Loading…
Loading…
1,468 results • Best match
L & T 63A 3 Pole 25 KA Molded Case Circuit Breakers (Mccb) Brand: L & T (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687731024294 dt.22/07/2024)
63A 4 Pole with 35KA Molded case circuit breakers MCCB). Make - Indoasian , Havells, L&t, CG only. [Material required in OEM original packing, firm has to submit purchase proof /OEM authorization c
L & T 32A 3 Pole 25 KA Molded Case Circuit Breakers (Mccb) Brand: L & T (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-511687776013662 dt.11/01/2024)
6ASFUFUSESET-10, 10ASFUFUSESET-20, 16ASFUFUSESET- 30, 32ASFUFUSESET-40, 63ASFUFUSESET-50, 100ASFUFUSESET-60, 125ASFUFUSESET-70, 160ASFUFUSESET-80, 200ASFUFUSESET-90, 250ASFUFUSESET-100, 320ASFUFUSESET-110, 400ASFUFUSESET-120, 16ASFUFUSESET-130, 32ASFUFUSESET-140, 63ASFUFUSESET-150, 100ASFUFUSESET-160, TYPE2DOL0D15-170, TYPE2DOL0D25-180, TYPE2DOL0D37-190, TYPE2DOL0D55-200, TYPE2DOL0D75-210, TYPE2DOL11- 220, TYPE2DOL13-230, TYPE2DOL15-240, TYPE2DOL18D5-250, TYPE2DOL1D1-260, TYPE2DOL1D2- 270, TYPE2DOL1D5-280, TYPE2DOL22-290, TYPE2DOL2D2-300, TYPE2DOL3-310, TYPE2DOL30-320, TYPE2DOL37-330, TYPE2DOL3D7-340, TYPE2DOL4-350, TYPE2DOL45-360, TYPE2DOL55-370, TYPE2DOL5D5-380, TYPE2DOL75-390, TYPE2DOL7D5-400, TYPE2DOL80-410, TYPE2DOL90-420, TYPE2DOL9D3-430, TYPE2RDOL11-440, TYPE2RDOL15-450, TYPE2RDOL1D1-460, TYPE2RDOL1D3- 470, TYPE2RDOL1D5-480, TYPE2RDOL2D2-490, TYPE2RDOL3D7-500, TYPE2RDOL75-510, HEATER100A- 520, HEATER125A-530, HEATER016A-540, HEATER032A- 550, HEATER063A-560, EL7422623268-570, EL7422623276-580, EL7422627018-590, EL7422627328- 600, EL7422627077-610, EL7423850004-620, EL7423850012-630, EL7423850020-640, EL7423850039- 650, EL7423850047-660, EL7423850055-670, EL7423873055-680, EL7423873065-690, EL7423873066- 700, EL7422813059-710, EL7422811056-720, EL7422801018-730, EL7422801026-740, EL7422000058- 750, EL7422000031-760, EL7422000023-770, EL74210006A1-780, EL7420900442-790, EL7420900450- 800, EL7420900400-810, EL7420900418-820, EL7420900388-830, EL7420813060-840, EL7420813061- 850, EL7420813027-860, EL7420831025-870, EL7420831026-880, EL7420811024-890, EL7420811040- 900, EL7420811075-910
PROVN OF PARKING SHED WITH HARD STANDING OFFRS JCO OR AT ASRI BLDG AND PROVN OF LT RING MAIN RMU SYSTEM TO KAKUL BLOCK AND BAREILLY BLOCK AND CONNECTD WORKS AT ASC CENTRE AND COLLEPROVN OF PARKING SHED WITH HARD STANDING OFFRS JCO OR AT ASR
Supply, Installation, Testing and Commissioning of ACB Panel, Cables, Earthing etc including allied works for shifting the loads connected to 800 KVA And 1000 KVA Transformer to 2000 KVA Transformer and removal of unused Panels at Bangalore Terminal
Outsourcing of photocopying work of CBI ACB Bangalore
SPECIAL REPAIR/REPLACEMENT OF OLD UG LT CABLES, LT PANELS, LOOP IN LOOP OUT BOXES IN TECH AREA OF AFS YELAHANKA
Providing Skilled Technical Manpower for Operation along with Annual Maintenance of Inetrnal & External Electrical Installations, Online UPS systems, Maintenance to 750 KVA & 1250 KVA DG set with fuel, Maintenance of 2x1600KVA HT Sub-Station with ... HT-LT Control Panels , ...
