Loading…
Loading…
6,236 results • Best match
MTPS I BM Unit I Boiler Pressure parts AOH 2026 Removal and refixing of Skin casing sheet and insulation for attending boiler 1st pass water wall tubes and 2nd pass steam cooled wall tube rectification works etc
MTPS I TM IV Unit III Unit IV Preventive Breakdown maintenance works Repairing works of Air Compressors Make KG Khosla Model No 2HA2QT Air Dryers Make TRIDENT IR on as when required basis for a period of one year for the year 2026 2027
MTPS I TM UNIT I Complete Overhauling of HP Bypass LP Bypass Spray Valves Oil Supply Unit during AOH 2026 2027
MTPS I TM Unit I II III Removal and Re insulation of HP IP control Valve area Spindle leak off lines Gland steam pipes of LP front rear in Main Turbine during Annual Maintenance work 2026 27
MTPS I M I CA CWS I Overhauling of Traction drive and flocculator drive Gear Box in Clarifier I during AOH 2026 2027 of Unit I
MTPS I M I CA CWS I Overhauling of sludge disposal pump and Cold and hot water tunnel vent valves Air Vent valves and allied works
MTPS I M I CA CWS I Replacement of corroded and eroded blow down pipe line in cooling tower I and a portion of recirculation water pipe line in Cooling water pumps of stage I
MTPS I TM I Unit I Inspection and Overhauling of Oil Vapour Extraction Fan assembly Cleaning of strainer assembly and cooling water lines of ESV IV during AOH 2026 27
MTPSI TM Unit I Overhauling of OLCTC System Pump LHS RHS Overhauling 1600 mm Butterfly valve and its actuator gear box of cooling water inlet and outlet pipe lines in condenser Inspection Cleaning of Condenser CW box steam side Hot well etc
MTPS I TM Unit I Cleaning Hydraulic Testing of Lub oil Coolers Working oil coolers Dismantling cleaning and assembling of Suction Strainers of BFPs CEPs Renewal of BFP leak off line and suction discharge flange Gaskets
MTPS I TM UNIT III Overhauling of Screw Air Compressor 3A 3B of make Ingersoll Rand Model No R132 i 7 5 AC
MTPS I TM Unit I Annual Overhauling and gasket renewing of Valves in Feed Water Main Condensate and Extraction Steam lines in Unit I during Annual Overhauling 2026 27
MTPS I TM Units I to IV Attending the preventive breakdown maintenance works of Valves Pipe Lines reducers by cutting welding gasket renewing of valves flanges and Overhauling of defective passing Valves in Units I to IV as and when required basis
MTPSI TM Unit I II Preventive Breakdown maintenance works Repairing works of Air Compressors Make KG Khosla Model No 2HA2QT Air Dryers Make Khosla on As When required Basis for a period of One year in the year 2026 2027
MTPS I TM Division Load Testing of 2Nos 125 30T Station EOT Cranes during 2025 2026
MTPS I BM DM Plant Neutralizing pits below ground level size 9.5m X 6.5m X 3.5m Cleaning and removing of sludges of acidic etc
MTPS I BM Unit I AOH 2026 27 Cutting and Patch welding on the eroded portion of the FG duct from ECO outlet to APH inlet etc
MTPS 1 BM Units I and II Retubing of Lub oil cooler nest for Air Pre Heaters with 90 10 cupro nickel tubes including the cost of materials
MTPS I BM Unit I Rotating parts AOH 2026 27 Overhauling reconditioning of CERM and EERM gear boxes ID PA FD fans gate actuators and other related works etc
MTPS I BM Unit I Annual overhauling 2026 27 Overhaul of ESP AB and CD pass Internals and related works
MTPS I BM Unit I Boiler Pressure parts AOH 2026 Overhauling of HP LP valves and replacement of defective valves
MTPS I BM DM Plant Cleaning and painting of inner surface area of Unit I to IV CST with one coat of epoxy paint during AOH COH 2026
MTPSI Mill Plant Unit I Renewal of eroded worn out Expansion Joints1A 1B 1C Providing guard plates for the expansion joints Patch welding of eroded portion of hot air ducts welding of worn out portion of hot air duct joints and providing insulation
MTPS I - Civil Circle Up keeping of Central office Building and Dispensary in Thottilpatty camp area by cleaning of Toilets and Sweeping works for the period of one year from the date of Commencement
MTPS I CA CWS II Unit IV Complete dismantling inspection Overhaul including renewal of wornout pump components and assembling of CWP 4B in stage II
