Loading…
Loading…
1,030 results • Best match
Custom Bid for Services - Annual Maintenance Contract and calibration of 20KN Capacity Automatic electronic Tensometer without spare Parts as per scope of work Similar Category Testing Service for On-Board/Commissioned Equipment/Instrument related to Plant
Custom Bid for Services - Annual Maintenance Contract for one 80 MT pit type fully electronic weighbridge installed near rail side at ICDTughlakabad New Delhi including annual stamping and calibration charges from Weights and Measurement Department f..
3/4" SQ DRIVE RATCHET TYPE TORQUE WRENCH CAP- 14-70 Kgf.m (135-675NM), as per Drawing: IS: 6789-2003 OR LATEST WITH CALIBRATION CERTIFICATE SHOULD BE PROVIDED BY THE FIRM, WITH DETAILS OF MASTER EQUI
Servicing calibration and testing of Substation equipments
Rate Contract for Engagement of TPI for Supervision of Works at Retail Outlets under Divisional Offices of Delhi State Office
REPAIR REPLACEMENT OF WORN OUT 33KV SWITCHGEAR PADS AND REPLACEMENT OF 110 V 52V 24V BATTERY BANKS MAINTANENCE OF POWER OUTDOOR INDOOR DISTRIBUTION TRANSFORMER CT PT LA LINE DIFFERENTIAL RELAYS PROTECTIVE RELAYS WITH ACCESSORIES CALIBRATION OF RELAYS
CA NO CWE/PM/SP-01/2020-21 REPAIR, RENEWAL, MAINTENANCE, SERVICING, CALIBRATION OF HT EQUIPMENTS, CABLES, EARTHING AND ALLIED E/M WORKS AT VARIOUS SUB STATIONS AND AREA UNDER WAC (U) SUBROTO PARK, DELHI CANTT-10
Breath Alcohol Analyzers, Calibration charges for 2nd year for Breath Analyzer Machine, Calibration charges for 3rd year for Breath Analyzer Machine
Deployment of 12 Nos. of Semi-Skilled and 45 Nos. of Unskilled Staff for C.W.A. (WnS)-I, II and III division under Director (Treatment and Quality Control).(Re-invite)
Deployment of 05 Nos. Skilled, 10 Nos. of Semi-Skilled and 45 Nos. of Unskilled Staff for C.W.A. (WnS)-I, II and III division under Director (Treatment and Quality Control).
Procurement of 3 Channel Benchtop Multi Meter with pH ,Conductivity Electrode And Optional Provisions/Module for DO or Ion measurement for different Quality Control Laboratories under CWA (WnS)-II division.
Request for Proposal for appointment of Third Party Audit Agency for Quality Control/Assurance and SHE Compliance Audit for ongoing Station Redevelopment Projects of Indian Railways as listed in RFP
Cloth Plain Weave Polyester and Cotton- Uniform Cloth- Defence Specification Experience with Gov. Required 1 Year (s) Cloth Plain Weave Polyester And Cotton- Uniform Cloth- Defence Specification ( 750 ) Technical Specifications * As per GeM ... of Quality Assurance , ...
REPAIR/MAINT/CALIBRATION OF VCBS/OCBS, 33/11KV AND REPAIR/REPLACEMENT OF HT JOINTS HT CABLE, SERVICING AND REPAIR/MAINT OF TRANSFORMER OF 33KV, 11KV, SERVO STB AND OTHER CONNECTED WORKS AT DRDE GWALIOR UNDER GE I RND DELHI
REPAIR/REPLACEMENT OF WORN OUT 33KV SWITCH GEAR,11KV CABLE, 110V/52V/24V BATTERY BANKS, MAINTAIN TO POWER OUTDOOR TRANSFORMER CT,PT,LA, LINE DIFFERENTIAL RELAYS, PROTECTIVE RELAYS WITH ACCESSORIES CALIBRATION OF RELAYS/ BREAKERS AT 33 KV SHANKAR VIH
CA NO CWE/PM/SP-43/2019-20 REPAIR, RENEWAL, MAINTENANCE, SERVICING, CALIBRATION OF HT EQUIPMENTS, CABLES, EARTHING AND ALLIED E/M WORKS AT VARIOUS SUB STATIONS AND AREA UNDER CAMERO SUBROTOPARK UNDER GE (AF) SUBROTO PARK, DELHI CANTT-10
ENDLESS BIMETAL BAND SAW BLADE, SIZE-4860 MM LENGTH X 41 MM WIDTH X 1.3MM THICK, TPI= 2/3, GRADE- M-42, PO
Deployment of 05 Nos. Skilled, 10 Nos. of Semi-Skilled and 45 Nos. of Unskilled Staff for C.W.A. (WnS)-I, II and III division under Director (Treatment and Quality Control). (Re-invite)
As per Tender Document
Visual inspection to estimate the existing structures load and assess the RCC members for NDT tests. Inspect the structural damage area and same mark on drawing. All as per brief specifications., Rebound Hammer test to assess the hardness of concrete and correlation with core compressive strength as per IS 13311 Part 2 Hardness of Concrete, Ultrasonic pulse velocity UPV as per IS 13311 Part I measurements on the RCC elements to find out the quality of concrete., Ferro scanning rebar Scan To locate the RCC element in wall and also check the steel bars and its details i.e. spacing and its estimation., Core cuttting Take out the sample of cylindrical concrete core as per IS 516 1959, Compressive strength To check the compressive strength of cylinderical concrete, Half cell Potential test to confirm the corrosion possiblity in RCC members, Concrete cover meter test., Carbonation Test To detect the depth and status of carbonised concrete members area.