SUPPLY OF PHOENIX MAKE POWER SUPPLY MODULES FOR UNIT 1 TO 3 TURBINE/CPPDCS CONTROL PANELS AT NTPC KUDGI STPS
Providing additional 1x10MVA 110/11kV Power Transformer along with 11kV Switchgear at 110KV S/S Morab in Raibag Taluk, Belgavi District including supply of equipments / materials, erection, civil works, testing and commissioning on Partial Turn Key Basis.
SPECIAL REPAIR REPLACEMENT OF UG CABLE ALONG WITH ALLIED SERVICE AND CONVERSION TO TWO FOUR POLE STRUCTURE TO HT 11 KVA VCB PANEL AT CQAL UNDER GE NORTH BANGALORE
Auxiliary Contactor for Pantograph and VCB (Pos. no. 130.1, 136.4) as per CLW spec no. CLW/ES/3/0040, Alt A or Latest, Type Ref. LC1D09FD Accepted Make: SCHNEIDER
Transformer Oil Filtration, Transformer Oil Test, OLTC Oil Testing, Supply of Transforme, Siemens 7SJ662 Relay Test, Siemens 7SR242 Relay Test, Siemens 7SJ661 Relay Test, Siemens 7SA610 Relay test, TCS Relay Testing, Testing Motor Protection LTMR, ... A ACB Test ... A ACB Test ... A ACB Test ... kV VCB Test ... kV VCB Test ...
Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) - Repair of control panel of Boat Davits for 6 5m and 7 3m; Repair of control panel of Boat Davits for 6 5m and 7 3m; Service Provider
REPAIR REPLACEMENT OF UNSERVICEABLE SUBMAIN WIRING POINT WIRING SWITCHES SOCKETS EARTHING FOR BUILDING UNSERVICEABLE DB LT FEEDER BOX MCBs BUILDING SERCURITY LIGHT INDUSTRIAL SOCKETS MCCB ISOLATOR GARDEN LIGHTS INCLUDING WORKS AT DFRL RESIDENTIA
REPAIR REPLACEMENT OF UNSERVICEABLE SUBMAIN WIRING POINT WIRING SWITCHES SOCKETS AND EARTHING FOR BUILDING UNSERVICEABLE DISTRIBUTION BOARDS LT FEEDER BOX MCBs BUILDING SECURITY LIGHT INDUSTRIAL SOCKETS MCCB ISOLATORS GARDEN LIGHTS INCLUDING ALLIED W
Supply of moulded case circuit breaker (MCCB) confirming to IS/IEC 60947-2, 4 pole, rated current 250 amps, rated voltage : 415 v, 50 hz, breaking capacity : 50 KA, thermal magnetic release, adjustab
C&S ELECTRIC 4 Pole 400A Moulded Case Circuit Breakers (MCCB) with Breaking Capacity - 50 KA Brand: C&S ELECTRIC (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-5116877
"MCCB 100 Amp triple pole, 415 volt, 50 Hz with steel sheet enclosure of 1.2 mm thickness duly pretreated stove enameled/powder Coated. Breaking capacity 35 KA with Tumbler Knob and suitable extension
Supply and testing of 125 AMP, 4 Pole MCCB, Breaking capacity - 36 KA, Rated Operational Voltage - 550V or higher, 50Hz, 3 Phase AC, Rated insulation voltage - 800V AC or higher, capable to withstand
C&S ELECTRIC 4 Pole 630A Moulded Case Circuit Breakers (MCCB) with Breaking Capacity - 50 KA Brand: C&S ELECTRIC (Detailed Description/Specification as per Product # 1 of GeM Contract No. GEMC-5116877
Switch Fuse Unit (Q3), distribution or control board enclosures ( Distribution board for MCBs) (Q3)
