function generator Average Turn Over of Last 3 Years 5 Lakh (s) Function Generator ( 4 ) Technical Specifications Specification Specification Name Values Allowed Values MEASUREMENT FEATURES Frequency Bandwidth (Sine Wave) 10 mHz to 25 MHz 10 mHz to 25 MHz Number of channels 2 2 Standard Waveforms Sine, Square, Pulse, Ram p, Noise, Exponentional rise/fall, DC Offset - Band Width of Arbitrary Waveform Generator 10 mHz to 5 MHz 10 mHz to 5 MHz Sample Rate of Arbitrary Waveform Generator (Mega Samples/sec) 50 50, 200, 250, 500, 1000, 2 000 Record Length of Arbitrary Waveform Generator (Kilo Points) 16 16 Waveform Memory of Arbitrary Waveform Generator (Waveforms) 4 - Vertical Resolution 14 - Amplitude Range (at 10mV to 10 V pp 10mV to 10 V pp 1/4 50 ohm impedance) Modulation AM, FM, PM, FSK, Burst, Sw eep - GENERIC Interface USB - Display Type LCD - Display Size 3.9 - Any others features, if applicable NA - ACCESSORIES Details of Standard Accessories To be supplied with the devices Arbitrary/Function Generator Safety and Compliance Instructions; printed document, Documentation CD containing the following PDF documents, Packing list Power cord, specified by country Certificate of calibration; printed document USB cable x 1, Type A to Type B BNC cable x 2 Supplemental Information Sheet For the Peoples Republic of China: China RoHs; printed document Fuse, cartridge; 5 x 20 mm, 0.5 A, 250 V, timedelay Fuse, 1 A, time- delay - POWER SOURCE Power Requirements 230 V +/-10% AC, 50 Hz +/- 3% - OPERATING CONDITION Minimum Operating Temperature 0 - Maximum Operating Temperature 40 - Operating Humidity (RH) at 40 deg C non condensing (%) 80 - SERVICE Warranty 5 5.0 CERTIFICATION & TEST REPORT DETAILS The equipment supplied with calibration certificate yes - conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 no - 2/4 0/part-3/section-5/1977 latest conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no - conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no - Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification yes - Test Report Number and date for the specification test (not a part of biddable parameter) QCC/SI/22 - Name and address of the Lab for the specification test (not a part of biddable parameter) QUALITY CALIBRATION CENTER, 1 AMARNAGAR MAIN ROAD, OPP PERFECT FORGING, MAVADI PLOT, RAJKOT - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Government Polytechnic, Ahmedabad 380015, Ambawadi, Ahmedabad - 380015 2 30 2 Government Engineering College, Dahod 389151, Jhalod Road, Dahod - 389151 2 30 EMD Required No ePBG Required No 3/4
Loading…