Loading…
Loading…
Opening company profile
Loading company metrics, contact preview, and tender history.
Public records across all portals
dc power supply Dc Power Supply ( 20 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FUNCTIONAL Maximum Power (Watt) 120 watts * DC Current Output Rating (Ampere) 0 to 4 * DC Voltage Output Rating (Volt) 0 to 30 * Load Regulation (Voltage) ± (% of output + offset) less than 0.01 +2 (milli volt) * Load Regulation (Current) ± (% of output + offset) less than 0.05 + 1.5 mA * Line Regulation (Voltage) ± (% of output + offset) less than 0.01 + 1 mV * Line Regulation (Current) ± (% of output + offset) less than 0.05 + 0.1 mA * Over Voltage Protection Accuracy +- 0.5 + 0.5 V * Over Voltage Protection less than 10 milli * 1/4 Response Time (milli sec) second Ripple and Noise Voltage (20 Hz to 20 MHz) less than 1 mVrms less than 4 mVpp * . Ripple and Noise Current (20 Hz to 20 MHz) less than 4 milli amps rms * Readback Voltage Accuracy 0.05 + 10 mV * Readback Current Accuracy 0.15 + 5 mA * Read back Voltage Resolution (mV) 1 * Readback Current Resolution (mA) 0.1 * CONSTRUCTIONAL PC Interface USB/GPIB/RS232/LXI * Weight (gms) less than 12 kg * Warranty (Year) 1 1, 2 CERTIFICATIONS Operating Temperature (Degree C) 0 TO 50 C * Gperating Humidity (RH) (%) 95 * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification including environmental tests as under : (a) Dry Heat : For 16 hrs. at a temp. of 55 degree C in accordance with IS:900 0/part-3/section-5/1977 (reaffirmed in 2007). (b) Cold Test : For 4 hrs. at a temp. of -20 degree C in accordance with IS:9000/part-2/sec tion-4/1977 (reaffirmed in 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles of 24 h each at a temp. of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 (reaffirmed in 2007). After environmental Yes * 2/4 conditioning sequence as above and a recovery period of two hours, the instrument shall be checked for complete functional parameters, which should be with in limits.(Test reports are to be furnished when demanded by buyer) Test Report No. UNILINE- 255874 * Test Report Date 25/05/2017 * Name and address of the Lab UNILINE LAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DEEPIKA SHARMA 500043, AIR FORCE ACADEMY DUNDIGAL HYDERABAD 20 30
dc power supply Dc Power Supply ( 20 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FUNCTIONAL Maximum Power (Watt) 120 watts * DC Current Output Rating (Ampere) 0 to 4 * DC Voltage Output Rating (Volt) 0 to 30 * Load Regulation (Voltage) ± (% of output + offset) less than 0.01 +2 (milli volt) * Load Regulation (Current) ± (% of output + offset) less than 0.05 + 1.5 mA * Line Regulation (Voltage) ± (% of output + offset) less than 0.01 + 1 mV * Line Regulation (Current) ± (% of output + offset) less than 0.05 + 0.1 mA * Over Voltage Protection Accuracy +- 0.5 + 0.5 V * Over Voltage Protection less than 10 milli * 1/4 Response Time (milli sec) second Ripple and Noise Voltage (20 Hz to 20 MHz) less than 1 mVrms less than 4 mVpp * . Ripple and Noise Current (20 Hz to 20 MHz) less than 4 milli amps rms * Readback Voltage Accuracy 0.05 + 10 mV * Readback Current Accuracy 0.15 + 5 mA * Read back Voltage Resolution (mV) 1 * Readback Current Resolution (mA) 0.1 * CONSTRUCTIONAL PC Interface USB/GPIB/RS232/LXI * Weight (gms) less than 12 kg * Warranty (Year) 1 1, 2 CERTIFICATIONS Operating Temperature (Degree C) 0 TO 50 C * Gperating Humidity (RH) (%) 95 * Availability of Test Reports from Central Govt/NABL approved ILAC acredited lab to prove conformity to the specification including environmental tests as under : (a) Dry Heat : For 16 hrs. at a temp. of 55 degree C in accordance with IS:900 0/part-3/section-5/1977 (reaffirmed in 2007). (b) Cold Test : For 4 hrs. at a temp. of -20 degree C in accordance with IS:9000/part-2/sec tion-4/1977 (reaffirmed in 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles of 24 h each at a temp. of 40 degree C & 95% RH in accordance with IS:900 0/part-5/section-1 1991 (reaffirmed in 2007). After environmental Yes * 2/4 conditioning sequence as above and a recovery period of two hours, the instrument shall be checked for complete functional parameters, which should be with in limits.(Test reports are to be furnished when demanded by buyer) Test Report No. UNILINE- 255874 * Test Report Date 25/05/2017 * Name and address of the Lab UNILINE LAB * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 DEEPIKA SHARMA 500043, AIR FORCE ACADEMY DUNDIGAL HYDERABAD 20 30
8 more tenders are hidden. Create a free account to unlock the full tender history, filters, and exports.
This profile is built from what portals disclose publicly. Since several states never release bidder lists or quoted prices, it likely understates the company’s true footprint. A tender is counted as won when the company either received the award or stood L1 at financial bid opening, even if the formal award is still pending. TenderKart compiles these public records independently and has no association with any government portal, buyer, or bidder.