REPAIR / REPLACEMENT OF LT UG CABLE, LT SWITCHGEAR, CABLE ROUTE INDICATORS, DISTRIBUTION LAYOUTS, LED SIGN BOARDS, CABLE DETECTION AND CONNECTED WORKS AT HQ JL WING, ACHARYA ENCLAVE, HARSHAN ENCLAVE I AND II, MOHIT ENCLAVE, VIRK ENCLAVE, CDO WING
Repairs to faulty Transformer, repairs and servicing of HT LT Panels switchgears at 100 KVA Transformer Sub Station at TE RAJAJINAGAR Bangalore
MAINTENANCE, REPAIRS TO HT 11 KV PANELS, TRANSFORMERS, HT VCB/OCBs, LT DISTRIBUTION SYSTEM, EARTHING AT PHASE-I AND FAR FLUNG AREA OF GE (I) R AND D (WEST) BENGALURU
POH KIT FOR SINGLE BOTTLE VCB TYPE BVAC 25.10M07 [NEW] OF M/S BTIPL CONSISTING OF 20 ITEMS AS PER attached ANNEXURE. Kit No. 3EYC-400262-R1 (Part No. VPOH)
distribution or control board enclosures ( Distribution board for MCBs) Distribution Or Control Board Enclosures ( Distribution Board For MCBs) ( 4 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values ... MCB distribution board for ...
MOULDED CASE CIRCUIT BREAKER (MCCB) CONFIRMING TO IS/IEC 60947-2 , 4 POLE RATED CURRENT 125 A , RATED VOLTAGE 415 V, 50 HZ , RATED INSULATION VOLTAGE 800V , RATED IMPULSE WITHSTAND VOLTAGE 6 KV, OPERA
Moulded case circuit breaker (MCCB), 3 pole, rated current-32 amps, breaking capacity 30 kA, Adjustable type, conforming to IS 13947-2 IEC 60947-2. Suitable for Hot buffet car and conforming to EDTS
VTPN MCCB 250A DB-Double Door, 12 Way, Modules optium F2+36 , Protection : IP 43, Insulated busbar assembly, Door Earthing, suitable for MCCBs upto 250A with ISI Mark similar to indoasian Cat no.81
VFD CUM PANEL-CPM-504 B, VFD-55KW FOR CHILLER MOTOR BG-1030 A/B/C, STARTER PANEL, WEATHERPROOF, ATS CUBICAL CONTROL PANEL- 90HP, 415V, 3 PHASE, 50Hz, STARTER PANEL, WEATHERPROOF, ATS CUBICAL CONTROL PANEL- 200HP, 415V, 3 PHASE, 50Hz
Submercible dewatering sump pump in std aluminium construction along with motor. Rating 50Hp, Electrical indoor control panel for 50 Hp pump, Submercible dewatering sump pump in std aluminium construction along with motor. Rating 1.5Hp, Electrical ... indoor control panel for
EL7423001010, EL7423021010, EL7423041011, EL7423001028, EL7423011023, EL7423031024, EL7423001036, EL7423001037, EL7423001038, EL7423001052, EL7423011058, EL7423031059, EL7423051050, EL7423041054, EL7423001044, EL7423011040, EL7423021029, EL7423041020, EL7423021052
SITC of Electrical Panels, SITC of Armoured Cables, Admin Porta Cabin, Secuirty Porta Cabin, 58.5 KVA DG set
Replacement of existing Old/ Outlived/ Unserviceable APFC Panels with new APFC panels, Enhancement of switchgear of LT Essential and Non- Essential Panels, providing Synchronization Panels for the existing 02 No. DG sets in the substation at NIUM, Kottigepalya, Bangalore.
Providing additional 1X10 MVA at 110/11 kV power transfromer along with switchgear at 110 kV S/S Honaga in Belagavi taluka, Belagavi districtIncluding supply of equipments / materials, erection, civil works, testing and commissioning on Partial Turn Key Basis.
