Loading…
Loading…
966 results • Best match
Chargeable in contingencies of work 1. Construction of ASI Mess (45 Suits) for 43rd battalion, ITBP Kalna Nogli HP including development of site. 2. Construction of SOs Mess with 45 Suits for ITBP 17th btn Recongeop Distt. Kinnour (HP) 3. ... & Fire Fighting (SH:- ... & Fire Fighting (SH:- ...
E-Tendering for providing and fixing of Fire Extinguishers at HPSEB Ltd Power House Gumma, under RE Division Andhra, Chirgaon, under Gen. Circle Nahan
C/o RCC Ramp and RCC Underground Fire Tank along with Pump House including fire fighting equipments in pump room, providing EI work for RCC ramp and shifting of MGPS lines and electrical earthing etc. for Shri GS Bali Mother and Child Hospital, Tanda, Distt. Kangra (HP). (SH: Providing inspection vehicle for Assistant Engineer (Civil), Madhopur Sub Division, C.P.W.D., Madhopur (Pb) (During 2026-27).
Tender for refilling of fire-extinguishers of different capacities at various sub-stations under 132kV sub-station sub division, Jutogh under ES Division, HPSEBL, Shimla
Exterior and Interior Painting Works for All Buildings (CRB,400 kV GIS Building,220kV GIS, EOT Building,Pump House, Water Tank etc) Boundary Wall, gates, firefighting pipes etc. of 400/220/66 kV GIS substation Gumma in Teh. Kotkhai Distt. Shimla H.P.
Tender for Refilling of different types Capacities of fire Extinguisher cylinders installed at Larji Power House under Resident Engineer Larji Power House Division HPSEBL Thalout
Tender for Re-filling of various capacity of already installed Fire Extinguishers of Co2, DCP, ABC and Mechanical Foams at various locations under ED HPSEBL Baijnath.
Construction of building portion, site Development, including water supply and Sanitary Installation, Rain Water Harvesting System Septic Tank, Fire Fighting and Sprinkler System) etc)
Supply, Design and Fabrication of Multipurpose Fire tender including supply of chassis
MOEI at NAAA Yarrows under sub div-I Shimla Subwork/Packages: Repair/Replacement of Defective/Unserviceable part of addressable Fire Alarm System at NAAA Yarrows
ARMO of Electrical and Mechanical Installations, AC Units, Water Cooler, Water Purifiers, Fire Alarm and Detection System at Shimla Airport for the year 2022-2024
Estimate for Refilling, testing and complete commissioning of various type of fire extinguishers, at 3x40 MW SVP Bhaba Power House HPSEBL Bhabanagar for the year 2024-2025.
MOEI at NAAA Yarrows under sub division -I Shimla Subwork/Packages: Repair and replacement of defective/unserviceable parts of fire fighting equipment at NAAA Yarrows
Providing, installation, Refilling, testing and complete commissioning of various type of fire extinguishers, High pressure test (HPT) of extinghuishersalong with necessary spare at 3x40 MW Bhaba Power House..
Renewal / Replacement of existing damaged / depleted M.S. Fire Fighting Pipeline with Carbon Steel Seamless Pipes from intake chamber upto Machine Hall of Bhaba Power House (120MW).
Tender for refilling of fire-extinguishers at 132kV sub-station Maliana, 66kV sub-station Craignano, 66kV sub-station Sainj and 66kV sub-station Hulli under ES Division, HPSEBL, Shimla.
Estimate for refilling , testing and complete commissioning of various types of fire extinguishers, High pressure test (HPT) of extinguishers along with necessary spare at 4x375 KW Rukti Power House.
