NRV Class 300 Diameter 300, NRV Class 150 Diameter 300, NRV Class 150 Diameter 350, NRV Class 150 Diameter 400, NRV Class 300 Diameter 450, Sluice Valve Class 300 Diameter 300, Sluice Valve Class 150 Diameter 350, Sluice Valve Class 300 Diameter 450, Air Vessel 2000 L with bladder system of gaspreset of 100 kPa, Air Vessel 2500 L with bladder system of gaspreset of 100 kPa, Air Vessel 3500 L with bladder system of gaspreset of 100 kPa, Providing And Fixing 300 mm Flow Meter, Providing And Fixing 350 mm Flow Meter, Providing And Fixing 450 mm Flow Meter
Main LT Panel Indoor type with FP AI high safety mode technology, APFC Capacitor Panel 1250 KVAR INDOOR TYPE WITH ALUMINIUM TP, VACUUM CIRCUIT BREAKER PANEL 11 KVA 800 AMP and VCB PANEL, TRANSFORMER 3500 KVA INPUT VOLTAGE 11 KV OUTPUT VOLTAGE 415 V, Earthing Arrangement Copper plate earthing with 50 kg of chemical earthing Transformer - 3500 KVA TECHNICAL SPECIFICATION- 1- Capacity : 3500 kVA, 2- Input Voltage : 11 KV, 3- Output Voltage : 415 V, 4- Number of Phase : 3 Phase 5- Applicable Standard : Standard, 6- Number of Winding : 02 Nos, 7- Installation Type : Outdoor, 8- Cooling Type : ONAN, 9- Terminal Arrangement : Bare, Bushing for HV Side & 10- Cable Box for LV Side., 11- Vector Group : Dyn 11, 12- Ambient Temperature : 50° C, 13- Temperature Rise of Oil : 40° C, 14- Temperature Rise of Winding : 45°C, 15- Impedance : 6.25% (Subject to +/-10% Tolerance), 16- Transformer Oil : "A Grade" tested & certified as per IS:335 Standard., 17- No Load Losses : As per IS Standard, 18- Full Load Losses : As per IS Standard, 19- Copper : Pure Electrolytic Grade, 20- Tapping Mode 01 Nos - Rotary Type Off Circuit Tap Changer (OCTC) with Locking Arrangement & Tap Indication., 21- Basic Insulation Leve for HV : 75 KV peak/28 KV RMS, 22- Basic Insulation Level for LV : -/3 KV RMS, 23- Tapping Range +5% to -5% in Steps of 2.5% by Off Circuit Tap Changer (OCTC)., (A) EARTHING ARRANGEMENT (1) Copper Plate Earthing 600x600x6 mm with 50 Kg of Chemical Compound depth around 10 Meter with Testing Pit. (2) GI Plate Earthing 600x600x6 mm with 50 Kg of Chemical Compound depth around 4 Meter with Testing Pit. (3) COPPER STRIPS 50*6 (4) GI STRIPS 50*6 MAKE PREMIUM, (B) CABLES AND ACCESSORIES (1) 3 C x 240 Sqmm AL Armoured HT Cable (2) JOINT KIT (3) 3.5 C x 400 Sqmm AL Bid Number : GEM/2025/B/6768705 Dated : 17-10-2025 Bid Document 1/19
NRV Class 300 Diameter 300, NRV Class 150 Diameter 300, NRV Class 150 Diameter 350, NRV Class 150 Diameter 400, NRV Class 300 Diameter 450, Sluice Valve Class 300 Diameter 300, Sluice Valve Class 150 Diameter 350, Sluice Valve Class 300 Diameter 450, Air Vessel 2000 L with bladder system of gaspreset of 100 kPa, Air Vessel 2500 L with bladder system of gaspreset of 100 kPa, Air Vessel 3500 L with bladder system of gaspreset of 100 kPa, Providing And Fixing 300 mm Flow Meter, Providing And Fixing 350 mm Flow Meter, Providing And Fixing 450 mm Flow Meter
Main LT Panel Indoor type with FP AI high safety mode technology, APFC Capacitor Panel 1250 KVAR INDOOR TYPE WITH ALUMINIUM TP, VACUUM CIRCUIT BREAKER PANEL 11 KVA 800 AMP and VCB PANEL, TRANSFORMER 3500 KVA INPUT VOLTAGE 11 KV OUTPUT VOLTAGE 415 V, Earthing Arrangement Copper plate earthing with 50 kg of chemical earthing Transformer - 3500 KVA TECHNICAL SPECIFICATION- 1- Capacity : 3500 kVA, 2- Input Voltage : 11 KV, 3- Output Voltage : 415 V, 4- Number of Phase : 3 Phase 5- Applicable Standard : Standard, 6- Number of Winding : 02 Nos, 7- Installation Type : Outdoor, 8- Cooling Type : ONAN, 9- Terminal Arrangement : Bare, Bushing for HV Side & 10- Cable Box for LV Side., 11- Vector Group : Dyn 11, 12- Ambient Temperature : 50° C, 13- Temperature Rise of Oil : 40° C, 14- Temperature Rise of Winding : 45°C, 15- Impedance : 6.25% (Subject to +/-10% Tolerance), 16- Transformer Oil : "A Grade" tested & certified as per IS:335 Standard., 17- No Load Losses : As per IS Standard, 18- Full Load Losses : As per IS Standard, 19- Copper : Pure Electrolytic Grade, 20- Tapping Mode 01 Nos - Rotary Type Off Circuit Tap Changer (OCTC) with Locking Arrangement & Tap Indication., 21- Basic Insulation Leve for HV : 75 KV peak/28 KV RMS, 22- Basic Insulation Level for LV : -/3 KV RMS, 23- Tapping Range +5% to -5% in Steps of 2.5% by Off Circuit Tap Changer (OCTC)., (A) EARTHING ARRANGEMENT (1) Copper Plate Earthing 600x600x6 mm with 50 Kg of Chemical Compound depth around 10 Meter with Testing Pit. (2) GI Plate Earthing 600x600x6 mm with 50 Kg of Chemical Compound depth around 4 Meter with Testing Pit. (3) COPPER STRIPS 50*6 (4) GI STRIPS 50*6 MAKE PREMIUM, (B) CABLES AND ACCESSORIES (1) 3 C x 240 Sqmm AL Armoured HT Cable (2) JOINT KIT (3) 3.5 C x 400 Sqmm AL Bid Number : GEM/2025/B/6768705 Dated : 17-10-2025 Bid Document 1/19
10 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.