Providing additional 1X10 MVA at 110/11 kV power transfromer along with switchgear at 110 kV S/S Khanapur in Khanapur taluka, Belagavi districtIncluding supply of equipments / materials, erection, civil works, testing and commissioning on Partial Turn Key Basis.
Installation of Multi Parameter Controller with integrated sensors for measuring COD, BOD, TSS, PH, DO, ORP, and Temperature, loT-enabled control panel for MBR systems, designed to monitor key parameters like pump status, blower operation, and sensor data (pH, DO, ORP, etc.) in real time and Tertiary treatment for 4 MLD at 8MLD STP Halmaddi Dandeli(Others)
Contactor 3 pole, 24V DC, 50 amps suitable for starter battery charging control panel for use in DG set equipped in LHB power car as per EDTS-116 Rev-A or Lat. Make as per BOM of EDTS -116 Rev-A of ABB cat no. AF50-30-00, 24V DC or equivalent of Schneider / Siemens / C&S / Eaton.
IOH KIT FOR SINGLE BOTTLE VCB OF M/S BTIPL TYPE BVAC 25.10 M07 [NEW] IOH KIT NO. 3EYC-400261 R1 [ PART NO. VIOH] CONSISTING OF 14 ITEMS AS PER ANNEXURE
Providing new UG cable and electrical panel for Civil Engineering Department building, in NITK
REPAIR REPLACEMENT OF UNSERVICEABLE SUBMAIN WIRING POINT WIRING SWITCHES SOCKETS EARTHING FOR BUILDING UNSERVICEABLE DB LT FEEDER BOX MCBs BUILDING SERCURITY LIGHT INDUSTRIAL SOCKETS MCCB ISOLATOR GARDEN LIGHTS INCLUDING REPAIR TO ROADS AT DFRL RESID
REPAIR REPLACEMENT WIRING LIGHT FITTINGS MCB, MCCB, CEILING LIGHT AND CONNECTED ITEMS AT LAXMI TEK 1 AND 2, MOHIT ENCLAVE. NAGZEERA LINE, HARDING LINE, GE OFFICE COMPLEX, ARO BELGAUM AND ROHIDESHWAR CAMP UNDER GE BELGAUM.
MCCB 3 pole 415V AC 200A Breaking capacity 36KA/35KA or Disney DN2- 250D 200A 3P TM (Mug 6-10) 36 KA Make -L&T, Siemanes, Havells. Acceptred Brand: L&T OR SIEMENS OR HAVELLS
Moulded case circuit breaker (MCCB), 3 pole, rated current-32 amps,breaking capacity 30 kA, Adjustable type, confirming to IS 13947-2 IEC 60947-2. Suitable for Hot buffet car and confirming to EDTS 11
Moulded case circuit breaker (MCCB), 3 pole rated current 32 amps, breaking capacity 30 kA, Adjustable type conforming to IS 13947-2 IEC 60947-2 suitable for LHB Hot Buffet Car and conforming to EDTS
Supply of ISI Marked, 200 Amps 4 Pole, MCCB having Specifications, 415 V AC, 50 Hz, Rated Conditional Short-Circuit Current: 25 KA, with metal enclosure, IP 20, Frame: F2, conforming to IS/IEC: 60947-
Supply of ISI Marked, 250 Amps 4 Pole, MCCB having Specifications, 415 V AC, 50 Hz, Rated Conditional Short-Circuit Current: 25 KA, with metal enclosure, IP 20, Frame: F2, conforming to IS/IEC: 60947-
VACUUM CIRCUIT BREAKER (SINGLE BOTTLE) AS PER CLW SPECN. NO. CLW/ES/C- 47/ALTERATION-I WITH MATCHING ACCESSORIES SUITABLE FOR 3-PHASE WAP7/WAG9HC LOCOMOTIVES. EACH SET CONSISTS OF - (1) VCB ASSEMBLED - 1 NO. (2) MALE CONNECTOR 1/2 X 3/8 - 03 NOS. (3) ... IN VCB ) ...