Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
No organisation data
Try another outcome or period.
No state data
Try another outcome or period.
solar water heating system Solar Water Heating System ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment N/A BIS Approved Yes Yes, No If Yes, Mention CM/L No. otherwise write NA 6235562 N/A Model Number of Solar Water Heater System RI-1000 LPD WO HE WR N/A Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with out Heat Exchanger Solar water Heating System with Heat Exchanger, Solar water Heating System with out Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C N/A Rated Capacity in Litres per Day (LPD) 1000 100, 200, 300, 500, 1000, 1500, 2000 Warranty (Years) 1 Year 1 Year, 2 Years, 3 Years, 4 Years, 5 Years, 6 Years, 7 Years, 8 Years CONSTRUCTIONAL Aperture area of 18.0 1.8, 2.0, 3.6, 4.0, 5.4, 6.0, 1/6 collector, Sq. Meteres (Sq Meter) 9.0, 10.0, 18.0, 20.0 Electrical Heater ( Back up ) Capacity (kw) 6 2, 3, 4, 6, 9 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) NA 5.0, NA Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes N/A Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum, Toughened Glass and Anticorrosive Solar Glass with minimum thickness 3.2 mm Solar Transmittance for cover plate at normal Incidence (%) 82 N/A Material for Collector Box Aluminium Aluminium, CRCA Numbers of collectors 8 N/A Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based N/A Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based N/A Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based N/A Thickness of Sheet for entire body >/= 1.0 mm for aluminium based N/A CRCA Material Thickness >/= 0.91 mm for CRCA N/A Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa N/A Number of absorber sheets per collector 1 N/A 2/6 Numbers of Header Tubes 2 N/A Numbers of Riser Tubes 9 N/A Diameter of Header Tube (mm) >/= 24.5 mm N/A Diameter of riser tube (in mm) >/= 11.5 mm N/A Thickness of Header Tube (mm) >/=0.71 N/A Thickness of Riser Tube (mm) >/= 0.56 mm N/A Material of Riser Header for Absorber Copper Only N/A Distanace Between Risers from center to center (mm) >/= 120 (mm) N/A Material of sheet for absorber Copper Copper, Aluminium Collector Box Insulation Back and sides N/A Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km N/A Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km N/A Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes N/A Material for Hot water storage Tank Cold Rolled Steel (other material as per MNRE Notification year2011) SS304, SS 316, Cold Rolled Steel (other material as per MNRE Notification year2011), Mild Steel, any other Material with anticorrosive coating for hard water with chlroine components Name the Material if choose others EPDM N/A Non Pressure Type Hot water Storage Tank Yes N/A Position of Hot water tank Horizontal N/A Thickness of sheet of Hot water tank (mm) 1.2 N/A 3/6 Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 N/A Hot water Welding TIG N/A Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint N/A Thickness of Coating (micron) 70 N/A Tank stand Material Mild Steel N/A Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes N/A Type of Heat Exchanger cage Type N/A Material for Heat Exchanger Stainless steel Copper, Stainless steel Thickness of tube of heat Exchanger, Minimum 22 SWG Yes N/A Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity N/A Numbers of Electrical Heaters ( Back Up Type ) provided 3 2, 5 Collector Stand Material Mild steel N/A Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes N/A System Interconnecting Pipes material G.I Pipes as per IS: 1239 N/A if other mention the Material for interconnecting pipes NA N/A Size of interconnecting Pipes (mm) 25.4 N/A Tank test Pressure (bar) 1 N/A System Working Pressure (Bar) 1 N/A 4/6 Inlet and Outlet Valve Yes N/A Temp Gauge( for Hot Water ) Yes N/A Gun Metal Strainer ( for Cold Water ) Yes N/A Water Meter Yes N/A Gasket for Flanges 3 mm thick gasket of neoprene N/A Electrical Back up Control panel Yes N/A Make of Control Panel L&T N/A if others, mention the make of Control Panel L&T N/A Weight of solar water heater system (kg) 440 N/A CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools, Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes N/A Test Report No. MKU/RTC/16/045 N/A Test Report Date 14.10.2017 N/A Name of the Lab MADURAI KAMARAJ UNIVERSITY N/A Address of the Lab MADURAI, TAMILNADU N/A Availability of Schematic Drawing Yes N/A Instruction Manual for installation, Repair and maintanance Yes N/A test teat1 true N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prem prakash 282002, KENDRALAY, BLOCK 63/4 FIRST FLOOR, SANJAY PLACE, AGRA PIN 10 20 5/6 NO.282002. EMD Required No ePBG Required No
