Part-I:- Design, supply, erection, testing, commissioning, infringement removal of 25KV AC, Single Phase OHE in connection with 25 KV AC OHE modification work in Manmad Yard, in connection with doubling work between Daund- Manmad (A- Route), Part-II:-Design, supply, erection, testing, commissioning & infringement removal work in connection with Manmad SSP shifting work in connection with doubling work between Daund- Manmad (A-Route), Part-III :- Design, supply, erection testing and commissioning of 25 KV, Single Phase, AC OHE works, in connection with Provision of 25 KV / 240 V, 25 KVA AT & 50 KVA AT supply for work, in conection with 3rd line between MMR-JL in Bhusawal division of Central Railway, Part-IV:- Design, supply, erection, testing & commissioning of 25 KV AC, single Phase OHE including modification in existing OHE, due to construction of ROB at LC- 98 , LC- 88, LC- 93A & LC- 94 & Removal of LT, HT infringement in connection with construction of the above ROB/RUB work & Electrification of 2nos. SUB WAY, in Bhusawal division of Central Railway, Part-V:- Design, supply, erection, testing & commissioning of 25 KV AC, single Phase OHE including modification in existing OHE in downside of Nandgaon yard in connection with leftover work of Manmad-Jalgaon 3rd Line, Part-VI:- Design, supply, erection, testing & commissioning of 25 KV AC, single Phase OHE including modification in existing OHE due to 9 nos. new FOBs in connection with 3rd line between MMR- JL.Part-VII:-Temporary Lighting & Emergency power supply arrangement during Non-Interlocking works at site as per the requirement of Railway, in connection with 3rd line between MMR-JL.
Helical Spring Inner for Bolster (BLC) to RDSO Drg. no. CONTR-9404-S/7, Alt. 8, item no. 2. Material and specification confirming to RDSO specification no. WD-01-HLS- 1994, Rev. 5 of Dec 2024.
NLB/HS Pedestal jaw liner size 3 X 38 x 67 mm as per FIG. 31 of RDSO CASNUB Bogie manual no. G.95 [Rev. 2] of Jun 2026, Material and specification as per Fig. 31.
1. RED LED Signal lighting units with built in current Regulator retrofittable in existing CLS Unit as per RDSO Specification RDSO/SPN/199/2025 Rev 1.2 with amendment 1 or latest for Main Signal Unit. 2. YELLOW LED Signal lighting units with built in current Regulator retrofittable in existing CLS Unit as per RDSO Specification RDSO/SPN/199/2025 Rev 1.2 with amendment 1 or latest for Main Signal Unit. 3. GREEN LED Signal lighting units with built in current Regulator retrofittable in existing CLS Unit as per RDSO Specification RDSO/SPN/199/2025 Rev 1.2 with amendment 1 or latest for Main Signal Unit
HVN-66 INSULATING LINER FOR USE WITH PSC SLEEPER TO DRAWING NO. RT-2496 SUITABLE TO 60 KG (UIC) / 60E1/ 52 KG RAILS DRW: (RDSO) RT 3706-3708 SPEC: (RDSO) IRS Specification T-44, 2025, Third revision
SF6 gas with Cylinders (net weight of gas 11 kgs in each non-returnable cylinder) SF6 gas
1)The testing setup for the Auxiliary Converter (BUR) consists of the following items: i) 6 channel Digital isolated oscilloscope with 8 Slot Modular Mainframe, supports 32 Analog (Plug in modular inputs for analog channels). Qty-01 no. & 7KV Peak differential probe, 5KV RMS, 70 MHz Bandwidth with battery & adapter operation. Qty: 03 Nos. Technical details shown in Annexure-I. One set consists as 02 items in 04 Nos. 2) Laptop intel core i7 or core ultra 7 or higher window 11 professional or higher, DDR4 RAM or higher 16 GB or higher, SSD 1024 GB or higher. Qty-04 Nos. Technical details shown in Annexure-III.
LED ILLUMINATED PUSH BUTTON LATCHING TYPE FOR FLASHER LIGHT WITH 2 N/O CONTACT BLOCK AND 24 VOLT LED INDICATION SUPPLY. COMPLETE BODY OF NON- METAL MATERIAL TO HSC ARTICLE NO. 2XVLDLSTPPN-MVBS OR EQUIVALENT. ONE SAMPLE TO BE APPROVE BEFORE BULK MATERIAL SUPPLY
WBI_2_Board of Part no.FT0029675-101 for Faiveley make WSP system in LHB Coaches
Supply & commissioning of equipment assembly setup with AC fitting as per Annexure-A & Annexure- B. Note: - the firm will submit the warranty certificate, test certificate and calibration certificate along with the material.
SUPPLY, INSTALLATION, COMMISSIONING & TESTING OF THE OHE POWER PRESENCE/ABSENCE INDICATOR FOR EXISTING INSPECTION PIT & TESTING AS PER TECHNICAL SPECIFICATION ANNEXURE 'A' ATTACHED. ACCEPTABLE MAKE: ASIAN, TECHFUTURE, SAMADHAN ONLY. ONE SET CONSISTS AS 13 ITEMS AS PER ANNEXURE 'B'.
