diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 10 3.5, 5, 7.5, 10, 15, 20, 25, 3 0, 40, 62.5, 82.5, 100, 125, 160, 180, 200, 250, 320, 380, 400, 500, 600, 750, 5 0, 140 No of Phase - Single phase, Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - Type of Engine cooling Air Cooled Air Cooled, Liquid Cooled Type of governer Mechanical Mechanical, Electronic Class of governer A2 A0, A1, A2 Number of cylinders (nos) 2 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500, 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 10 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 86.9 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual, AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6, 1.8, 2, 1.2 Thickness of Foam 20 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986, in respect of noise and emission norms, as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 1 Installation & Commissioning Without Installation With Installation, Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashish 135001, Member Secretary District Information Technology Society 317-318 Second Floor Mini Secretariat Yamunananagar 1 15 EMD Required No ePBG Required No
Loading…