solar water heating system Solar Water Heating System ( 10 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Conformity to standards for Solar water Heating System -Code for Acceptance IS:12976:1990 with latest amendment N/A BIS Approved Yes Yes, No If Yes, Mention CM/L No. otherwise write NA 6235562 N/A Model Number of Solar Water Heater System RI-1000 LPD WO HE WR N/A Solar water Heating System Compatibility with Heat Exchange Solar water Heating System with out Heat Exchanger Solar water Heating System with Heat Exchanger, Solar water Heating System with out Heat Exchanger Region Type 2 Warm (Areas where ambient temp. is moderate and do not normally below 5 Deg. C N/A Rated Capacity in Litres per Day (LPD) 1000 100, 200, 300, 500, 1000, 1500, 2000 Warranty (Years) 1 Year 1 Year, 2 Years, 3 Years, 4 Years, 5 Years, 6 Years, 7 Years, 8 Years CONSTRUCTIONAL Aperture area of 18.0 1.8, 2.0, 3.6, 4.0, 5.4, 6.0, 1/6 collector, Sq. Meteres (Sq Meter) 9.0, 10.0, 18.0, 20.0 Electrical Heater ( Back up ) Capacity (kw) 6 2, 3, 4, 6, 9 Capacity of Make up tank( SWHS with Heat Exchanger only ) (Ltrs) NA 5.0, NA Solar Flat Plate shall be BIS marked and as per IS :12933/2003 with amendment 1 to 3 Yes N/A Type of Cover Plate conforming to IS 12933/2003 Made up of Toughened Glass with thickness 4.00 mm minimum Made up of Toughened Glass with thickness 4.00 mm minimum, Toughened Glass and Anticorrosive Solar Glass with minimum thickness 3.2 mm Solar Transmittance for cover plate at normal Incidence (%) 82 N/A Material for Collector Box Aluminium Aluminium, CRCA Numbers of collectors 8 N/A Minimum Channel Section Thickness for sides ( For Al based) >/= 1.4 mm for aluminium based N/A Minimum Thickness of Sheet for Bottom ( For Al based) >/= 0.45 mm for aluminium based N/A Minimum Thickness of Sheet used as Support for Glass retaining ( For Al based) >/= 1.2 mm for aluminium based N/A Thickness of Sheet for entire body >/= 1.0 mm for aluminium based N/A CRCA Material Thickness >/= 0.91 mm for CRCA N/A Riser and Header assembly designed for working pressure Riser and Header assembly designed for working pressure 24.5 k pa tested for leakage at a minimum hydraulic pressure of 490 K pa N/A Number of absorber sheets per collector 1 N/A 2/6 Numbers of Header Tubes 2 N/A Numbers of Riser Tubes 9 N/A Diameter of Header Tube (mm) >/= 24.5 mm N/A Diameter of riser tube (in mm) >/= 11.5 mm N/A Thickness of Header Tube (mm) >/=0.71 N/A Thickness of Riser Tube (mm) >/= 0.56 mm N/A Material of Riser Header for Absorber Copper Only N/A Distanace Between Risers from center to center (mm) >/= 120 (mm) N/A Material of sheet for absorber Copper Copper, Aluminium Collector Box Insulation Back and sides N/A Thermal Resistance of Insulation in Square Degree for Back Face >/=0.96 W/Km N/A Thermal Resistance of Insulation in Square Degree for Side Face >/=0.47 W/Km N/A Gasket and Grommets shall confirm to IS 12933/2003 with latest amdt Yes N/A Material for Hot water storage Tank Cold Rolled Steel (other material as per MNRE Notification year2011) SS304, SS 316, Cold Rolled Steel (other material as per MNRE Notification year2011), Mild Steel, any other Material with anticorrosive coating for hard water with chlroine components Name the Material if choose others EPDM N/A Non Pressure Type Hot water Storage Tank Yes N/A Position of Hot water tank Horizontal N/A Thickness of sheet of Hot water tank (mm) 1.2 N/A 3/6 Hot water Tank Insulation Density ( High density PUF insulation for 32 kg meter cube or higher density (mm) >/=40 N/A Hot water Welding TIG N/A Coating Material for Hot water tank Polyster Epoxy Plus Balck Epoxy based Paint N/A Thickness of Coating (micron) 70 N/A Tank stand Material Mild Steel N/A Size of Tank Stand (L x W x H ) Must be Greater Than 38 x 38 x 4 (mm3) Yes N/A Type of Heat Exchanger cage Type N/A Material for Heat Exchanger Stainless steel Copper, Stainless steel Thickness of tube of heat Exchanger, Minimum 22 SWG Yes N/A Heat Transfer Rate for heat Exchanger Must be greater than 0.24 sq meter per 100 LPD capacity N/A Numbers of Electrical Heaters ( Back Up Type ) provided 3 2, 5 Collector Stand Material Mild steel N/A Size of Collector Tank Stand (L x W x H ) Must be Greater Than 38 x38 x 4 (mm3) Yes N/A System Interconnecting Pipes material G.I Pipes as per IS: 1239 N/A if other mention the Material for interconnecting pipes NA N/A Size of interconnecting Pipes (mm) 25.4 N/A Tank test Pressure (bar) 1 N/A System Working Pressure (Bar) 1 N/A 4/6 Inlet and Outlet Valve Yes N/A Temp Gauge( for Hot Water ) Yes N/A Gun Metal Strainer ( for Cold Water ) Yes N/A Water Meter Yes N/A Gasket for Flanges 3 mm thick gasket of neoprene N/A Electrical Back up Control panel Yes N/A Make of Control Panel L&T N/A if others, mention the make of Control Panel L&T N/A Weight of solar water heater system (kg) 440 N/A CERTIFICATIONS Availability of Test Report as per IS : 6893-6 (1985) used for purcahse specification for Machine Tools, Part 6 Bench/Pillar type Drill Machine with latest amndmt.from Central Govt./NABL/ILAC acredited lab to prove confirmity to specification yes N/A Test Report No. MKU/RTC/16/045 N/A Test Report Date 14.10.2017 N/A Name of the Lab MADURAI KAMARAJ UNIVERSITY N/A Address of the Lab MADURAI, TAMILNADU N/A Availability of Schematic Drawing Yes N/A Instruction Manual for installation, Repair and maintanance Yes N/A test teat1 true N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Prem prakash 282002, KENDRALAY, BLOCK 63/4 FIRST FLOOR, SANJAY PLACE, AGRA PIN 10 20 5/6 NO.282002. EMD Required No ePBG Required No
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.