MTPS I Civil Circle - Providing one number Diesel / Petrol driven Tata Sumo or equivalent Vehicle on hire basis for the official use of the Executive Engineer Civil Division II Mettur Thermal Power Station I
MTPS I TM Stage I Unit I II Load testing of 2 Ton capacity EOT crane 3 Ton capacity electrical Hoists in LP Bypass valves LHS RHS and movable 1 ton chain block trolleys in pumps and Compressor area for the year 2026 27
MTPS I BM Unit I Boiler Pressure Parts AOH 2026 Cleaning of boiler structures from 0 to 52 m Level etc
MTPS I BM Unit I AOH 2026 27 Renewal Reconditioning of various Saw tooth expansion joints in FG ducts and Air ducts and other related works etc in both A and B sides
MTPS I BM Unit I Boiler AOH 2026 Reconditioning and hard facing of used and worn out coal nozzles fixing of divider plates and allied works
MTPS I BM Unit I Boiler pressure parts AOH 2026 Dismantling cleaning and rectification of defective seal trough seal plates SS woven wire mesh providing patch plate
MTPS I BM Unit I Boiler Pressure parts AOH 2026 27 Maintenance of boiler drum and all safety valves and allied works
MTPS I M I CA CWS I Dewatering complete cleaning and sludge removal Cleaning with bleaching powder painting the structure of Clarifier I during AOH 2026 27
MTPS I TM UNIT I Renewal of piston seal piston rod packing in HP / LP Bypass Valves and its Spray valves Actuators including servicing of Oil filters during AOH of 2026 27
MTPS I TM Unit I Carrying out Bullet cleaning by specially designed Phosphor Bronze Bullet shot of LHS RHS of condenser tubes in condenser during AOH of 2026 27
MTPS TM Unit I Cleaning and painting of inner and Outer portion of Receiver Tanks of 1 2 for Instrument Air system Service Air system renewal of Manhole door gaskets Overhauling of Safety valves of Receiver Tanks overhauling of 150mm Gate valve
MTPS I TM Unit I Removal of insulation and providing re insulation to pipe Lines valves Deaerator main flange Gland steam cooler Low pressure heater Flash tanks and its accessories and disposal of waste insulation materials for Unit I Annual overhaul
MTPS I TM Unit I Renewal of Gasket at water box side tube nest side condensate inlet and outlet flange inspection and cleaning of tube nest and hydraulic testing of LPH 2 3 4 GC 1 Ejector 1B and Renewal of Gasket at Deaerator main flange Deaerator
MTPS I TM Unit I Overhauling and Flange gasket renewing of valves in Heater Drain Pegging Steam to Deaerator Condenser air Auxiliary steam and Drain Water lines and gasket renewing of valves in Unit I during AOH 2026 27
MTPS I BM DM Plant Unit I to IV AOH COH 2026 Overhauling of Hot well makeup pumps 8 Nos and Boiler fill pump 4 Nos
MTPS 1 BM Unit I AOH 2026 27 ESP AB and CD Pass Hoppers strengthening of the welding joints patch welding the eroded portions and other related works etc
MTPS 1 BM Unit I Inspection Renewal of Guide bearing in Air pre Heater A and B sides and dismantling cleaning inspection and reassembling of air seal assembly etc and other related works
MTPS I BM Unit I Boiler Pressure Parts Rectification of damaged ERV silencer assembly and other related works during capital overhaul 2026
MTPS I M I Circle BM Rotating parts Units I and II load testing and certification of movable trolleys chain blocks located above Primary Air Fan Forced Draft Fan APH Induced Draft Fan and ESP area
MTPS I BM Unit I Boiler pressure parts AOH 2026 Disposal of Ash from Pent house Eco hopper deflection slope rear arch room and boiler roof area and allied works
MTPS I - Civil Circle Annual Over haul 2026-27 - Cleaning of columns, Beams, drift eliminators, louvers and stacks in cooling tower cells including removal of silt/slush in cold water basin in Cooling tower-I
e-Tender for the supply of various type of pulleys for belt feeders - 2 items as per annexure enclosed
MTPS I BM Unit I AOH 2026 2027 Renewal of Various types of heating elements in APH 1A and 1B and other related works
MTPS 1 BM Unit I AOH 2026 27 Application of hard setting sealing compound of Eromat 1003 on the erosion prone area of the Air Pre Heater outlet Flue gas duct both A and B sides
MTPS I BM Unit I Pressure parts Removal of deteriorated and peeled of Insulation and reinsulation of Boiler burner corners and SADC with new insulation