Loading…
Loading…
5,914 results • Best match
MOEI and fans, Power plug street compound light and RMO sub-station equipmenets stand by 320 KVA DG set, pump set for water supply, wet riser i/c sprinkler system, automatic fire alarm, PA and sound system in CCRAS building at Janakpuri New Delhi. (SH: Comprehensive annual maintenance of 4 nos 13 passenger lift (2 nos lift near receiption 2 lift near auditorium) OTIS make at CCRAS building Janakpuri New Delhi
Supply, Installation, Testing and Commissioning of Fire suppression system for various Electrical Panels in ward Block for 100 beds (Ground to 3rd Floor) in BalakRam Hospital in Timarpur, Civil Line Zone
Routine Maintenance of EI , Fans, compound light and Routine maintenance and operation of DG Set, PA System, pump set, Wet Riser system , Fire Alarm system
SH. RMO EI and Fans, Compound light and RMO of Wet Riser and Sprinkler System, Fire Alarm System, Passenger Lifts, Pump Set and DG Set
Day to Day and Anuula repair & Maintenace of KVS (HQ) Building, New Delhi. Subwork/Packages: Repairing of adressable fire alarm system at KVS (HQ) Building.
rmo e and m serives at president estate museum II new delhi Subwork/Packages: comprehensive maintenance and operation of notifier make addressable fire alarm system
rmo e and m services at president estate museim-ii new delhi Subwork/Packages: comprehensive maintenance and operation of notifier make addressable fire alarm system
Sub Head- Replacement of Defective/ Damaged Fire Alarm and Detection System at Navyug School, Mandir Marg and Balance Work of Mohan Singh Place, New Delhi
Sub Head- AMC for Fire Alarm and Detection System at Chander Lok Building, Pragati Bhawan, Palika Bazar, Vidyut Bhawan, Working Girls Hostel, and Indira Niketan
Sub Head- AMC for Semi Addressable Fire Alarm and Detection and Public Address, Video Conferencing and EPABX Systems installed at Disaster Management Centre, Humayun Road
Refilling of Fire Extinguishers of Co2 type and ABC dry powder type installed inside the buildings and other common spaces at Pocket 11 Sector G7/G8, Narela.
Refilling of Fire Extinguishers of Co2 type and ABC dry powder type installed inside the buildings and other common spaces at Pocket 6 Sector G7/G8, Narela.
Tentage Service Lumpsum Based - FMGE Certificate Distribution Event; Floorings, Lighting, Tent Rentals, Furniture & Equipment Rentals, Maintenance & Support, Safety Measures, Dismantling and Removal, INSURANCE, Fire Extinguishers, Waiter, Electrical ..
Tentage Service Lumpsum Based - FMGE Certificate Distribution Event; Floorings, Lighting, Tent Rentals, Furniture & Equipment Rentals, Maintenance & Support, Safety Measures, Dismantling and Removal, INSURANCE, Fire Extinguishers, Waiter, Electrical ..
Installation of fire hydrants in the area of pilot project (A-23) Jama Masjid, Chawri Bazar, Nai Sadak and Esplanade Road adjoing areas under committee constituted to submit the recommendations on the notice received from NHRC under EE(Central)-I.
Construction of Income Tax Departmental Guest houses at A-3/4, Vasant Vihar, New Delhi and at 27 Bazar lane, Bengali Market, New Delhi including Internal Water Supply, Sanitary Installations and Drainage, Internal Electrical Installations, ... Lift, Firefighting and ...
Water proofing treatment of fire fighting tanks at terrace of G-8 towers in all four groups of Mega Housing Project D-6, Vasant Kunj.
MO E&M Services at Supreme Court of India New Delhi Subwork/Packages: Painting of Fire Fighting Equipment and Electrical Equipment at Additional Building Complex
MO E&M Services at Supreme Court of India New Delhi Subwork/Packages: Various Fire Fighting work at Mc Setalwad and CK Daftary Lawyers Chamber
As per tender documents.
Providing and fixing EPBAX Data voice system, Digital safety system and fire safety equipment in Sports Division - 2. (Specialized work).
Comprehensive Annual Breakdown Maintenance Contract of Semi addressable/Conventional type Fire Detection System installed at different elevated Metro Stations of DMRC Phase-I, II and III
Annual Maintenance Contract of Fire Detection and Auto Dialer system at various locations in Operational Area, IGI Airport, for the Year 2020-21 and 2021-2022.
Sub-Head - Comprehensive AMC for Fire Alarm and Detection System at Palika Parking, Mohan Singh Place, Shaheed Bhagat Singh Place and Palika Place in NDMC area.
RMO of E and M services at President Estate Museum II New Delhi Subwork/Packages: Providing service of manpower and maintenance of addressable fire alarm system
RMO of E and M services at President Estate Museum II New Delhi Subwork/Packages: Providing service of manpower and maintenance of addressable fire alarm system
Sub Head - Repairing and Replacement of Defective Fire Alarm System at Polyclinic SBS, Kaka Nagar Barat Ghar, Jor Bagh Community Centre and Golf Link Community Centre.
