Loading…
Loading…
14,163 results • Best match
Sustainability Support to Community Managed Water supply Schemes 2025-26- Nellikunnath WSS in Urangattiri Gramapanchayath-Malappuram Dist
House connection Providing 20mm (3/4 inch) house connection with 15mm (1/2 inch) water meter from existing PVC / HDPE mains up to 110 mm dia., up to a length of 5 m using 25mm Indian Standard Class 6 uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers.
REPAIR AND MAINT OF EXISTING CI/DI/GI WATER SUPPLY RISING MAIN AND MAIN DISTRIBUTION PIPELINE, SLUICE VALVES AND CONNECTED ACCESSORIES , CLEANING OF RAW WATER RESERVOIRS, CLEAR WATER SUMPS AND CONNECTED ITEMS AT LALGARH JATTAN MIL STN
Supply, laying, jointing & testing 3-layer PP-R Polypropylene random copolymer) concealed pipes 25 mm dia SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings as socket, elbow, reducer, end cap, male & female threaded elbow, male & female threaded socket, tee, wall clamp, & other accessories fixed complete to walls, ceilings or in floors etc, complete all as specified and directed by Engr-in-Charge.
Laying of Parallel/ Dedicated Pipeline, Providing Common Manifold Augmentation of OHR and allied work for better Functionality at SAMBALPUR Piped Water Supply Scheme at Ratua-II Block of Malda District under Malda Division, PHE Dte, Govt. of West Ben
cushion of 1.10mtr. from the top of pipe line including making interconnection with distribution pipes etc. all complete as per drawing direction and satisfaction of the E.I.C. N.B. i) Manufacturer’s test certificate for UPVC pipe & specials to be produced before laying of pipe line. ii) 3rd party inspection of UPVC pipe & specials to be done by CEPET or (India) SGS/NTH Kolkata or as per direction of EIC as per approved vender list. iii)No part payment at any stage on account of supply of materials shall be entertained. iv)Payment will be made on actual consumption of materials. v)UPVC pipes for the works to be supplied as per approved vendor list and as per direction & satisfaction of EIC. No pipes will be allowed beyond recommendated vendor list. vi)Submission of drawing of pipe line with statement of materials consumed between node to node points against each R.A. & final bill.if so. vii) Any deviation from required clear cover of 1.10mtr.due to site adverse condition, prior permission is to be obtained from EIC and payment for such work will be made on prorate basis over the rate of entire item. viii)All pipe connection shall be completed in all respect and as per directionof EIC. Decision of EIC in this respect is final & binding. In case of any deviation/or any left out pipe connections an amount of Rs.10,000.00 for each pipe connection will be realized/recovered from the bill. (A) Pressure Rating : Class - III (ii) Laying of pipe line including cost of pipe & fittings/specials but excluding cost of valves.
Sustainability Support to Community Management Water Supply Schemes- 2025-26 - Thengida Meethal WSS, Kizhakkayil Meethal WSS, Jaminimukku WSS, Thiruppurath WSS in Naduvannur Gramapanchayath - Kozhikode District
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerincharge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
REPAIRS AND DAY TO DAY MAINTENANCE TO PLUMBING SANITRARY FITTINGSJOINERY AND ALLIED WORKS AT NCSR CEDU CMDC CCOSW HQ 1 EW BDE 135 EW EME BN 9 R AND O HELIPAD COLONY NSOI SPORTS COMPLEX BIKRAM PARK TARAMOUNT AND AOR OF AGE BR-II GE SOUTH UDHAMPUR
Taking down bib taps/pillar taps/mixers/shower/water tanks etc and making good and serviceable and refixing to same including minor repairs and repair/replacement of accessories like spindle, rubber kit, screws and similar items to make serviceable and all plumbing works etc complete all as specified.
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY ALONG WITH CONNECTED WORKS OF PUMPING DISTRIBUTION SYSTEM AT ZONE I AND II AREA UNDER GE DINJAN
Supply only 65-70% Calcium hypochlorite granules (in 45kg Bucket ) for treatment of water disinfiction complete all as specified and directed. Note : (a) The contractor has to produce manufactures test certificate in original indicating Batch No date of manufacturing and paid Vrs while supply of Calcium hypochlorite granules. (b) The disinfectant shall be brought at site in sealed plastic container of appropriate capacity / size. (c) The brand of chemical shall be approved by GE before in corporation of work. Batch No and date should be marked on every container. (d) The approval of product and brand should be approved by E-in-Cs branch New delhi . The product should be efficient biocide, for treatment of drinking water.