watermist and caf fire extinguisher high pressure back pack type Watermist And Caf Fire Extinguisher High Pressure Back Pack Type ( 2 ) Technical Specifications * As per GeM Catalogue. Specification Specification Name Values Allowed Values Genric "Conformity to EN 3-7:2004+A1:2007-0 8 standards " The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 30 clauses (3.2, 3.15, 4.2, 4.3, 4.4, 4.5, 6.1, 6.2, 6.3, 7.1.1, 7.1.2, 7.2, 7.3, 7.4, 8.1, 8.2, 9.2, 10.1, 10.2, 10.3, 10.4, 10.5, 10.6.1 & 10.6.2, 14.1, 14.2, 15.2, 15.3, 16.1, 16.2) of EN 3 - 7:2004 + Al: 2007-08 (E) Standard mandatorily applicable for the complete system 8(e)standardmandatoril yapplicableforthecompl etesystem, thecomplet esystemshallbetestedfo rcompliancefromaninte rnationallynationallyacc reditedlaboratoryforco mpliancetoall30clauses (3.23.154.24.34.44.56. 16.26.37.1.17.1.27.27. 37.48.18.29.210.110.2 10.310.410.510.6.1&10 .6.214.114.215.215.31 6.116.2)ofen3-72004al 2007-0 Mounting type Backpack * Configuration ( Shall be mounted on a sturdy frame suitably Yes * 1/6 cushioned for comfort, provided with shoulder pads for carrying as a backpack and a handle to be carried by hand. All materials used shall be of fire retardant type. Backpack shall be supplied with two air cylinders.) Model Number as per Accredited Laboratory Test Report to Be declared ASKA HI PRESS 02/010 * Main Components: Pressure vessel to hold the media with safety valve, compressed air cylinder coupled with a reducer, hose pipes for discharge of water mist media, extinguishing gun. Yes * Constructional Air Cylinder Material Steel Steel Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, B233, Spreading coefficient for special AFFF Compound shall be +5 minimum, concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55, concentration shall be 6%. If special foam mention the composition for special, otherwise put NA Water 96%, 1, 2-Ethandiol, Fluorinated surfactant 0.5%, Octylsulfate 1%, Decylsulfate1%, Akylpolyglycoside1% * Commercial Brand Name of the Special foam (fire extinguishing medium) as per accredited laboratory test report wherein higher fire ratings i.e A55, E1000 V (Die Electric Suitability) achieved, to be declared.Write NA if not applicable. ASKA FX AGENT * 2/6 Characteristics of extinguishing medium of Special AFFF Compound (manufacturer own specifications) with infrared spectrogram to be furnished.NA if not applicable Density 1.12, Viscosity 2.0, pH factor 8.5, Refractive index 1.3692 at 20 ± 2deg C * Pressure Vessel Material & Capacity (Nominal Charge) Corrosion Free Aluminum alloy vessel of 10 litre capacity . Corrosion Free Aluminum alloy vessel of 10 litre capacity . Minimum wall thickness of pressure vessel (mm) 5 * Extinguishing gun material Stainless Steel * if others Mentions the material for Extinguishing gun, otherwise put NA na * Extinguishing gun weight (750 grams approx) 750 * Length of EN marked Hose 1.3 meter for backpack system Yes * Weight of fully charged Backpack system between 25kg to 27kg having Corrosion Free Aluminum Alloy vessel and below 20 kg having Ultralite Carbon Composite with PET Liner Vessel for 25.9 * performance Air Cylinder Capacity (Ltrs) 2 * Air Cylinder pressure (Bar) 200 * High Pressure Type (Dynamic Operating pressure to be tested in the accredited laboratory test report which will be considered as high pressure for as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) ≥ 30 for Aluminium vessel, ≥ 30 * 3/6 35 for Ultralight Carbon composite with PET Liner vessel (Bar) Lancing Distance of Gun : More than 12 meter (meter) 15 * The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes * Minimum operating time in full throttle for aluminium alloy vessel 22 * Minimum operating time in full throttle for Ultralight Carbon composite with PET Liner vessel 29 * System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause 7.4 of EN 3-7:2004+A1:2007-08 standards as per the accredited test report for backpack system. Yes * Fire Rating 55 A, 233B, 1000V with Special AFFF Compound as per manufacturer own specn 55 A, 1000V with Special AFFF Compound as per manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes * Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body). Yes * No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur Yes * 4/6 Pressure Vessel should have CE Marking from Notified body Yes * The air cylinders shall have PESO, Nagpur approval yes * Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes * Test Report No - * Test Report Date - * Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - * NOC Letter No. Date of PESO Nagpur for Pressure Vessel - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rohit Verma 172201, OFFICE COMPLEX NJHPS SJVN JHAKRI 2 15
Sub Head Construction of Food Court, Toilet block, shops, Landscaping, External development , Finishing of Hotel and Recreation block, External and internal E.I work and fire fighting etc.
Development of permanent campus of IIM Sirmaur at Dhaula Kuan, District Sirmaur, Himachal Pradesh. (SH: RMO, 2X250 KVA Substation in ESS-1, 2X400 KVA Substation in ESS-2, 2X1000 KVA in ESS-3 11 KV/0.433 KV, Electric Substations, 2X500 KVA DG sets. ... UGT-2, Fire Fighting , ... UGT-2, Fire Fighting , ...
Student Chair with Desk Pad, Presenter, Pointer Stick Antenna Type, Repair and Maint of online UPS, Pellets for Paint Ball Gun, Fire Fighting Haus Pipe, Foldable Iron Ladder
Tender for refilling of fire extinguisher at 132/33/11 kV Sub- Station at Gondpur.and 132/33/11 kV Sub- Station at Kala-Amb Under Electrical System Division HPSEBL Nahan
1) MOEI, replacement of lamps and tubes, fire alarm, EPBAX and RMO pump set and DG set at Grand Hotel Shimla 2) MOEI, RMO pump set installed at GPRA Grand Hotel, Longwood, Craigdhu Hill under Sub Divn.-II Shimla 3) Replacement of lamps and tubes, maintenance of geysers and RMO pump set in Army Houses at Longwood, Craigdhu etc. SH- Operation and routine maintenance of electrical installations, RMO DG Set, Substation, LT Panels, pump set etc.
