Loading…
Loading…
3,611 results • Best match
Construction of 0.45 Km 132 kV Cable section from Terminal Tower of overhead section of line between 132 kV GSS Bagara to Railway TSS at Marwar Bagara using 400 sq. mm 132 kV XLPE Cable system (3 phase PLUS 1 spare) (Deposit work of Railways)
85916 E8 Repair or Maint of Fire Alarm,Voltage Stabilizers,Cranes and other EM Assests and Repair or Maint of old Unserviciable LT Panel,Cable joints and Underground LT cable in Technical Area At Air Force Station Jodhpur
PROVN OF 50 X DESERT COOLER FOR ORs IN OTM ACCN FOR 103 AD REGT AT PARADE GROUND AND SPL REPAIRS/ REPLACEMENT OF OLD LT DISTRIBUTION FEEDER AND CONNECTED UG LT CABLE AT 39 FAD BHARATPUR MIL STN
As per Technical Specification
Supply and Drawing of insulated Rabbit conductor on existing poles in main mandi yard Bijaynagar
CC Road Construction Work From Kailash Master House to Badansingh Conductor House Ward No. 13
090400029 CABLE BLASTING COPPER PVC INSU COPPER CONDUCTOR CABLE SUITABL FOR BLASTING CONFIRMING TO R
REPAIR/MAINT OF LT PANEL, UG CABLES, LT OVERHEAD CONDUCTOR AT RALAWAS UNDER GE BANAR
FIABLE Cables 3 Core 2.5 sq. mm PVC Copper Circular Sheathed Cable with Rigid Conductor
LT XLPE INSULATED ACSR RABBIT CONDUCTOR SUITABLE FOR WORKING VOLTAGE UPTO AND INCLUDING 1100 VOLTS
REGISTER, CANVAS CLOTH, FILE COVER, SAND BAG, ELECTRIC WIRE 1.5MM
High Mast, avaition light, armoured cable, earthing, LED Flood Light, Lugs, Astronomical timer, Timer Panel
2.5 Metre long Power cable harness drawn in halogen free polyamide fire retardant anti rodent suitable conduit as per IEC-61386-22 with suitable end fitting having IP-65 degree of protection conformin
PVC Copper Cable Single Core and Multi Core Circular Sheathed Cable with Rigid Conductor (V2) as per IS 694 (Q2) MSE Exemption for Years Of Experience and Turnover Yes | Complete Startup Exemption for Years Of Experience and Turnover Yes | Complete Document required from seller Experience Criteria, Past Performance, Bidder Turnover *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? No Past Performance 10 % Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Bid Number : GEM/2025/B/6364637 Dated : 24-06-2025 Bid Document 1/6 Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No Splitting
A set consist of following items : (A) Frame for Conductor Berth as per drg. no. CC-61386. (Qty. 01 nos.) (B) Bracket Complete for Fixing Conductor Berth as per drg. no. CC-14406. (Qty. 02 nos.)
PVC Flexible cable multistrand wire copper conductors cross section 25 sq.mm as per specn. IS 694/1990 latest in red and Black Colour of make Havells, Finolex, Polycab Firms Offered Make- RETCOCAB
10 sq.mm. Electron beam irradiated thin walled flexible elastomeric cable with copper conductors for working voltage up to 750 volts as per RDSO specification No. ELRS/SPEC/ELC/0019 , Rev.'3' , Colour
1.5 Sq mm Electron Beam irradiated thin walled flexible Elastomeric cable with copper conductors for working voltage above 750 Volts up to 1.8KV/ 3.0 KV Confirming to RDSO's Specification No. ELRS/ SP
XLPE INSULATED ACSR RABBIT CONDUCTOR SUITABLE FOR WORKING VOLTAGE UPTO AND INCLUDING 1100 VOLTS against tn-1092
Online UPS 2KVA, Colour Laser Jet Printer, Black and White Laser Jet Printer, UPS 650 KVA, Multifunction Device, 2.5mm Copper Wire, 1.5mm Copper Wire, Power Cord 6A, UPS Battery 12V 7.2AH
ACSR (Aluminium Conductor Steel Reinforced) Code size 'FERRT' stranding wire diameter 'AL' 6/3 mm, s
REPAIR/MAINTENANCE AND UPGRADATION OF STREET/SECURITY LIGHT FEEDER FROM CP-I TO ASC UNIT AND OTHER AREA INCI REPLACEMENT OF STREET/SECURITY LIGHT FITTINGS , LT CABLE , POLE BOX ETC AT ARMY AREA JODHPUR UNDER GE (ARMY) UTILITY JODHPUR
REPAIR/MAINT OF LT CABLE AND ALLIED WORKS AT DOMESTIC AREA IN AREA-I AND REPAIR/MAINT OF DG SETS, CONTROL CABLES,LT CABLES AND OTHER CONNECTED WORKS AT DOMESTIC AREA, TECHNICAL AND 03 AFRU UNDER GE (AF) JAISALMER
POWER CABLE AND CONTROL CABLES
Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor re
Miniature Circuit Breakers Distribution Boards as per IS 13032 (Q3), PVC Copper Cable Single Core and Multi Core Circular Sheathed Cable with Rigid Conductor (V2) as per IS 694 (Q2) (3 (3 ))