Proposal for hiring of companion for the patrolling duty as companion to main patrolman in section under ADEN Katol & ADEN (South) Nagpur Sub division.
Dismantling, Removal, Cleaning, Attending, Assembly and Painting of Wheel Sets, Wheel Discs, Suspension Tubes, Bearings, Main Gears, Drive Assemblies, Brake Discs, Axle Box Assemblies and Associated Components of Conventional and Three Phase Locomotives at ELW/BSL
Laying , Termination and associated for 48 fiber connectivity for OPGW in Service Building for CSMT-Kalyan Section of Mumbai Division.
Provision of dual detection of Track Circuit in the balance section of East Section of Mumbai division.
Provision of Catering Services General Minor Unit (GMU) earmarked for General category at Akola Railway Station on PF No. 2/3, BD end near Coach Indicator No. 7.
Improvement of structural life of bridges by Railbearer replacement, replacement of corroded rivets & structural repairs of various track girder bridges in DW-BSR, CSMT-CLA & KYN-LNL section over Mumbai division.
Improvement of structural life of Composite ROBs and Steel TGBs by Conventional Painting of various bridges in KYN-IGP section of Mumbai division. (10 Bridges)
Improvement of structural life Composite ROBs and TGBs by Metallising and Conventional painting over various sections (DW-PNVL ,MNKD-PNVL, KYN-LNL) of Mumbai division. (8 Bridges)
Epoxy based painting and repairs of PSC Bridges, Br. No. 42/1 UP &DN on MNKD- PNVL and Raoli Junction flyover (Bridge No 10/2) in VDLR-MM chord section of Mumbai division.
Improvement of structural life of track Girder bridge by Sand Blasting & Metalizing of Wadibunder Viaduct br. on CSMT-CLA (HB) line.
Set of zinc plated & passivated Mild Steel Hex head bolts fully threaded of various sizes conforms to IS -1364 (Part 1): 2023 class 8.8 ( 1 set consist of following sizes) 1) M 5 x 35 -20 kg. 2) M 6 x 20 - 20 kg. 3) M 6 x 25 -20 kg. 4) M 8 x 35 -20 kg. 5) M 10 x 40 - 40 kg. 6) M 10 x 60 - 40 kg Total 160 kg. The Hexagonal Head Bolts shall be confirming to IS Specification No.1364 (Part 1) : 2023 which is for "Hexagon Head Bolts, Screws and Nuts of grade A & B " Set
SEALANT PUTTY FOR BONDING METAL SURFACES TO SPECN. ICF/MD/SPECN-114, ISSUE STATUS-01,REV-02
Comprehensive Annual Maintenance, Repair, Servicing, Overhauling, Filtrations of Transformer Oil, Calibration Testing of 33KV/433V Substation Transformer and all other subsidiary equipment of substation including HT & LT panels, HT & LT Power and Control Cable Repair work at Wagon Repair POH Workshop, katamla Road, Badnera, Amravati 444701 for 02 years.
Provision of Catering Services General Minor Unit (GMU) earmarked for (Women) category at Bhusawal Railway Station on PF No. 6 NGP end between COP column No. 25 & 26.
Custom Bid for Services - Comprehensive Annual Maintenance Contract CAMC of Hand Held Terminals HHTs provided to Ticket Checking Staff of Nagpur Division for a period of 2 years Similar Category Customized AMC/CMC for Pre-owned Products
Monthly Basis Cab & Taxi Hiring Services - SUV; 2000 km x 24X7; Outstation 24*7
Custom Bid for Services - Repairs of OHE ON OFF Indication system of Line No 28, 29, 31, 32, 33, 34 & 35 Similar Category Repair, Maintenance, and Installation of Plant Systems/Equipments (Version 2) Repair, Maintenance and Installation of Plant Systems/Equipments
Electrical TRD portion work in connection with launching FOB girders at Washimbe, Pophlaj, Bhalwani & Dhavlas Stations in Solapur Division.
Outsourcing the work of Magnetic Particle Test (MPT), Dye Penetrate Test (DPT) at TMW.
Design, Manufacture & Supply of Semi-Automated Horizontal Radial Clearance Measurement Gauge & Mechanical Comparator for bearing
M.S., black, hex head, round body, without nut, size 20 X 65 mm - shall conform to Item No. 1 of ICF Drawing No. T-0-5-673, Alt. d. The specification of the item shall be as per the drawing, i.e., IS 1364 : Part 2 : 2023 ( ISO 4017 : 2022), property class - 8.8.
A) Improvement to existing boundary wall of Kalwa Carshed (2.5km)B) THK - Repairing works and re-tarring of bitumen roads at 12th Battalion Campus at Thakurli(East) under ADEN(WKS)KYN