Sub Head- P/F/T/C of Fire Alarm System in Harish Chander Mathur Lane, Lodhi Road, Tuglak Lane and Sarojini Nagar Dispensaries in NDMC area
Sub Head- Comprehensive AMC for Fire Alarm system (Bosch Make) at Talkatora Stadium, New Annexe Building and Talkatora Stadium (Old Building) and Shivaji Statium (Secutron make)
Sub Head- Comprehensive AMC for Fire Alarm and detection System at Palika Place, Mohan Singh Place, Palika Parking and Charak Palika Hospital (Old and New Building)
watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.3, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system Mounting type Backpack - Configuration ( Shall be mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a Yes - 1/6 backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared 2010 - Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupled with a reducer, hose pipes for discharge of water mist media, extinguishing gun. Yes - Constructional Air Cylinder Material Steel Steel, Ultralight Carbon composite with PET Liner Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. standard foam as per ul 162 or is 4989 standards for fire rating 27 a 233 b 1000 v, Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, concentration shall be 6%. If special foam mention the composition for special, otherwise put NA Water 96%. 1, 2-Ethandiol - Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55, E1000 V (Die Electric Suitability) achieved, to be declared.Write NA if not applicable. FX AGENT - 2/6 Characteristics of extinguishing medium of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable Density 1.11, Viscosity 2.7, pH Factor 8.1, Refractive Index 1.3690 at 20 +/- 2 deg C - Pressure Vessel Material & Capacity (Nominal Charge) Corrosion Free Aluminum alloy vessel of 10 litre capacity . Corrosion Free Aluminum alloy vessel of 10 litre capacity ., Ultralite Carbon Composite with PET Liner of 9 liter capacity Minimum wall thickness of pressure vessel (mm) 5.0 - Extinguishing gun material Stainless Steel - if others Mentions the material for Extinguishing gun, otherwise put NA NA - Extinguishing gun weight (750 grams approx) 750.0 - Length of EN marked Hose 1.3 meter for backpack system Yes - Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 26.0 - performance Air Cylinder Capacity (Ltrs) 2.0 - Air Cylinder pressure (Bar) 200.0 - High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 30.0 - 3/6 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel, ≥ 35 for Ultralight Carbon composite with PET Liner vessel (Bar) Lancing Distance of Gun : More than 12 meter (meter) 12.0 - The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes - Minimum operating time in full throttle for aluminium alloy vessel 24 - Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel NA - System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes - Fire Rating 55 A, 233B, 1000V with Special AFFF Compound as per manufacturer own specn 27 a 233 b 1000 v with standard afff compound conforming to ul 162, 55 A, 1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes - Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes - 4/6 No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes - Pressure Vessel should have CE Marking from Notified body Yes - The air cylinders shall have PESO, Nagpur approval yes - Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes - Test Report No. T7305 - Test Report Date 27/12/2005 - Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted MPA DRESDEN - NOC Letter No. Date of PESO Nagpur for Pressure Vessel G.3(4)40/Misc/2009/67 3 - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Manish Kumar Choudhary 110054, Brig SK Mazumdar Marg Timarpur 2 15 EMD Required No ePBG Required No
watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 49 ) Technical Specifications Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.3, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system Mounting type Backpack - Configuration ( Shall be mounted on a sturdy frame suitably cushioned for comfort, provided with shoulder pads for carrying as a Yes - 1/6 backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared ASKA HIPRESS 9 CARBON-E - Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupled with a reducer, hose pipes for discharge of water mist media, extinguishing gun. Yes - Constructional Air Cylinder Material Ultralight Carbon composite with PET Liner Ultralight Carbon composite with PET Liner Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, concentration shall be 6%. If special foam mention the composition for special, otherwise put NA Water 96%, 1, 2-Ethandiol, Fluorinated surfactant 0.5%, Octylsulfate 1%, Decylsulfate1%, Akylpolyglycoside1% - Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55, E1000 V (Die Electric Suitability) achieved, to be declared.Write NA if not applicable. ASKA 63A - Characteristics of extinguishing medium Density 1.04 (kg/dm3), Viscosity 1.35(mm2/s), 2/6 of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable pH factor 7.8, Refractive index 1.34 at 20 ± 2deg C Pressure Vessel Material & Capacity (Nominal Charge) Ultralite Carbon Composite with PET Liner of 9 liter capacity Ultralite Carbon Composite with PET Liner of 9 liter capacity Minimum wall thickness of pressure vessel (mm) 5 - Extinguishing gun material Stainless Steel - if others Mentions the material for Extinguishing gun, otherwise put NA NA - Extinguishing gun weight (750 grams approx) 750 - Length of EN marked Hose 1.3 meter for backpack system Yes - Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 20 - performance Air Cylinder Capacity (Ltrs) 2 - Air Cylinder pressure (Bar) 300 - High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel, ≥ 35 for Ultralight Carbon composite with PET 37 - 3/6 Liner vessel (Bar) Lancing Distance of Gun : More than 12 meter (meter) 15 - The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes - Minimum operating time in full throttle for aluminium alloy vessel NA - Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel 29 - System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes - Fire Rating 55 A, 233B, 1000V with Special AFFF Compound as per manufacturer own specn 55 A, 1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes - Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes - No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes - Pressure Vessel should Yes - 4/6 have CE Marking from Notified body The air cylinders shall have PESO, Nagpur approval yes - Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes - Test Report No - - Test Report Date - - Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - - NOC Letter No. Date of PESO Nagpur for Pressure Vessel - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Abhishesh Rawat 110003, Safdarjung Airport 49 60
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Office Space; : Refilling of Fire Extinguishers cylinders at 220KV Substation Dev Nagar under Manager(T) Devnagar-Subzimandi; Buyer
Maintenance and modification of fire hydrant pipelines and pipe line accessories of Line-8 (from Janakpuri West to Nehru Enclave metro stations including ancillary buildings, other buildings) and Kalindi Kunj Depot.
