MTPS I TM Unit II Overhauling of TLOCBPs H2CBPs Hydrazine Dozing Pumps Phosphate Dozing Pumps and Heater drip Pumps during AOH of 2025 26
MTPS I CA CWS I Renewal Replacement of most corroded and eroded pipes of various sizes in the existing Hot water header line in cooling Tower II during AOH 2023 2024 of Unit II
MTPS TM Unit II Cleaning and painting of inner and Outer portion of Receiver Tanks of 1 2 for Instrument Air and renewal of Manhole door gaskets and Overhauling of Safety valves of Receiver Tanks Overhauling of Silica gel type Air drier
MTPS I TM Unit III Overhauling of OLCTC System Pump LHS RHS Inspection Cleaning of Condenser CW box steam side Hot well OLCTC System Ball collecting Screen Overhauling of 200 mm condenser air release cum vacuum breaking valve etc
MTPS I - Civil Circle Up keeping of D.M.Plant, Fuel Oil Pump House, Transport Office, Workshop, Ash Slurry Pump House Stage I and II, ESP I to IV Control room, MCC I SWGR etc., by cleaning of toilets for the period of one year
MTPS I - Civil Circle Up keeping of New I.B and Old I.B by Cleaning of toilets, sweeping the road all-round the Inspection Bungalows, cobweb cleaning, sweeping and mopping inside of all suits of IB and annexure building and maintenance of gardens
MTPS I TM I Unit II Annual Maintenance work in Main turbine and its Auxiliaries during 2022 23
MTPS I TM Unit I Removal and Reinsulation of HP IP control Valve area Spindle leak off lines AND Gland steam pipes of LP front and rear in Main Turbine during Annual Maintenance work 2021 22
MTPS TM I Overhauling Load testing and Certification of 15 Nos Chain Blocks of various capacities available in the area of Turbine Lub oil Coolers Seal Oil Coolers and Main Oil tanks in Unit I to IV during 202122
MTPS I TM Unit IV Cleaning and Hydraulic Testing of Lub oil Coolers and Working oil coolers Dismantling cleaning and assembling of Suction Strainers of BFPs and CEPs etc
MTPS I - Civil Circle - Replacing the damaged cover slab by new cover slab over cable trench in Switchyard at MTPS I
MTPS I BM Unit IV Rotating parts Removal of deteriorated and peeled off insulation and renewal with new insulation materials in ID fans 4A and 4B outlet vertical duct chimney horizontal duct ID fan A and B inlet common duct header Top Front and Rear
MTPS I M I CA CWS I Renewal Replacement of most corroded and eroded pipes of size 1600mm dia, 1400mm dia, 1000mm dia, 457mm dia and its flanges etc
MTPS I Mill Plant Unit II Removal of accumulated ash from the horizontal portions of the mill inlet hot air ducts at 45mtr level 18mtr level and providing insulation for PA inlet hot air duct to mill for mills 2A to 2F during AOH
MTPS I M I CA CWS I Replacement of existing eroded Ring guard in Cooling Water Pump and its intake screen safety grills cleaning stand painting of hot water header pipe lines sun shield roof structure in Cooling Tower II etc
MTPS I TM I Unit I Inspection and Overhauling of Oil Vapour Extraction Fan assembly Cleaning of strainer assembly and cooling water lines of ESV IV during AOH 2025 26
MTPS I TM Unit III Overhauling and gasket renewing of Valves in Feed Water Main Condensate Heater drain drain water and Auxiliary Steam during the year 2025
MTPS TM Unit I Removal of insulation and providing re insulation to pipe Lines valves Deaerator main flange Gland steam cooler Low pressure heater Flash tanks and its accessories and disposal of waste insulation materials during Unit I Annual overhau
MTPSI TM UNIT I Renewal of piston seal piston rod packing in HP LP Bypass Valves and its Spray valves Actuators including servicing of Oil filters during AOH of 2025 26
MTPS I TM Unit I Removal and Reinsulation of HP IP control Valve area Spindle leak off lines Gland steam pipes of LP front rear in Main Turbine during Annual Maintenance work 2025 26
MTPS I TM Unit IV Complete overhauling and painting of Instrument Air Compressors IAC 4A 4B 4C
MTPS I TM I Unit I Annual Maintenance work in Main Turbine and its Auxiliaries during 2025 26
MTPSI TM Unit I Overhauling of TLOCBPs H2CBPs Hydrazine Dozing Pumps Phosphate Dozing Pumps and Heater drip Pumps during AOH of 2025 26
MTPS I Mill Plant AC Plant Unit I AOH 2025 26 Air Washer System Epoxy painting of blowers discharge duct spray system replacement of damaged duct area and renewal of bellows W type eliminator chemical cleaning Overhauling the AWCW Pumps
MTPS I TM Unit III Cleaning Hydraulic Testing of Lub oil Coolers Working oil coolers Dismantling cleaning and assembling of Suction Strainers of BFPs CEPs Renewal of BFP leak off line and suction discharge flange Gaskets etc
