 1/4 instructions CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes, No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND Damp heat Test at 45 Yes - 2/4 CERTIFICATIONS degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 41016861 19.10.2015 - Name Of Lab BIS - Address of Lab BIS, Manak Bhawan, 9, Bahadur Shah Jafar Marg, New Delhi-110022 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Parthiban Arumugam 744102, Communication Centre HQANC C/o Navy Office Port Blair- 744102 13 45 EMD Required No ePBG Required No
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 13 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/216 0.5/84, 0.5/168, 0.5/400, 0.65/168, 0.65/400, 0.65 108, 0.8/168, 0.8/400, 0. 8/216, 1.0/168, 1.0/400, 1.0/216, 1.0/800, 1.5/80 0, 1.5/600, 2.0/800, 2.0/1 600 Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single phase sinewave 230v AC, 50Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 70% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 1 Year 1 Year, 2 Years, 5 Years Installation and commissioning No - 1/4 instructions CONSTRUCTIONAL Type of enclosure Mild steel - AC out put for printer (not through inverter) No Yes, No Inverter out put socket AC out put for printer (not through inverter) Not applicable 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND Damp heat Test at 45 Yes - 2/4 CERTIFICATIONS degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date 41016861 19.10.2015 - Name Of Lab BIS - Address of Lab BIS, Manak Bhawan, 9, Bahadur Shah Jafar Marg, New Delhi-110022 - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Parthiban Arumugam 744102, Communication Centre HQANC C/o Navy Office Port Blair- 744102 13 45 EMD Required No ePBG Required No
7 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.