diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 25 (or higher) No of Phase - Single phase, Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Electronic (or higher) Class of governer A1 A1 (or higher) Number of cylinders (nos) 3 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500, 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 25 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 76.73 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual, AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6, 1.8, 2, 1.2 Higher is better Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/4 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986, in respect of noise and emission norms, as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation With Installation, Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vijay Prakash Meena 326001, Government Girls College Opposite Kendriya Vidyalaya, Patan Road Jhalawar 1 15
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 25 25 (or higher) No of Phase - Single phase, Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Electronic Electronic (or higher) Class of governer A1 A1 (or higher) Number of cylinders (nos) 3 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500, 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 25 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 76.73 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual, AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6, 1.8, 2, 1.2 Higher is better Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - 2/4 Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986, in respect of noise and emission norms, as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation With Installation, Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Vijay Prakash Meena 326001, Government Girls College Opposite Kendriya Vidyalaya, Patan Road Jhalawar 1 15
64 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.