Annual operation and maintenance contract of fire protection system in round the clock hours at Kasturba Hospital under CSPZ
Cleaning,Rubbing and painting of fire fighting and sprinkler system Pipe lines and cable trays installed at 457 MS HIG houses sec-18B,Pkt-II Dwarka .
SH 1 RMO of fire fighting ic sprinkler system ..............BG6 Paschim vihar SH 2 RMO of IEI and fans DG Set..........staff quarter at Paschim VIhar
SH Operation and Maintenance of EI and FANS Sub Station HVAC Works Fire Fighting and Wet Riser System Solar Water Heating System Cold Storage Lifts etc
SH Operation and Maintenance of EI and FANS Sub Station HVAC Works Fire Fighting and Wet Riser System Solar Water Heating System Cold Storage Lifts etc
MO E &M Services at Supreme Court of India New Delhi. Subwork/Packages: Remaining fire fighting services work at MC Setalwad and CK Daftary Lawyer Chamber
Sub Head- Annual Maintenance Contract for Wet Riser / Sprinkler System comprising of Fire Fighting appliances Polyclinic, Palika Health Complex, Maternity Centre, Lodhi Road, Charak Palika Hospital
Renovation/Interior fit out Works including Civil Work including, Electrical work including Lighting, HVAC Works, Fire Fighting, Low Voltage, retrofitting work, Furniture and road work etc.
Portable Fire Extinguishers (V2) ISI Marked to IS 15683 (Q2) ( PAC Only ) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Bidder Turnover, OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2025/B/6873670 Dated : 10-11-2025 Bid Document 1/8 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Bid Details EMD Detail Required No ePBG Detail Required No
Portable Fire Extinguishers (V2) ISI Marked to IS 15683 (Q2) ( PAC Only ) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Bidder Turnover, OEM Authorization Certificate *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 1, -- Number of days for which Bid would be auto -- extended 3 Bid Number : GEM/2025/B/6873468 Dated : 10-11-2025 Bid Document 1/8 Number of Auto Extension count 1 Bid to RA enabled No Type of Bid Single Packet Bid Time allowed for Technical Clarifications during technical evaluation 2 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Evaluation Method Total value wise evaluation Bid Details EMD Detail Required No ePBG Detail Required No
MOEI and fans power plug street compound light and RMO sub station Equipments stand by 320 KVA DG set pump set for water supply watering ic sprinkler system automatic fire alarm PA and sound system in CCRAS building at janakpuri New Delhi during 2024 and 25 SH Comprehensive annual maintenance of 4 Nos 13 passenger lift 2 Nos lift near reception plus 2 lift near Auditiourm OTIS make CCRAS building janakpuri New Delhi
Sub Head- Replacement / SITC of various outlived components of Fire Detection and Alarm System time to time wherever required in various NDMC Buildings/Schools/Hospitals/Dispensaries etc
Sub Head- Replacement / S/I/T/C of existing outlived equipments of Fire Alarm System at various NDMC Buildings i.e. Mayur Bhawan, Palika Kendra, Pragati Bhawan etc.
Annual Comprehensive Maintenance contract of BOSCH make addressable Fire Alarm and PA system at 346 MIG M.S. houses at Sector 16 B Dwarka Pkt. II Ph II
Sub Head- Repair and Replacement of defective parts of BOSCH Make Addressable Fire Alarm system at Convention Centre and NDCC PH-II, Jai Singh Road, New Delhi.
Sub Head- Comprehensive AMC for Automatic Fire Alarm and Detection System at Chander Lok Building, Pragati Bhawan, Palika Bazar, Vidyut Bhawan and Working Girls Hostel, Indira Niketan.