Line Intractive UPS with AVR Line Intractive UPS With AVR ( 60 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 0.5/168 0.5/84, 0.5/168, 0.5/400, 0.65/168, 0.65/400, 0.65 108, 0.8/168, 0.8/400, 0. 8/216, 1.0/168, 1.0/400, 1.0/216, 1.0/800, 1.5/80 0, 1.5/600, 2.0/800, 2.0/1 600 Technology MOSFET-PWM MOSFET-PWM, IGBT- PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1, 2 &3 Rated Output (Volt) Single phase sinewave 230v AC, 50Hz Single phase sinewave 230v AC, 50Hz, Single Phase Quasi-Sin-wave 230 V AC, 50 Hz Degree of protection IP-21 IP-21, IP 20 Inverter Efficiency (%) >/= 70% >/= 60%, >/= 70% Warranty for the battery from the date of delivery 1 year - Warranty for Line Interactive UPS 2 Years 1 Year, 2 Years, 5 Years Installation and commissioning No - 1/4 instructions CONSTRUCTIONAL Type of enclosure ABS - AC out put for printer (not through inverter) No Yes, No Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 2 Three pin, 3 Three pin, Hard wiring, Not applicable FUNCTIONAL Total harmonic distorsion (%) </= 40% - Input (Volt) Single phase sinewave(160-280v) - Switching over time (Mili sec) Maximum 10 milli seconds - Overload Time (Minutes) >/= 10 minutes - Load power factor >/= 0.6 - Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%, 50 +/-3 Hz - Overload (%) >/=10% - Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% - Variation on output frequency in battery mode (Hz) </=0.5 - PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 - Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts, the system shall switch over to battery mode Yes - Protection against short circuit of UPS Yes - Protection for over voltage and over load Yes - REPORTS AND Damp heat Test at 45 Yes - 2/4 CERTIFICATIONS degree, RH -95% for 2-cycle as per IS:9000 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes - Cold Test as per IS:9000 pt-2/sec-4 Yes - Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes - Type Test certificate no. and date NTH(SR)/EL/(C)/2017/0 0101A - Name Of Lab NATIONAL TEST HOUSE SR - Address of Lab TARAMANI CHENNAI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Not applicable presently - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Johnson Varghese 695014, Office of the Senior Divisional Electrical Engineer Divisional Railway Manager Office Trivandrum Division, Thycaud, Thiruvananthapuram-69501 4 60 15 EMD Required No ePBG Required No
Loading…