MTPS I TM Carrying out Bullet cleaning by specially designed Phosphor Bronze Bullet shot of LHS RHS of condenser tubes in Unit I condenser during AOH of 2025 26
MTPS I Mill Plant Unit I Fabrication of Vertical shaft lock Nuts and keys for XRP 803 coal mills
MTPS I TM Stage I II Units I II III IV BFPs BFBPs CEPs Voith Hydraulic Couplings and HDPs Preventive Break down Maintenance for a Period of one year from the date of commencement of Work
MTPSI Mill Plant I Complete overhauling of gearbox mechanical face seal assembly worm shaft assembly replacing the worn out bulged insulation cover plate assembly scrapper assembly and worn out flexi coupling etc and Releasing the journal spring assy
MTPS I BM Unit II AOH 2020 Flue gas duct A side Patch up works and other repair works between FG duct 45degree slope end to ESP inlet including cost of materials
MTPS I BM Unit II Boiler pressure parts AOH 2025 Overhauling of Secondary Air Dampers Scanner Air Fans and its damper flap gate Reconditioning of damaged wind Box compartment etc
MTPS I TM Unit I to IV Replacement of 3 Nos existing Service hour Completed emergency replacement of Boiler Feed Pump Cartridge by a Reconditioned Cartridge and commissioning
MTPS I TM Unit II Removal and Re insulation of HP IP control Valve area Spindle leak off lines Gland steam pipes of LP front rear in Main Turbine during Annual Maintenance work 2025 26
MTPS I M I CA CWS I Overhauling of 1600 mm BFV including actuator GB overhauling checking and renewal of Nitrile rubber seal painting of Intake Screen of Cooling water Pumps 2A 2B and 2C etc
MTPS I BM Unit II Boiler Pressure parts COH 2024 Tube thickness survey Water wall buffing providing platform renewal of shroudings and allied works
MTPS I CA CWS I De watering complete cleaning and sludge removal Cleaning with bleaching powder painting the structure of Clarifier II during COH 2024 25
MTPS I BM Unit II Boiler pressure parts COH 2024 Rectification Replacement of defective tubes in burner corner water wall tubes and bends and fin welding at Boiler I st pass area
MTPS I CA CWS I Cooling Tower II Overhauling of Flow Control Valves and including reconditioning of worn out spares during COH 2024 2025 of Unit II
MTPS I - Civil Circle Up keeping of the Central store, Fire Station, Police and security rest room, canteen and auditorium hall, Cooling water pump house, Switch yard, D.G. House, Medical center and Security cum time office for cleaning of Toilet
MTPS I Mill Plant Unit I Removal of accumulated ash from the horizontal portions of the mill inlet hot air duct at 4 5 mtr and 18 mtr level Renewal of eroded worn out Expansion Joint 1A 1B 1C Welding of eroded and worn out portion of hot air
MTPS I BM Unit II Boiler pressure parts AOH 2022 Rectification Replacement of defective Boiler tubes in LTSH Coils and Economizer hanger tubes at Boiler II pass area
Supply of Contact Gauge unit and Contact Gauge for Argonite Cylinder of Argonite Fire suppression System 2 items
MTPS I Mill Plant II Complete overhauling of gearbox Mechanical face seal assembly worm shaft assembly replacing the worn out etc
MTPS I BM Unit IV AOH2023 24 FG Duct A and B sides Renewal of Deflector plates renewal of duct supports renewal of guard plates over the expansion joints renewal of splitter plate and patch welding the eroded portion of the expansion joints
MTPS I TM Carrying out Bullet cleaning by specially designed Phosphor Bronze Bullet shot of LHS RHS of condenser tubes in Unit III condenser during 2025 26
MTPS I TM Unit III Overhauling and renewal of worn out spares and Bearings and commissioning of Heater Drip Pump 3A and 3B during 2025 26
MTPS I TM Unit III Transporting Lifting and reassembling of Vent condenser tube nest modification of 4 syphon line into 6 syphon line and providing 6 flanges in vent condenser by pass line during Unit III 2025 26
MTPS I TM UNIT III Renewal of piston seal and piston rod packing in HP LP Bypass Valves and its Spray valves Actuators including servicing of Oil filters during 2025 26
MTPS I BM Unit III FG duct Dismantling fabrication supply and erection of portion of Flue gas ducts from APH outlet to 45 degree curve end B side during annual overhaul
MTPS 1 BM Unit III AOH 2025 26 Procurement and erection of ID fan casing top portion Impeller wear plate and Casing wear plate Model NDZV 31 SIDOR in ID Fan 3A and 3B and other related works