Loading…
Loading…
5,054 results • Best match
Replacement of eroded and defective Economizer, LTSH, Reheater Coils, SH Hanger Tubes and SH side wall tubes, lowering/lifting of the coils, carrying out D-meter survey, erection and dismantling of temporary platforms and carrying out DP test on ... Unit-4 Boiler during ...
Laying of Insulation wool and Cladding sheet for the flue gas duct from ID Fan -B discharge gate to Chimney at an elevation of 16.5 Mtrs & for Disconnecting switch duct and its insulator boxes of Transformer rectifiers of all ESP fields in ESP pent ... Stage-II Boiler including ...
Replacement of eroded water wall tubes fin welding of water wall tubes metal build up on eroded portions of water wall tubes and coil tubes providing of carbon steel pads on water wall tubes and rectification of burner bottoms and tops of Unit 1 ... 1 boiler during ...
Replacement of Eroded and defective Economizer, LTSH, PSH, Re heater coils, SH Hanger Tubes and SH side wall tubes, lowering/lifting of the coils, carrying out D-meter survey erection & dismantling of temporary platforms and carrying out DP test on ... Unit-5 boiler during ...
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles, cleat angles in ESP -C pass of 6C22 complete field of Unit 2 boiler , welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables.
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles, cleat angles in ESP -C pass of 2C22 complete field of Unit 2 boiler , welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles, cleat angles in ESP -C pass of 4C12 complete field of Unit 2 boiler , welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables.
Allotment of Ex RCL Land including Plant and Machinery on long term lease annual lease rental basis of 30 years without renewal option on as is where is basis in Zone Z 5 Plot 54.03 Acs at Port area for the purpose of calcined petroleum coke project.
TENDER for Engagement of IRDA Approved Public Sector Insurance Companies/Broker(s) offering rates of Public Sector Insurance Companies for Insurance of Lab Equipment, Plant & Machinery, Buildings and Seed Stocks of APSSDCL for the year 2026-27 w.e.f. January, 2026 for a period of one year
2026-HOR01-GN-129- Task force- Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in EAST ZONE for 04 months.
2026-HOR01-CB-249- Task force Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in SOUTH ZONE for 04 months.
2026-HOR01-GN-123- Task force - Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in NORTH Zone for 04 months.
2026-HOR01-GN-120- Task force - Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in PENDURTHI ZONE for 04 months.
2026-HOR01-GN-121-Task force- Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in WEST ZONE for 04 months.
Refer Pra 1.2 of Part I Instruction to Bidder for details
Break down and repair works Estimate for Belt Replacement, Belt joints, pulley lagging and Cold vulcanizing repairs to the conveyors of the Coal Handling plant for the financial year 2026-27
Job works pertains to the equipment of Air Compressors and ADUs of TMSD-3 Dr.MVR RTPP as and when required during the period from 01.02.2026 to 31.07.2026
Engaging of Machinery for Jungle Clearance at Siva Reddy Colony of Jammalamadugu
Lathe Machine as per IS 6893:1988 (Q2) MSE Exemption for Years Of Experience and Turnover Yes Startup Exemption for Years Of Experience and Turnover Yes Document required from seller Certificate (Requested in ATC), OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 4 Days Inspection Required (By Empanelled Inspection Authority/Agencies pre- registered with GeM) No Evaluation Method Total value wise evaluation Bid Number ( ) : GEM/2024/B/5174570 Dated : 30-07-2024 Bid Document 1/9 EMD Detail Advisory Bank State Bank of India EMD Amount 51354 ePBG Detail Advisory Bank State Bank of India ePBG Percentage(%) (%) 5.00 Duration of ePBG required (Months) ( ) . 17 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. (b). EMD & Performance security should be in favour of Beneficiary, wherever it is applicable., Beneficiary : DIRECTOR DPS ACTING ON BEHALF OF THE PRESIDENT OF INDIA Directorate Of Purchase And Stores, Department of Atomic Energy, Directorate of Purchase and Stores, PMO VS BHAVA ANUSHAKTINAGAR MUMBAI-400094 DPS/CPU/04/A1/4003 (Sharad Bhaialal Hatwar Dps/cpu/04/a1/4033) Splitting
