Online UPS 5 KVA for Critical Infrastructures Online UPS 5 KVA For Critical Infrastructures ( 3 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Online UPS should support for critical infrastructures such as Data Centres, Network operating centres, Security operation centres, State and District centres, Command and Control centre etc., across the Country to provide impetus to the e- Governnance services e.g.Public food distribution, e Way bill, Counseling, e-Office, IVFRT etc., services under Digital India Programme Yes * On Line UPS Capacity/Battery back up time at full load/Minimum VAH 5 KVA/60 Minutes/8193 VAH 5 KVA/60 Minutes/8193 VAH 1/8 Inverter Technology PWM with IGBT, double conversion * Isolation transformer: Galvanic Isolation through inbuilt transformer at UPS output side Yes * Output wave form Pure sine wave * Country of origin for Inverter India * Noise level (1 meter distance from UPS) </= 55 dB * UPS shall have cold start facility Yes * Type of cool Air cooled * Parallel load sharing redundant operation with all accessories No * Installation and commissioning Yes Yes INPUT Input AC Single Phase * In put Voltage Range 160 V to AC to 270 V AC * Input frequency range 50 Hz +/-6% Hz * Input power factor at full output load leading to unity with active power factor correction (APFC) >/=0.90 * Distortion (current) Less than 10% * UPS shall have DG set compatibility Yes * OUTPUT Out put voltage 230 V AC +/-1% Single Phase * Voltage regulation (Steady state) at No load to full load, 0.6 lag to Unity PF, During entire back up time, Complete input voltage range +/-1% * Frequency 50 Hz +/-0.5 % Hz * CONSTRUCTION Minimum thickness (in mm) of M.S.Sheet Enclosure for UPS duly powder coated 1.0 * UPS shall be free from Yes * 2/8 workmanship defects, sharp edges, nicks, scratches, burst, etc. All fasteners shall be fixed properly. The equipment shall be complete with all parts and all parts shall be functional UPS enclosure's degree of protection as per IS:13947 (Part 1)/1993 latest IP21 * UPS shall have switches for: Mains ON/OFF MCB, Battery ON/OFF MCB/Fuse, Inverter push button with reset Yes * Standard quality Out put terminals shall be provided for output connection Yes * UPS shall have static and manual by pass facility Yes * UPS shall be supplied with required rated power cable (Copper) 5 Meters * Total Harmonic Distrotion (THD) for 100% linear load < 3% * Total Harmonic Distrotion (THD) for 100% non-linear load < 5% * Operating temeprature 0 deg C to 40 deg C * Humidity Upto 95% non- condensing * Crest factor on full non- linear load Not less than 3:1 * Over all efficiency on rated full load of 0.8 PF and 230 Volt, 50 Hz AC output >/=80% * Inverter efficiency on rated full load of 0.8 PF and 230 Volt, 50 Hz AC output >/=85% * UPS shall withstand Over load capacity - for 2 Minutes * 3/8 110% UPS shall withstand Over load capacity - 125% for 30 seconds * Load power factor 0.8 lagging to unity Yes * Transient response time (for 100% load change, output must remain within +/-4% and recovery) </-20 milli seconds * PROTECTION Short circuit protection Yes * Over load protection Yes * Over temperature protection Yes * In put low/high voltage control Yes * DC low/high voltage trip Yes * BATTERY Battery shall conforming to JISC:8702(Pt.I, II&III) latest Yes * Battery type SMF VRLA * Country of origin for Battery India * Battery recharge time (after complete discharge to 90% charge) and charge rating: Battery recharge time to 90% charge after 100% DoD 8 to 10 hours * Battery charger should be capable to charge battery on C10 rating Yes * VAH tolerance -1% of the defined capacity * Battery cutoff voltage during back up Not less than 10.5 V * More than two battery banks should not be used in parallel in any configuration Yes * Batteries shall supply with With rack With rack, With moveable trolley Meters and Indicators UPS shall have LCD meter to measure and Yes * 4/8 monitor input votlage, output voltage, output current/load level in %, DC current/DC level in %, DC voltage, input and output frequency UPS shall have indicators for Mains on, Load on battery, Inverter, Battery level, Load level, Inverter over load Yes * UPS shall have audible alaram for over temperature, mains failure, battery low, inverter overload Yes * Management port: Preferably SNMP based with management Software No Yes, No WARRANTY AND SERVICES Warranty for UPS (on site comprehensive warranty) (in years) 3 3, 4, 5 Warranty for battery (replacement warranty) (in years) 2 2, 3 After sales and complaint service within 48 hours * PAN India service support on 24 x 7 basis Yes * AMC support available after 5 year warranty Yes * Quarterly preventive maintenance available No * Manufacturer shall provide and support for instllation, commissioning, spares, technical support all over India Yes * Availability of spares in close proximity (Spares should be easily available close to the site) Yes * CERTIFICATIONS ISO Certification Yes * CE Certification and Yes Yes, No 5/8 marking Damp Heat Test : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C, two cycles of (12+12) hours each 2007) Yes * Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) at 55 degree C for 16 hrs Yes * Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes * Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable as on date Yes * As per Meity (Government of India) guidelines storage battery shall have valid BIS CRS certifications as applicable as on date Yes * All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 E Dhandapani 605013, District Registrar Office complex, Kamaraj 3 15 6/8 Salai, Saram Puducherry
Loading…