Reagent Calibration, Cleaning Solution, Electrolyte Control, Thermal Roll, Urine Diluent
Custom Bid for Services - ENGAGEMENT OF RATING AGENCY OR ITS SUBSIDIARY FOR VETTING AND CALIBRATION OF CREDIT RISK RATING MODELS OF IREDA PARENT COMPANY AND DEVELOPMENT OF MODELS FOR IREDA SUBSIDIARY COMPANY AT GIFT CITY Similar Category Empanelment of Consultants/Service Providers
DSO/ENG/LT/10/2018-19
Bench Grinding Machine 1/2 HP, 3 Phase, 2880RPM, Copper Winding With 200 x 20 mm Grinding wheels, make : Bosch, Makita, RalliWolf, PRIYA-RAJKOT only. Item to be supplied along with warranty, Valid Calibration and Test certificates from Central Govt/NABL/ILAC accredited LABs.
CALIBRATION OF RELAYS BREAKERS 33 KV GIS PANEL AT SHANKAR VIHAR SUB STATION REPAIR REPLACEMENT OF WORN OUT SPARES OF 33/11KV SWITCH GEAR HT 33/11KV CABLE 110V/52V/24V BATTERY BANKS MAINTAIN TO OUTDOOR TRANSFORMER CT PT LA LINE DIFFRENTIAL RELAYS PR
CALIBRATION OF RELAYS/BREAKERS 33 KV GIS PANELS AT HQ NSB-II REPAIR/REPLACEMENT OF WORN OUT SPARES OF 33/11KV SWITCH GEAR HT 33/11KV CABLES 110V/52V/24 VOLT BATTERY BANKS MAINTAIN CT PT LA LINE DIFFERENTIAL RELAYS PROTECTIVE RELAYS WITH ACCESSORIES
Customized AMC/CMC for Pre-owned Products - CAMC for one Electronic Platform type weighing Scale of Cap 1OO0 kg installed at export W H ICD TKD including annual stamping & calibration charges from W & M Depart for a period of 03 Years; AS PER TENDER;..
Procurement of Ammonia Selective Equipment (Specific Ion Meter/Multi-Parameter) with additional electrode for Ammonia, Dissolve Oxygen and Nitrates with are compatible to same equipment for Quality Control Laboratories under CWA (WnS)-II Div. WTP HP.
PROCUREMENT OF FULLY AUTOMATED IMMUNE ANALYZER WITH INBUILT CALIBRATION AND FACILITY(LIAISON)
Granite Base Mechanical Bed along with guide ways for line scale calibration
(1) RMO E and M Services at UTCS Bldg. Vishwas Nagar, Shahdara Delhi. (2) RMO E and M Services in KKD Court (Court Block) ACI, B and JKL at Distt. Court KKD Delhi. (SH- Servicing and Calibration, Testing of 11 KV HT/ LT Panel and transformer etc.)