Up keeping and accumulated coal dust cleaning external and internal parts of electrical equipment and accessories such as HT and LT switchgear and motors, lighting fixtures, cable trays along the conveyors , lighting in under/over elevation of Railway Marshaling yard and stacker/reclaimers , BOBR including jungle cutting at yard lighting towers , crushed yard towers and BHEL shed area in DE/EM/CHP/Stage-I, II , III/Dr.NTTPS , during the period from 01-04-2018 to 31-03-2019 for the year 2018-19
Up keeping and accumulated coal dust cleaning external and internal parts of electrical equipment and accessories such as HT and LT switchgear and motors, lighting fixtures, cable trays along the conveyors , lighting in under/over elevation of Railway Marshaling yard and stacker/reclaimers , BOBR including jungle cutting at yard lighting towers , crushed yard towers and BHEL shed area in DE/EM/CHP/Stage-I, II , III/Dr.NTTPS , during the period from 01-04-2018 to 31-03-2019 for the year 2018-19
Procurement of SPARES, Roller Hub and Rocker Arm Roller spares ofLoesche 35.3D Mills at NTPC Kudgi Boiler 3X800MW
20 LTRS WET GRINDER (Q3), 100 RICE BOILER (Q3), FLOOR CLEANER MACHINE (Q3), SS TABLE WITH BASIN (Q3)
NTPC SIMHADRI PAINTING WORKS OF EQUIPMENTS, PIPING AND STRUCTURES In UNIT 1 and 2 BOILER AND TURBINE AREA
Application of Epoxy paint for Structure of Boiler and Critical piping structure of Unit-2 during 2026-27
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles cleat angles in ESP-A pass of any field of Unit-1 boiler welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables for the year 2024-25
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles, cleat angles in ESP -A pass of 2A22 complete field of Unit 2 boiler , welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables during year 2023-24
Lifting and Re erection of badly damaged and bent collecting electrodes, fabrication and erection of new supporting angles cleat angles in ESP-A pass of any field of Unit-1 boiler welding of U guides and carrying of alignment of collecting electrodes to maintain gap between collecting electrodes include all T&P and consumables for the year 2024-25
Sewerage Collection and Conveyance System in Pendurthi area including Construction and Commissioning of Wastewater Treatment Plant withRSGF & Tertiary Treatment of output capacity 46 MLD on Open Technology which can meet the desired water quality ... Pumping Machinery and ...
2026-HOR01-GN-130- Task force - Engagement of one No:5.50 Cum capacity tipper on hire basis along with telescopic pole pruner, chain saw, semiskilled labour and other machinery for pruning, cutting. loading , unloading and lifting of tree braches /tree waste in Bheemunipatnam & Madhurawada Zone for 04 months.
Set of spares for ELGI Make TRC 1000 MN UG Compressor consisting of (1) PIPE I/C TO HP to ELGI Part No: 070408170, Qty-01 No. (2) DELIVERY PIPE ASSY MNUG to ELGI Part No: 07040818A, Qty-01 No. (3) LP OUTLET MANIFOLD to ELGI Part No: 070309770, Qty-01 No.
APGENCO-SRB- Supply, Installation, Commissioning and testing of 4 Tonne air conditioning systems complete with indoor units, Outdoor units, stand concealed copper refrigent piping with insulation, suitable for 440V, 50HZ, 3 Phase to AC supply capable ... reciprocating compressor etc ...
APGENCO-SRB-Supply, Installation, Commissioning and testing of 4 Tonne air conditioning systems complete with indoor units, Outdoor units,stand concealed copper refrigent piping with insulation for suitable for 440V, 50 Hz, 3 phase AC Supply capable ... reciprocating compressor etc ...
PROCUREMENT OF SPARES FOR L amp T MAKE VALVES OF STAGE-II 2X660 MW BOILERFOR NTPC TANDA.
Classifiers cleaning of Ball tube mills including Fabrication and Welding of SS plates 10mm thick to RC feed pipes, transition pieces, fabrication and welding of MS Plates 12mm thick to PF ducts, coal reject lines, conveyor body etc., and Replacement of packing ropes at various expansion joints of Units-5 and 6 Mills as and when required during the year 2020-21.
Transformer oil filtration , replacement of transformer oil of 1 No 400KVA, 6.6KV/433V Power Transformer at S/R-I/II/III &replacement of failed 433V/415V 3-phase 4-wire lighting distribution/welding /SM transformers of different capacities ,laying ... yard, conveyor galleries, ...
Transformer oil filtration , replacement of transformer oil of 1 No 400KVA, 6.6KV/433V Power Transformer at S/R-I/II/III &replacement of failed 433V/415V 3-phase 4-wire lighting distribution/welding /SM transformers of different capacities ,laying ... yard, conveyor galleries, ...
