digital earth resistance meter Experience with Gov. Required 5 Year (s) Digital Earth Resistance Meter ( 30 ) Technical Specifications Specification Specification Name Values Allowed Values FEATURES Display type 3½ digit LCD display 3½ digit LCD display, 4 digit LCD display Measurable Earth resistance range selection Range selection through a switch Auto ranging, Range selection through a switch Method for resistance measurement 4-pole 2-pole, 3-pole, 4-pole Counts 4000 2000, 3000, 4000, 6000, 10000 Number of the stakes 4 - Material of the stakes M.S. Spikes - Length of the Stakes 18 - Diameter of the Stakes 0.5 - Number of the Test Leads 2 - Length of the Test Leads 20 - Number of Test Leads with Clamps 2 - Length of Test Leads with Clamps 20 - 1/4 OTHER FEATURES Internal Memory (Number of record) 0 - External memory Through USB - Interface USB - Minimum Open Circuit Output voltage 100 - Over range indication Available - Stakeless test(Clamp On) false MEASUREMENTS Number of Measurable Range 2 - Measurable Ranges (Ohm) 0.01 to 19.99, 1 to 1999 - Measurable Earth resistance resolution (Ohm) 0.01 - Measurable Earth resistance accuracy ±6 % ±1 count - Facility to Measure Earth Voltage true - If Yes, Measurable Earth Voltage range 0 - If Yes, Measurable Earth Voltage accuracy 0 - If Yes, Measurable Earth Voltage resolution 0 - Other features NA - GENERIC Weight of the tester 575 - Dimensions (cm x cm x cm) 172 x 98 x 38 - POWER REQUIREMENTS Type of Battery Rechargeable - if rechargeable, then chemistry of the battery Ni-MH - if Non-rechargeable, then size of the battery cell AA - Number of non- rechargeable the battery/cell NA - Voltage of rechargeable Battery 10 - Capacity of rechargeable battery (milliamperehour) 8000 - 2/4 Suitable charger adaptor provided yes - Battery backup time 8 - Low battery indication Available - ACCESSORIES Details of All connecting Cables and accessories to be supplied along with the tester POWER CORD, Earth Testing KiT - TEST REPORT DETAILS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hours at a temperature of 55 degree C in accordance with IS:9000/part-3/sec tion-5/1977 latest false - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 latest false - conformity to Cold test at 0 degree C for four hours as per IS: 9000( Part 2/section 4) latest false - Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove confromity to the specification false - Test Report Number and date for the specification test - - Name and address of the Lab for the specification test - - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Koushalendra Kumar 828401, Office of the Chief Crew Controller, Near TRS Gomoh, East Central 30 15 3/4 Railway Gomoh EMD Required No ePBG Required No
Loading…