Digital Bore Gauge of measuring range : 150-250 mm with Digital ABS Dial Gauge Indicator, least count : 0.001 mm, Accuracy : 0.003 mm with Calibration Certificate from NABL accredited lab. Make/ Brand : MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
Digital bore gauge of measuring range :50 -150 mm with digital ABS dial gauge indicator ,least count : 0.001 mm, Accuracy ; 0.003 mm with calibration certificate from NABL accredited lab.Make/Brand :MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
Digital bore gauge of measuring range :50 -150 mm with digital ABS dial gauge indicator ,least count : 0.001 mm, Accuracy ; 0.003 mm with calibration certificate from NABL accredited lab.Make/Brand :MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
Digital Bore Gauge of measuring range : 250-400 mm with Digital ABS Dial Gauge Indicator, least count : 0.001 mm, Accuracy : 0.003 mm with Calibration Certificate from NBL accredited lab. Make/ Brand : MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
Digital Bore Gauge of measuring range : 150-250 mm with Digital ABS Dial Gauge Indicator, least count : 0.001 mm, Accuracy : 0.003 mm with Calibration Certificate from NABL accredited lab. Make/ Brand : MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
Digital Bore Gauge of measuring range : 150-250 mm with Digital ABS Dial Gauge Indicator, least count : 0.001 mm, Accuracy : 0.003 mm with Calibration Certificate from NABL accredited lab. Make/ Brand : MITUTOYO/BAKER/INSIZE or similar. Suitable carrying case for each bore gauge is to be provided.
SITC of Split type air-conditioners for water testing Lab (Amrit Bhawan) and Material Testing Lab (Vidyut Bhawan) and various other locations under BM-II(E) division.
Cloth Polyester and Viscose Dope Dyed- Uniform Cloth Average Turn Over of Last 3 Years 3000 Lakh (s) Experience with Gov. Required 3 Year (s) Cloth Polyester And Viscose Dope Dyed- Uniform Cloth ( 1765029 ) Technical Specifications Specification ... of Quality Assurance , ...
helmet combat fiberglass Average Turn Over of Last 3 Years 60 Lakh (s) Experience with Gov. Required 1 Year (s) MSME Exemption For Years Of Experience And Turnover Yes Helmet Combat Fiberglass ( 9307 ) Technical Specifications * As per GeM Category ... of quality Assurance (general ...
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Calibration of Testing Equipments available at substation as per BOQ and scope of work at 220kV RK Puram; Calibration of Testing Equipments available at substation as pe..
Visual inspection as per item descreption., Rebound Hammer Testing as per item descreption. Non Destructive Testing as per item descreption., Ultrasonic Pulse Velocity Test as per item descreption., Carbonation Test as per item descreption., Core Test as per item descreption., Concrete electrical resistivity test as per item descreption., PH value test as per item descreption., Chemical analysis as per item descreption., Slab Load Test as per item descreption., Structural design and drawings as per item descreption., Preparation of BOQ for repair and retrofitting with material specifications and quantity breakup., Vetting of repair and retrofitting scheme from any Govt Engg College.
Renovation Calibration of existing relays and tripping system installed at Old panel of CWPH, HP I.
DNA QUANTIFICATION kITS- POWER QUANT SYSTEM (CAT NO. PQ5008), POWER QUANT CALIBRATION KIT (CAT NO. DS1221)
Bottom nozzle removal, Statutory NDT inspections, Hydrotesting, Inspection and Certification of 3x100 MT above Ground Bullets as Per Rule 19 of SMPV U Rules 1981 at Madanpur Khadar LPG Bottling Plant, New Delhi.
STATUTORY NDT INSPECTION, HYDRO TESTING, EXTERNAL PAINTING AND CERTIFICATION OF PRESSURE VESSELS HORTON SPHERE AND ANTI CORROSIVE TREATMENT AND APPLICATION OF FIRE PROOF COATING ON LEGS SUPPORTS AT DELHI LPG BOTTLING PLANT, TIKRIKALAN
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Partial Discharge testing services for 1 day at 220 kV GIS Substation Peeragarhi; Substation; Service Provider
Repairing, servicing, gas re- filling, testing, calibration, Installation and thermography of CO2 automatic fire suppression system at CWGVSC, Akshardham.
Swelab Lumi L 1 lyse 200ml, Swelab Lumi L 2 lyse 500ml, Swelab Lumi quality control, Swelab Lumi Cleaner bott of 50ml, Swelab Lumi D diluent 20ltrl, Sysmex liquide stromatolyser 4DL 500ml bott, Sysmex cel pack 20 ltr, Sysmex cell clean bott of 50ml, D dimer test, Disttiled water
Calibration and refilling of CO2 Fire suppression System at CWGVSC and Refilling of existing fire extinguisher at PDKP and CSC.