UMBRELLA, WHITE CLOTH, DUMMY RP, EXOSKELETON, COPPER WIRE, TATA SKY, PRINTING FOR BLINDS
LT XLPE INSULATED AERIAL BUNCHED CABLES WITH BARE MESSENGER WIRE FOR LT OVER HEAD LINES SUITABLE FOR WORKING VOLTAGE UPTO AND INCLUDING 1100V For Sizes 3C_25_25 Sqmm CONFORMING TO IS_14255_1995 AMENDED UPTO DATE UNDER SPECIFICATION NO JdVVNL
As per tender Specification
Modification work of 132kV S/C Line between 220kV GSS Bagru and 132kV GSS Bagru from Loc No.13 to 16 with 500 sq. mm. 132kV XLPE Cable System with termination on 220kV and 132kV Narrow Base Towers (Deposit work of M/s Manipal University, Jaipur)
3 core bright Annealed Bare multistrand 1.5 sq mm copper conductor heavy duty flexible Cable (Q3)
EARHING AND LIGHTNING CONDUCTOR IN MD ACCN/OTM ACCN UNDER THE JURISDICTION OF GE (A) JAISALMER
REPAIR/ MAINT OF SOLAR WATER HEATER SYSTEM LIGHTENING CONDUCTOR AND EARTHING SYSTEM AT NIWARU MIL STN
SUPPLY OF PVC WIRE 2.5 SQ.MM., 4.0 SQ.MM., 6.0 SQ.MM. TC ALUMINIUM CONDUCTOR (YEAR 2022-23)
Purchase of Fiber Glass Operating Rod with Earthing conductor lead and with and without Tree Pruner
REPAIR AND MAINT OF LIGHTNING CONDUCTOR AND EARTHING AT ZONE -II AREA UNDER GE (A) JAISALMER
20 pair Switch board cable of 0.5mm dia conductor as per TEC Spc: GR/WIR-06
35 sq mm Cross linked polyethylene and XLPE insulated PVC outer sheathed cable with aluminium conductor.
Purchase of Fibre Glass Operating Rod with Earthing conductor lead and with and without Tree Pruner
SUPPLY OF FIBRE GLASS OPERATING ROD WITH EARTHING CONDUCTOR LEAD AND WITH AND WITHOUT TREE PRUNER
LT XLPE INSULATED ACSR RABBIT CONDUCTOR SUITABLE FOR WORKING VOLTAGE UPTO AND INCLUDING 1100 VOLTS
Supply of spare ACSR Zebra conductor for use in 220 KV Switchyard at KSTPS, Kota.
ISI MARKED FOUR CORE LT XLPE INSULATED AND PVC SHEATHED ARMOURED CABLE Of SIZE 4CX185 SQ.MM
10 Sq.mm Electron Beam irradiated thin walled flexible elastomeric cable with Copper Conductors for working voltage upto 750 Volts as per RDSO specification No. ELRS/ SPEC/ELC/0019 Rev 4 of Feb-2018
Thin walled flexible elastomeric cable single core with copper conductors for working voltage above 750 volts upto 1.8 KV/3.0 KV confirming to RDSO's specification no. ELRS/SPEC/ELC/0019, Rev.-4.Size:
PVC Copper Cable Single Core and Multi Core Circular Sheathed Cord with Flexible Conductor (V2) as per IS 694 (Q2) MSE Relaxation for Years of Experience and Turnover No Startup Relaxation for Years of Experience and Turnover No Document required from seller Experience Criteria, Past Performance *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2026/B/7092028 Dated : 09-01-2026 Bid Document 1/7 Number of Auto Extension count 1 Past Performance 20 % Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Required No ePBG Detail Required No
DUSTER CLOTH, PENCIL HB, ERASER, BAMBOO PAPER, DRAWING SHEET, WIPER, PHENYL 1 LTR, HARPIC 500ML, POCHA KAPDA, FILE COVER, DUSTBIN SMALL, DUSTBIN BIG, ACID 1LTR, FOUR FOLD FILE, BALL PEN, GUM BOTAL 700ML, A 4 PAPER PER PKT, PENCIL H, WHITE PAPER PER ... 18WATT, COPPER WIRE 1MM ... 90MTR, COPPER WIRE 2.5MM ... 90MTR, COPPER WIRE 1.5MM ... 90MTR, COPPER WIRE 4MM ... 90MTR, COPPER WIRE 0.75MM ... 90MTR, COPPER WIRE 6MM ... 90MTR, COPPER WIRE 10MM ... 90MTR, COPPER WIRE 40-76 ... 90MTR, COPPER WIRE 23-76 ...
PROVN OF ELECTRICAL PANELS ALONG WITH LT CABLE, CHANGEOVER SWITCHES, GARDEN LIGHTS AND ALLIED WORK AT CAV HQ BUILDING, OFFICER MESS MED REGT, SAPTA SAKTI CANTEEN, YOGENDER SAINIK INSTITUTE AND IFA (SWC) OFFICE UNDER GE (S) JAIPUR AT JAIPUR MIL STN
REPAIR AND MAINT OF LT CABLE,LT PANELS,MCCBs,AND GI EARTHING/CHEMICAL EARTHING PITS/SURGE PROTECTION DEVICE,LIGHTING ARRESTER AND REPAIR/REPLACEMENT OF STREET, SECURITY, HIGH MAST FLOOD LIGHT FITTINGS AND ALLIED WORKS AT 750SU AT AF STN MANDORE
REPAIR REPLACEMENT OF PERIMETER STREET SECURITY LIGHT HIGH MAST LIGHT LT CABLE TIMER INCL SOLAR LED LIGHT AND ALLIED WORK AT MALLAH PUMP HOUSE SEWAR FORT AND PARADE GROUND AND COMPREHENSIVE MAINTENANCE OF STREET LIGHT TIMER SWITCH EARTHING AND CONNEC