Water Tender/Foam Tender for Fire Fighting (Q3) MSE Exemption for Years of Experience and Turnover No Startup Exemption for Years of Experience and Turnover No Document required from seller Experience Criteria, Bidder Turnover, Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience Turnover Criteria, the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer ? ? Do you want to show documents uploaded by bidders to all bidders participated in bid? Yes (Documents submitted as part of a clarification or representation during the tender/bid process will also be displayed to other participated bidders after log in) Minimum number of bids required to disable automatic bid extension 3, -- Number of days for which Bid would be auto -- extended 10 Bid Number : GEM/2025/B/6955786 Dated : 02-12-2025 Bid Document 1/8 Number of Auto Extension count 2 Bid to RA enabled Yes RA Qualification Rule H1-Highest Priced Bid Elimination Type of Bid Two Packet Bid Time allowed for Technical Clarifications during technical evaluation 4 Days ( )/Inspection Required (By Empanelled Inspection Authority/Agencies pre-registered with GeM) No Estimated Bid Value 20551540 Evaluation Method Total value wise evaluation Arbitration Clause No Mediation Clause No Bid Details EMD Detail Advisory Bank State Bank of India EMD Amount 411040 ePBG Detail Advisory Bank State Bank of India (%) ePBG Percentage(%) 5.00 ( ) Duration of ePBG required (Months). 24 (a). EMD EXEMPTION: The bidder seeking EMD exemption, must submit the valid supporting document for the relevant category as per GeM GTC with the bid. Under MSE category, only manufacturers for goods and Service Providers for Services are eligible for exemption from EMD. Traders are excluded from the purview of this Policy. (b)., EMD & Performance securityshould be in favour of Beneficiary, wherever it is applicable. Beneficiary : A.O Cash BBMB Talwara Bhakra Beas Management Board, Chandigarh, Bhakra Beas Managemet Board, BHAKRA BEAS MANAGEMENT 2/8 BOARD, Ministry of Power (A.o Cash)
Cutting of grass along the road to power house stage II, path to surge shaft, path to fire fighting tank and from switchyard etc of Ganvi Power House Stage II.
Restoration/ repair of emergency cooling cum fire fighting pipe line which was damaged due to sliding of boulders from upside hill near butterfly valve i/c clearing of grass etc.
Networking Switch, Matrix Switcher, Fire Alarm System, Biometric System Dual Factor Attendance and Access Control, Visualizer A4 Size, Mobile cum Cell Phone Jammer, CCTV System Complete Set of Four Bullet Cameras
Master Control Unit, Cylinder assmbly filled with of clean agent and other items as per TS, Mandatory Spares As Per Detailed In TS/Scope Of Work Enclosed., Installation, Testing, Commissioning of Automatic Fire Suppression System as per SOW enclosed
C/O Rain water harvesting tank for firefighting, GRG falce ceiling, HPL board and aluminium works
Providing services of inspection vehicle along with driver etc, complete to officials of CPWD. Chargeable to contingences of work construction of Hostel Building, OPD Block and Ramp for Composite rehabilitation Centre CRC ie SITC of internal EI and ... cabling Fire Fighting with ...
Supply and installation of Submersible pumping machinery with allied accessories Deposit Work
Tender for Refilling of old fire extinguishers at various S/Stn under ED HPSEBL Thalout Ch to RM of un-manned sub-station with VCB at Nagwain under ESD Nagwain for the year 2024-25
Prov. for refilling of Fire Extinguishers, Replacement of defective Spare Parts and Hydraulic pressure testing at 33/11kv 2x3.15, 1x3.15 and 2x2.5 MVA S/Stn at Sarahan, Kheri (machher) and Rajgarh under Elect. Division Rajgarh.
Drilling by DTH/ODEX percussion/Calyx/RC Portable rigs
Prov. for refilling of Fire Extinguishers, Replacement of defective Spare Parts and Hydraulic pressure testing at 33/11kv 2x3.15 MVA Sub-Station Sarahan, 33/11 kv Sub-Station Rajgarh, Kheri and Charna and panog Under ED Rajgarh
Providing undrground storage tank 1 00,000 ltrs capacity for fire fighting Pannel Room along with Pumping Machinery, laying pipes etc. in zonal Hosptial Dharamshala Distt. Kangra H.P. Sub Head Construction of Pump House. Deposit Work