Classifiers Cleaning of Ball tube Mills including Fabrication and Welding of SS plates 10 mm thick to RC feed pipes, transition pieces - MS plates 12 mm thick to PF ducts, coal reject lines, conveyor body etc., and Replacement of Packing ropes at various expansion joints of Units-5 and 6 Mills as and when required during the year 2022-23
Excavating conveyor Belt Size (W) 500 mm x (L) 19500 mm x (T) 10 mm, 315/3 Ply, 5 mm top x 1.5 mm bottom, Open End, Cleat Type Moulded , with Cleats Placed at 75 mm away From The end) Grad as per Plasser part no. RE20.725 for the use of FRM machines. Make:Plasser, Dunlop, Nirlon,MRF,MR,Virshubh,Biswas& Jagriti,
ACTUATOR FOR MOTORIZED VALVE MULTI TURN THREE PHASE ELECTRIC ACTUATOR, MODEL: IQ20F14B4[ IEC EEXD II, VALVE GEARBOX, MAKE ROTORK, MODEL IW6, RATIO 228: 1, INPUT FLANGE F14, OUTPUT FLANGE F25, MECH ADVANTA
Custom Bid for Services - SRVCFCMC OF FLP AC UNITS, Custom Bid for Services - SUPPLY OF COMPRESSOR
Servicing of EOT Cranes with Hoists (Mechanical & Electrical works) for FD fans, PA Fans, APHs, SCAPH, Boiler Recirculation pump, Mills (LHS & RHS), ESPs, Fuel oil pump house and Economizer handling system of Unit-3 Boiler for the year 2025-26 including T&P and consumables.
Certain repairs to Insulation, Cladding sheet and Refractory in Unit-3/Stage-II Boiler for the year 2026-27
Providing labor assistance for emergency coal clearing of coal heaps, slurry coal on all floors of crusher house and jammed coal and wet and slurry coal in crushers, vibrating screens& belt feeder chutes and clearing of heavy coal heaps during rainy season in M-1(crushers), /CHP(M.M)-I&II/Dr. NTTPS. as and when required from 01-04-2026 or from the date of commencement of work to 30-09-2026
Supply and spreading of crusher dust, LDPE sheet and 20 mm HBG metal at 132KV busPT bay, 132KV Kakinada-I feeder bay, 132KV Editha-I feeder bay, 132KV Amalapuram feeder bay, bay underneath the 132KV bus, bay between HV-I & II, bay between HV - II & HV - III, HV -II bay, bay beside HV - III, 132/33KV PTR -I bay and 132/33KV PTR - I bay and 132/33KV PTR - II bay at 132KV SS Ramachandrapuram
Supply and spreading of crusher dust, LDPE sheet and 20 mm HBG metal at 132KV busPT bay, 132KV Kakinada-I feeder bay, 132KV Editha-I feeder bay, 132KV Amalapuram feeder bay, bay underneath the 132KV bus, bay between HV-I & II, bay between HV - II & HV - III, HV -II bay, bay beside HV - III, 132/33KV PTR -I bay and 132/33KV PTR - I bay and 132/33KV PTR - II bay at 132KV SS Ramachandrapuram
Construction of Platform Bed For Placing Biomining Machinery at Compost Yard In Madanapalle Municipality
APGENCO-SRB-Supply, Installation, Commissioning and Testing of 4Tonne Cassette type Air conditioning systems complete with indoor units, Out door Units, stand concealed copper refrigent piping with insulation suitable for 440 V, 50HZ, 3 phase AC ... reciprociting compressor etc., ...
Set of Stainless Steel Hex. Head bolt( Full threaded) of Size: M16 x 40mm, Grade A2- 70 & IS: 1367 Part: 14-1984, along with suitable one flat washer & one spring washer for RR20100 compressor in 3-phase locos. Makes: TVS/APL/Unbrako/KUNDAN. Note: One sample set should be got approved before effecting bulk supply.
REFRIGERATOR SINGLE DOOR 183 LTR capacity, Direct Cool, 5 Star Rated with operating Voltage 230V,50HZ, Rated Power Input:60W, Rated Current:1.0A, With Digital Inverter Compressor of 20 Years Minimum Warranty, with Eco- Friendly Refrigerant preferably R-600a, Confirm to IS:17550( Part1) of Make: SAMSUNG Model.No.RR20D2825CR/NL of Makes: SAMSUNG, Whirlpool, LG, ONLY